ML19340E233

From kanterella
Jump to navigation Jump to search
Slide Presentation Entitled, Revisions to 10CFR55,Operator Licenses
ML19340E233
Person / Time
Issue date: 12/09/1980
From:
NRC OFFICE OF STANDARDS DEVELOPMENT
To:
Shared Package
ML19295E744 List:
References
REF-10CFR9.7 SECY-80-491, NUDOCS 8101060704
Download: ML19340E233 (21)


Text

. _.

~. - - - - - -....

~

OPERATOR QUALIFICATION AND LICENSING REQUIREMENTS FORMAL EDUCATION USA:

HIGH SCHOOL GRAD OR GED CERTIFICATE CANADA:

SECONDARY SCHOOL GRAD OR EQUIVALENT GREAT BRITAIN:

(1) PROFESSIONAL ENGINEER (2) SECONDARY SCHOOL GRAD WEST GER!iANY:

SECONDARY SCHOOL GRAD S103e6o70q

OPERATOR QUALIFICATION AND LICENSING REQUIREMENTS JOB RELATED EXPERIENCE USA:

2 YRS POWER PLANT 1,2 2

1 YR NUCLEAR 6 MOS. ON-SITE CANADA:

2 YRS OF RELEVANT INDUSTRIAL, NUCLEAR OR THERMAL 1 YR AT STATION GREAT BRIiAIN:

(1) PROFESSIONAL Et;GINEERS 2 YRS POST GRAD TRAINING AND OJT (2) SECONDARY SCHOCL GRADS 4.5 YRS POST GRAD TRAINING AND OJT WEST GERMANY:

MECHANICAL OR ELECTRICAL CRAFTMAN OR SEVERAL YRS POWER P 1 YR NUCLEAR 6 M05. ON-SITE U 5pecial Prograts for Pr Critical Applicants.

2) Navy Equivalent

. ~.

OPERATOR QUALIFICATION AND LICENSING REQUIREMENTS TRAINING PROGRAMS USA:

CLASSROOM SPECIFIED: 55.21 AND REG GUIDE 1.8 OJT PLUS 3 MOS. IN CR SIMULATOR CANADA:

6 MOS. OJT PLUS FACILITY SPECIFIED TRAINING PROGRAM APPROVED BY AECB SIMULATOR GREAT BRITAIN:

4 WEEKS PRIOR AT TRAINING CENTER 6 WEEKS ON-SITE 7 WEEKS AT TRAINING CENTER i

i WEST GERMANY:

TRAIllING CT FOR NUCLEAR & CONVENTIONAL.

3 YRS OJT AND TECHNICAL. "KRAFTWERKER"

[

SIMULATOR

,-,e w

--m~-

v--

--,-,,.--en-- - -

m,.

m - re, w - -

-o'+--

-,a

,~v..

OPERATOR QUALIFICATION AND ' LICENSING REQUIREMENTS EXAMINATIONS USA:

NRC ADMINISTERED WRITTEN, ORAL AND SIMULATOR EXAMINATIONS PER 55.21 AND 55.23 CANADA:

6 WRITTEN EXAMS PREPARED BY AECB.

EACH EXAMINATION IS ADMINISTERED AT THE CONCLUSION OF A BLOCK OF TRAINING.

GREAT BRITAIN:

PERIODIC REPORT TO STATION MANAGER NO EXTERNAL OPERATOR LICENSING PROGRAM WEST GERMANY:

UTILITY ADMINISTERED BASED ON FEDERAL GUIDELINES.

WP,ITTEN AND ORAL NO SIMULATOR e

e

,n- - -

m o--

v

--s

.s---

-m.

v w

v-r-w

OPERATOR QUALIFICATION AND LICENSING REQUIREMENTS REQUALIFICATION PROGRAMS USA:

NRC ADMINISTERED WRITTEN, ORAL & SIMULATOR EXAMINATION REQUIRED: LECTURES OPERATING REPORT REVIEWS, OJT & SIMULATOR TRAINING CANADA:

1 ANNUAL SIf1ULATOR EXAMINATIONS REVIEW SIGNIFICANT EVENT REPORTS AND NEW OR MODIFIED OPERATING MANUALS GREAT BRITkIN:

I WEEK EVERY 2 YRS AT TPAINING CT INCLUDING SIMULATOR SERIES OF EMERGENCY EXERCISES PERIODICALLY AT SITE WEST GERt1AriY:

100 HRS PER YR REVIEW PROCEDURES, PLANT SPECIFIC INFORMATION, OPERATING HISTORY SIMULATOR NO GOVT. EXAMS

1) For Pickering Station Only

SENIOR OPERATOR QUALIFICATIONS AND LICENSING REQUIREMENTS FORMAL EDUCATION USA:

(1) HIGH SCHOOL OR GED - PRESENT (2) 60 SEMESTER HOURS OF COLLEGE LEVEL EDUCATION - 1986 CANADA:

(1) SECONDARY SCHOOL GRAD OR EQUIVALENT (2)GRADENGINEERS l

l GREAT BRITAIN:

(1) SECONDARY SCHOOL GRAD (2) PROFESSIONAL ENGINEER WEST GERMANY:

(1) KRAFDIERKER OPERATOR (2) TECHNICAL UNIVERSITY, TECHNICAL HIGH SCHOOL OR ENGINEERING SHC00L GRAD l

SENf0R OPERATOR QUALIFICATIONS AND LICENSING REQUIREMENTS JOB RELATED EXPERIENCE USA:

1,2 (1) 4 YRS AT POWER PLANT 1,2 (2) 2 YRS AT NUCLEAR POWER PLANT 1 YR AS LICENSED OPERATOR 6 MOS. AT FACILITY CANADA:

(1) 10 YRS RELEVANT EXPERIENCE (2) 4 YRS RF".EVANT EXPERIENCE 1 & 2 ONE YR ON-SITE 6 MOS. OJT FOR POSITION i

GREAT BRIT IN:

(1) SECONDARY SCHOOL GRADS i

4.5 YRS POST GRAD TRAINING AND OJT (2) PROFESSIONAL ENGINEERS 2 YRS POST GPAD TRAINING ANC OJT l

WEST GERMANY:

l (1) 6 MOS. AS OPERATOR (2) NONE SPECIFIED

1) Special Programs for Pre-Critical Applicants
2) Navy Equivalent

SENIOR OPERATOR QUALIFICATIONS AND LICENSING REQUIREMENTS TRAINING PROGRAMS USA:

CLASSROOM SPECIFIED: 55.21 - 55.22 & REG GUIDE 1.8 3 MOS. ON-SHIFT SIMULATOR 9

CANADA:

FACILITY SPECIFIED CLASSROOM TRAINING PROGRAM APPROVED BY AECB.

OJT SIMULATOR GREAT BRITAIN:

4 WEEKS PRIOR AT TRAINING CENTER 6 NEEKS ON-SITE 7 WEEKS AT TRAINING CENTER l

l WEST GERMANY:

(1) 1 YR MECHANICAL ENGINEERING FOR NUCLEAR PLANTS (2) POST GRAD EDUCATION & TRAINING TO OBTAIN PRACTICAL EXPERIENCE

t s

SENIOR OPERATOR QUALIFICATIONS AND LICENSING REQUIREMENTS EXAMINATIONS USA:

NRC ADMINISTERED WRITTEN, ORAL & SIMULATOR EXAMINATIONS PER 55.21, 55.22 & 55.23 CANADA:

6 WRITTEN EXAMS PREPARED BY AECB.

EACH EXAMINATION IS ADMINISTERED AT THE CONCLUSION OF A BLOCK OF TRAINING GREAT BRITAIN:

PERIODIC REPORT TO STATION MANAGER NO EXTERNAL OPERATOR LICENSING PROGRAM WEST GERMANY:

WRITTEN & ORAL BY CHAMBER OF INDUSTRY AND COMMERCE l

1 i

l l

l I

.. - ~.

...~._ -....--..-.

f SENIOR OPERATOR QUALIFICATIONS AND LICENSING REQUIREMENTS REQUALIFICATION PROGRAMS USA:

NRC ADMINISTERED WRITTEN, ORAL & SIMULATOR EXAMINATION REQUIRED: LECTURES,,0PERATING REPORT REVIEWS, OJT & SIMULATOR EXERCISES CANADA:

I ANNUAL SIMULATOR EXAMINATIONS REVIEW SIGNIFICANT EVENT REPORTS AND NEW OR MODIFIED OPERATING MANUALS.

GREAT BRITAIN:

1 WEEK EVERY 2 YRS AT TRAINING CT INCLUDING SIMULATOR SERIES OF EMERGENCY EXERCISES PERIODICALLY ~ AT SITE.

WEST _ GERMANY:

100 HRS PER YR v-~g w+

e e

.-,r w-

- n

ll,

u-REVISIONS TO 10 CFR PART 55 ll "0PERATOR'S LICENSES"

!i l

o EDUCATION, EXPERIENCE AND TRAINING OF R0'S AND SR0'S o

SIMULATOR APPLICABILITY

'l o

REQUALIFICATION OF R0'S AND SR0'S i

iI o

CODIFIES PREVIOUS COMMISSION DECISIONS 4

o INCLUDES ADDITIONAL RELATED REQUIREMENTS i

CONDITION OF LICENSE R0 SR0 FAMILIARITY WITil o

10 CFR PART 50.5MW)

CURRENT PLANT CONDITIONS I

12/09/80 g

i

i LIEMS TO CDDJFY PR5VIOUSCOMMISSION DECIS10HS_.

o EXPERIENCE REQUIREMENTS FOR SR0 f

2 YRS.

NUCLEAR POWER PLANT EXPERIENCE INCLUDING SIX MONTilS l

AT THE FACILITY FOR WHICH LICENSE SOUGHT 1 YEAR AS LICENSED R0 3

MONTHS ON-SHIFT TRAINING jt o

THREE MONTHS ON-SHIFT EXPERIENCE REQUIRED FOR R0'S t

o MANDATORY USE OF SIMULATORS IN INITIAL AND REQUALIFICATION TRAINING PROGRAMS AND RECERTIFICATION AFTER PERIODS OF INf.CTIVITY o

NRC TO ADMINISTER ANNUAL REQUALIFICATION EXAMS UNLESS FACILITY LICENSEE l,

DIRECTED TO DO SO o

SCOPE OF EXAMS MODIFIED TO EMPHASIZE THERMODYNAMICS AND HYDRAULICS t

12/09/80 i

IIEMS TliAT G0 BEV0ND OR MODIFY PREVIOUS DE_CISIONS i

i o

EDUCATION REQUIREMENTS FOR SR0 i

i o

EDUCATION AND EXPERIENCE REQUIREMENTS FOR R0

~

o SIMULATOR APPLICABILITY REQUIREMENTS

.o REQUIREMENT FOR FACILITY LICENSEE TO DEVELOP PROCEDURES TO ASSURE COMPETENCY AND KNOWLEDGE OF PLANT CONDITIONS j

l

I

,I i

t j

12/09/80

)

l l

l)

R I

EllllCATION REQlflREMENTS' FOR' SR0_

i ll l!

o 60 SEMESTER HOURS OF COLLEGE -

L5VELCOURSES l

)

MATHEMTICS

{.

C TRY MATERIALS REACTOR THERMODYNAMICS

j l'

FLUID MECHANICS HEAT TRANSFER ELECTRICAL THEORY l

REACTOR CONTROL THEORY i!

i l!

o SAME GENERAL TECHNICAL EDUCATION SPECIFIED FOR SHIFT TECHNICAL ADVISOR i

REGULATORY GUIDE 1.8 RECOMMENDS BS DEGREE FOR SHIFT SUPERVISOR' o

3 r

12/09/80 j

9 l

Y EDijCATION 'AND' ' EXPERIENCE' REQUIREMENTS FOR R0_

o HIGli SCHOOL DIPLOMA OR GENERAL EDUCATIONAL DEVELOPMENT CERTIFICATE o

EXPERIENCE THREE EXPERIENCE IN TESTING, OPERATION AND

,l MAINTENANCE OF POWER PLANTS j.

ONE YEAR EXPERIENCE AT FACILITY FOR WHICll LICENSE IS SOUGHT SIX ' MONTHS AS UNLICENSED OPERATOR AT FACILITY FOR WHICH LICENSE IS SOUGHT

'j i

Ij-6 4

32/09/80 g>-

I i

jl

  • SIMULATOR APPLICABILITY i

e SIMULATOR COMPARED TO FACILITY FOR WilICll LICF.NSE S000llT SAME GENERIC PLANT TYPE (PWR',' DWR') IITGP.)

l!

SAME CONTROL ~ ROOM TYPE (CONVENTIONAL') ADVAtlCED) i SAME TYPE STEAM GEflERATOR (ONCE!TilROUGil') V; TUBE)

SAME NUMBER OF PRIMARY SYSTEM LOOPS

}

I i

e 4

12/09/80 9

==. ur.m_.m 3.g..

7

SUMMARY

OF CHANGES TO 10 CFR 50 AND 55 SECTION CHANGE ADMINISTRATIVEPROCEDURENTOkSSURERO'sANDSR0'SFAMILIARWI i

50.54(w)

PLANT. CONDITIONS 55.4(C)

. DEFINES'(ONE). FACILITY DEFINES NUCLEAR POWER PLANT..(EXCLUDE-. TEST AND RESEARCH) 55.II(H)

)

1

.R0 AND SR0 Muir. MEET. APP.D -(EDUCATION, -EXPERIENCE AND TRAINING REQUIREME 55.10(A) 55'11(c)

LI6ENSE RkQUIRED -FOR.-EAbb..FACILIT'Y-TO..BE OPERATED.

i l

EXAM.TO.TESTAPPd5 CANTS. UNDERSTANDING.THEOR,.Oh.0PERATIONOFTHEFACILI h

j 55.20 55,21.

.. LISTS.EXAMINkTIONTOPICS.FORR0'S LI5TS EXAMINATION TOPICS 50R..SR0'S.

.55.22.,.

1 55,23 INCLUDE $.SSMULkTOR Ilj OPERATING. TEST RECERTIFICATION ON SIMULATOR AFTER l MONTHS INACTIVITY l

12/09/80,f G4 Tl M

55.31(F)

ALL LICENSEES PARTICIPATE IN REQUALIFICATION AND COMPLETE ANNUAL EXAM 55.33(A)(4)

INFORMATION SUBMITTAL WilEN REQUALIFICATION INCOMPLETE-

~

l 55.33(B) l_ICENSEE MUST COMPLETE ONE REQUALIFICATION EXAMINATION 6S CONDITION OF EXTENDING LICENSE PAST EXPIRATION DATE WillLE APPLICATION UNDER LOMMISSION REVIEW l

55.33(C)(2)

PARTICIPATION IN'REQUALIFICATION MANDATORY 55.33(C)(4)

RENEWAL APPLICANTS MUST MEET EDUCATION REQUIREMENTS OF APP 3 t

l' 55.40(C)

ALLOWS REVOCATION DUE TO ANNUAL EXAM FAILURE l

APP A, INTR 0pVCTION, PARAGRAPH si DELETE TEST OF LECTURE SUBJECTS - REFERS TO 55.21 AND 22 APP A, PARAGRAPH 3A CONTROL MANIPULATIONS NUMBER DELETED (RECOMMENDATIONS IN R.G. 1.8)

}*

APP A, PARAGRAPH 3E SIMULATOR USE FOR ABNORMAL, }lNFREQUENT AND EMERGENCY TRAINING AS PART OF

-REQUALIFICATION PROGRAM.

USE OF SIMULATOR NOT OPTIONAL.

i APP A, PARAGRAPH 4A PURPOSE OF ANNUAL EXAM CilANGE FROM:

AREAS NEEDING RETRAINING TO:

VERIFYING 10 CAN OPERATE SAFELY AND COMPETENTLY VERIFYING 3R0 CAN SUPERVISE OPERATION SAFELY AND COMPETENTLY 12 /09/80

' APP B e

REQUIRED EDUCATION, EXPElllENCE AND TRAINING FOR R0'S AND SR0'S t

i e

SPECIFIES TYPE OF SIMULATOR BWR,PWR 1

Ii CONTROL ROOM TYPE f

STEAM GENERATOR IYPE 1

NO OF l.00PS ii j !

I i

i E

i O

I i

i i

i j

s i

4 l

12/09/bo 4

g

e

~; r l

d kc r c,

e eor ul r

l l

Na s

o L

o Eawn n

tt l

e r

T o

aoo a

ro sn r

ru l s a

L l

N h

rmPi t

t ie O

Td um c

et tri

'c i td r

eI ma WS f saaS n

a a e

  • d o rc is l arre-t ear n t s

eoC SE df" P r 'P y

arTel n Cvn T.K n M A

a a e

r cC pcO r

n l

T P

y o U" lou go o

a a

i n u s

yt f

T d

n1 a N.

nC t

e m rw rv t

q S

n.

o3 rt s

i a

He oo f

E od cenro nA l

id' t i 0v"gtG i

i u

l ed t S t

W ca ci v a TM a r f',*r m y

s isI i UBU" W

'fl

?

0e l e l

er erel t a r o SG' TSP 16 ra g ei 1R I i i

l f

p t e3,tS n

.l ir e

sn s

r n

n ao t

r d

rl d

g e

o e

rt ri Ta eS,

ea a

n t

i c

e a

e r

er r

i n

t i

l m

n G nT G.

n e.

a L

t u Et s

l d

i C

t a.

l aT a

S r

am a

n i

n o

nd orJ

. r g.

o d

i y o

o l

E o

Ea oGD T

n o

t-e sS cy i

r h

i t

a n

r nl t

N h

r o

Tg el a

'FI l

c lG ctd

.t n.

n ga r

i a

S a

T Ssn a

e l

t e

t 2i rc e

r p

n ntJ oa t

a.

r o

O n

d ei p

I o

y osD yP r

i i o r

g o

S T.

p m

e yu md O

i rl Eo R

i r

sPd asn i

e l a t

s d

s n

d ri r

n t.

R ar ec i,

t" D

s a

nn t

vn f r a"

n T

e n

esa nT n P

O a.

c re o

Ei oe A

r o

f r o i ts' er N

P i w t ('

s s s c 5. a E

oT 1 iI" d

kt s R.

mc e

r k rk k e

r n

f P

S P2I S4T ee e e.

op x eC es,

et e e is Eg e

ie s9 A E" s

Wn W W rn n

Wa rs s

)

)

)

)

1 2

1 2

e ea oi n el i

f

(

(

(

(

4C 6 1 P.M Ns

'Sc II f

E

~

H I

ji t

tn R

d l

i e

e8

~

R la iC 8 d s

(

I t

E

'v fE C ef r

R iA E ro s og y

i c

A e l

u

~

ey tk n pn l

E a

pb y sc o ei n

f q

l N

i Rt O

i S

B i o 1

t a

d nl r

r o

t ye d lB a tr n

N e

n ne o

E s

tv t da

.i ep i

C u

io s

d d

l r a A m vO t

I e

n ip p

f d

a E a

L cp e so e

s d

t l

aa r i n

E te D

M ir I

N h te F

P n

o ni S

f s

n m

no i

r af g

A tl amn t

o ci n

l sa s oi f

'C o

veo ur mt s n

t id i

A o

l l g a tu e

a f o r

l h

ehi l

l if e

f c

lTt Po x al f

i S

e a

r E nc u n k

A Rrt iP in t

n n' r c

T o

io.

i i

l r

n no,

l S

C S

P y

oS r

f ng n

'e aCo f

I a

o rt n t t

z n

ws l

wel r

F d

aa

,i a t Eei l

i hn a ef a o

l A

n se snl l

rl r foi u r hti ui u

F IF" c

T c'T a m W c a n vdn o

l atr n ena 2f1 6T 5 6 eat A Raf,

)

lu r

1 l

1

(

e R

'S O

TA l

A R

r E ~

P ~

l r l

o A

ae a

gt r

na e

O W

rP 1

D D

il r

tu P

2

.s 4

am n

3 n

ri r

s D 5

no e

eS os 5

ei 1

1p ft W

t E

tt 1

t nfA n

G R

ta n

C in io sa e

d ri e

ri sf mc t

_, ',I r 2

al n elrE ri e m

d Wt o

l e

n it l

a t

i I

a d

n f

dx u

dn u gpl eE3 C

ei t.

op a rA v i

r m cs,

A a a

2 g

S r

g e c

s r

ea ew P

i U G P

t e8 o er ri p

H t o5 e

t x Le l

u l n ras S1 st5 R

sE i

l a q e

i v

ac E oi ee-3 i a oa wl n me r

nld d

nr : e,

ii un e,

io dRg ct y h c ocO od s o l

i mt e n ei v ci Pu ui u t ama Sf N.

rul a ai f

da rtl pr a i r!

SC M i

i Al AS1 i

s s

sG P l

u o l.

)

s c

a ht rro s

u 2

e Cp qpe i

aa i m Cd ar TTl Rn5 p

Ri eef

)

)

216 CR B S Na5 S

MS RRT 1

2 l e l

i l e i C.

l f

S M

E A

C R

N G

E O

I R

R P

S t

E f

M N

0 P

l X

A 0

R l

E G

i v

AC D

O S

R N

A C

U E

M D

T P

O I

I E

E A

T L

G T

F S

I L

E N

A L

I y

N A

L K

w.

~

M R

C A

R I

IM I

U N

t 8

I l

o 0

A A

D Q

r X

E E

E

.t T

E M

R II f

J R *

~

n.

51;., '..,

..,'. ) /:,,.,. i

I i

i' /'

a'-

e y' F.. k f' g *., j '..

y I.,

l-

{. fh #

i

['

~

f!?l ifil(l

I

.f

12/9/80 SENIDR OPERA 103 quA(IIIEAll0fl5 AND (IEEMSING REQUIREftENTS l

WEST CERtt/MT

.,1

- - - 10 u n 5 3 -~ j CPEAT ORITIAN

. _. CANADA tl5A Revision PQ* p..#

i

. ITEM (1) Secondary School Grad. 6r Equiv-(1) Secondary School Grad tr (2) inhntul Unlver-q.. y.

j(1) litgh School or GED - Present alent J{,

TORMAl. EDUCAiloft 1 rE 5

IC C'I "

(I) 6 Mos..*

. ? ;r 1.2 (1) 10 Trs Relevant Expertence (1)Secondar School Grads Operator (1) 4 Yn Power Plant 4.5 Trs ost Grad.

[.

M' (2) 4 Trs Relevant Expertence Training and DJT

+2) None Spect fled JOB RELATED EXPERIENCE (2) 2 Yrs at Nuclear Power Plant g

e....

I O I IO" "t Gra!

i n-6 s a ac ty ing and OJT (1) 1 Tr Hechanical

')h Facility Specified Classtcom Train-lear Plants 4 Hevks Prior at Training Engineering for Nuc-

~-

i :.y.

Classroom specirled: 55.21 -

Center inn Program Approved by AEE8

  • I [
  • h **~
g'

1 RAINING PROGRAPI 55.22 A Rep Guide 1.fi 6 Weeks On-Sit'e 1.-

IMT 3 Mos. On-Shift 7 Weeks at. Training Center obtain Practical Expe simulator

$1amlator

.i.

6 Writte'n Exams Prepand by AEC8

. Periodic Report to Station Written & Oral by

-s Chader of Industry NRC Administered Written. Dral A Manager

'"OI"""Cb gggg7gg3 Simulator Examinations Per 55.21.

Each Examination is Aantnistered No External operator Licen-

,I..

55.22 A 55.23 at the Conclusion of a 81ock of t

sing Program Training.

i 'j }.,. '

.o Tes e

Not Hentioned Not 11entioned Speelffed Reg Guide 1.134

< i-EDICAL I

!! Week Every 2 Trs at Tral vi -

Annual Simulator Examinations

lnq u Inch dino SI M ator 100 Hn per Tr ItRC Aihinistered Written. Oral &

'I 51mulato'r Examination Review significant Event Reports

' Sert'es of Emergency Ener-REQUAI.!FICATI0ff PROGRNIS and New or flodified Operating clses Periodically at Site Reguln d: Lectu es' Operating fianuals.

'.:.G Report Reviews. (k1T A Simulator Exercl,es, s

All Start as " Assistant Shif t Superilsor l

1) Shift Supervisor only operating Engineers".

Must be Grad.

1) Special Programs for Pre.

Engineer

> Critical Appilcants

2) Plchring My Move to " Assistant Charge REMARKS Engineer" A "Shlf t Charoe
2) Navy Equivalent

. Innineer". (Duty Authortred,

fj,q re -..

.+.e-.

.