Responds to Nov 1980 Ltr to President Carter Re Containment Structure Cracks at Facilities.No Cracks That Will Leak Radioactivity Exist
ML19340E931
Person / Time
Site: Zion  File:ZionSolutions icon.png
Issue date: 01/02/1981
From: Eisenhut D
Office of Nuclear Reactor Regulation
To: Dudink F
AFFILIATION NOT ASSIGNED
References
NUDOCS 8101160280
Download: ML19340E931 (5)


Text

+,

). Mi ) &< a y

v c

Docket Nos.

295 and 50-304 Mr. Frederick G. Dudink 617 Nordic Court Libertyville Illinois 60048 D' ear !!r. Dudink:

Your note 'to President Ca'rter in mid flovember 1980 on the cracks at the Zica nuclear plant has been referred to this office for response.

Your concern for your safety in light of the November 14-16, 1980 news articles is understandable, but we would like to explain the facts about the " cracks" and how an ongoing study concerning ultimate containment strength may have been misinterpreted.

On June 17, 1980, we held a meeting with the utility in our offices in Bethesda, Maryland. The meeting was to discuss the effects on the containment structure from pressure inside the containment. Our current study referenced a 1973 study on the containment structure in which the Sargent and Lundy Company reported finding fine surface cracks, the widest being 0.002 inches, on the outside concrcte surface. This is the type of fine surface imperfection that occurs i

from thermal and drying shrinkage as concrete sets during construction.

l The 1973 report also measured these surface imperfections while the containment was pressurized to 54 pounds per square inch; there was no change in these imperfections during this or other tests at reduced pressure levels.

l The study that has been going on for the past ten months is also investigating the response of the containment building to higher pressures. Calculations indicate that s,.ress. cracks would first appear in the concrete structure at about 92 pounds per square inch. This is some 40 pounds per square inch greater than we would expect inside the containment with the wore + design basis accident. This is also l

l the type of crack that would be of concern to us since it would be the first indication of significant containment stresses.

It would not, however, be a failure that would release radiation to the atmosphere.

The walls of the containment are 3' 6" thick prestressed concrete, the

' dome is 2' 8" thick prestressed concrete (both heavily reinforced),

and the floor is 9' 0" thick reinforced concrete. The inside of the containment is covered with a 1/4" welded steel plate called the liner.

Our study also indicated that over 140 pounds per square inch inside

............ ~....