_m 9

Form N AC418 U.$. NUCLE AA REGULATC AY COMMIS$loN CERTIFICATE OF COMPLIANCE to A 71 For Radroactive Materials Packages 1.tal Certificate Nurneer 1.tb) Revision No.

1.(c) Pacuace toentification No.

1.(d) Pages No. 1.te) Total No. Pages 6375 10 USA /6375/B( )

1 2

3. PAEAMSLE 3.!a)

This certificate is assuso to satisfy Sections 173.393a.173.394.173.335, are 173.396 of the Cecartment of Transoortation Nazarcous i

Materiais Requiat ons (d9 CFA 170189 and 14 CF A 103) ano Sections 146-19-10a and 146-19-100 of the Ceoartment of Transportation Oangerous Cargoes Aegulations 146 CF A 146-149), as amerced.

3.tol The oa:maging and contents cescrioec in stem 5 betow. meets the safety standarcs set fortn in Sucoart C of Titte 10. Coce of 8eceral Aegulations. Part 71. "Pacmaging of Aacicactive Materials for Transport ano Transoortation of Racioactive Vatenal Under Certain Conciteons."

3.{c)

This certificate does not relieve the consignor from coracliance with any requirement of the regulations of the U.S. Ceoartment of Transportation of other applicaole regulatory agencio.. including the government of any country through or 'nto wheen the package i

mill be transcorted.

3.
  • hts certificate is issuec on tne tasis of a safety analysis reoort of tne Deckage oesegn or apolacation-3.la) 8eeparec Dy (Name and scaress):

3.(b)

Title and centification of report or apohcation:

Chem-Nuclear Systems, Inc.

Chem-Nuclear Systems, Inc. applicatica P.O. Box 1866 dated November 26, 1979.

Bellevue, WA 98009 71-6375 3.fel Docket No.

a. CCNCITIONS This certificate is cond tenal upon the fulfilling of the recuirements of Succart D of 10 CF A 71, as sop #icacie, and the conoitions specified in item 5 below.
5. Description of Pactacing are Autnorizea Contents. Mocet Numoor. Fissaie Class. Otner Conoitens. ard Aeferences; (a) Packaging (1) Model No.:

CNS 4-45 (2) Description A lead shield shipping cask, encased in mild steel on the outside and stainless steel on the inside.

The cask is cylindrical in shape, 173-1/8 inches long and 42-1/2 inches in diameter for all of its length except for a distance of 31-5/8 inches at each end which is 40-1/2 inches in diameter.

The principal shielding consists of 6-1/4 inches of lead.

~

A nine-inch thick-impact limiter is attached to both ends of the, cask with four of the twelve, 1.25-inch cover bolts (each end of the cask has a cover).

The impact limiters are constructed by welding a bundle of 2-1/2-inch, 13 gage tubing between 1/4-inch SS plates and enclosing the bundle with a 1/16-inch SS shell.

The cask cavity is 26 inches in diameter by 159 inches in length.

The net weight of the cask is 57,050 pounds.

The gross weight is 67,050 pounas.

8101050/2.7

Page 2 - Certificate No. 6375 - Revision No 10 - Docket No. 71-6175 5.

(a) Packaging (Cont'd)

(3) Drawing The Model No. CNS 4-45 shipping cask is constructed in accord with the Battelle Memorial Institute Drawing No. 9123-6PB-0001, Rev. B.

l (b) Contents (1) Type and form of material Solid nonfissile irradiated hardware and neutron source components.

(2) Maximum quantity of material per package Maximum weight of contents, including any container, shall be 10,000 pounds.

As needed, appropriate component spacers shall be used in the cask cavity to limit movement of contents during accident conditions of transport.

6.

The cask shall be shipped dry.

7.

Pipe plugs may be used as seals for the pressure gage, vent and drain lines.

8.

Prior to each shipment, tha packaging lid silicone 0-ring shall be inspected.

The 0-ring shall be replaced with a new silicone 0-ring if inspection shows any defects or every twelve (12) months, whichever occurs first.

9.

The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR s71.12(b).

10.

Expiration date:

November 30, 1981.

REFERENCE Chem-Nuclear System, Inc. application dated November 26, 1979.

FOR THE U.S. NUCLEAR REGULATORY COMMISSION O

Cnarles acDonaid, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety DEC 2 0 EM Date:

l