Text

-

. - - _ =

j

}

O Form N8C 618 U.S. NUCLE AR REGULATORY COMMISSICN 37 gh3I "2

CERTIFICATE OF COMPT.l ANCE 73 For Raoscactive Materials Packages i

1.'a l Certificate Nymmer 1.!D) Revision No.

1.t c) 'actage scentification No.

1,(d) Pages No. 1.iel Total Ns. Pages 900i 4

USA /9007/B( )

1 2

2. P A E A*.'8 LE
2. a4 This certificate is issued to satisfy Sectens 173.09;a.173.394.173.39s and 173.096 of tee Department of Transoortation mazarocus Vateriais Aequtai or's (49 CFR 170189 and 14 CFR 1031 and Sections 146-19-10a and 146-19-100 cf tme oepartraent of Transportation Dangerous Cargoes Regulations 146 CFR 146-149), as areenced.

2.:t }

The 04:kagine and contents cescribed in item 5 betow, meets the safety standares set forth in Sueoart C of Title 10, Coce of Federal Eegulations. Part 71, Pacmaging of Raceoactive Materials for Transport and Transoortation et Racicactive Material Uncer Certain conoitions.-

2.(c)

This certificate oors not relieve tne consignor from comoliance wetn any recuirement of itse regulations of tne U.S. cesartment of Transportation or other acclicable regulatory agencies enducing tf*e government of any country terougn or into wrnen the package well be transoortec.

3. Ns certificate es issued an tee basis of a safetv analysis recort of the package deseg's or appiecation-3.(31 P coares o.Name one adcren):

3.(b)

Title and edertificatea of report or acolication:

Automation Industries, Inc.

Automation Industries, Inc. application dated P.O. Box 245 July 25, 1973, as supplemented.

Phcenixville, PA 19460 3.ies cocket No.

7]-g007 4 CONDITICNS This certificate is concitonal upon the fulfilling of the recuirements of Sucoart D of 10 CFR 71, as aoolicaolo, and the concitens specif>id in stem s Deiow.

5. Descrioteen os Pacmaging anc Autnorized Contents, Mooet Numoer, Frssile Class. Ctner Concitons. and

References:

(a) Packaging (1) Model No..

520 (2) Description A uranium shielded ' radiographic device consisting of an ovated 5" OD x 1/8" thick steel pipe welded to two, 10 gage end plates. An opening on each plate gives access to the "S"-shaped titanium tubing which houses the source capsule, source cable assembly, and the end plug.

The two end openings are closed with threaded end caps.

A lock mechanism is provided at the source cable attachment.

Gross weight of the package is approximately 40 pounds.

(3) " Drawings The packaging is constructed in accordance with Automation Industries, Inc.

Drawing Nos. 200-520-001, Rev. A; 100-520-001/012;,200-520-011; 100-520-014; and 100-520-013.

8103030/G5

Page 2 - Certificate No. 9007 - Revision No. 4 - Docket No. 71-9007 5.

(b) Contents (1) Type and form of material i

Iridium-192 as a sealed source which meets the requirements of special form as defined in 10 CFR $71.4(o).

i (2) Maximum quantity of material per package 120 curies 6.

The source shall be positiored within the titanium tubing by a source cable assembly which meets the parameters shown in Automation Industries, Inc. Drawing No. SK-500-SU.

7.

The nameplate shall be fabricated of materials capable of resisting the fire test of 10 CFR Part 71 and maintaining its legibility.

]

8.

The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR 671.12(b).

9.

Expiration date:

December 31, 1985.

REFERENCES Automation Industries, Inc. application dated July 25, 1973.

i Supplements dated: November 28, 1973; and February 18 and April 4,1975.

FOR THE U.S. NUCLEAR REGULATORY COMMISSION J

l M S&

N i

Charles E. MacDonald, Chidf Transportation Certification Branch Division of Fuel Cycle and Material Safety Date:

C 2 31939 J