hh f'fffb b=
a-+ia NUCLEAR ENERGY
,' ': a' t R.= * \\ 'a. g sl.;=Ujajb i
ENGINEERING GENERAL ELECTRIC COMPANY, P.O. BOX 460, PLEASANTON, CALIFORNIA 94566 DIV1SION i
i October 8,1980 Mr. C. E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety U.S. Nuclear Regulatory Commission Washington, D.C. 20555 Re ferences:
(1) Certificate of Compliance No. 5980 (2) Application for IAEA Certificate of Competent Autnority, General Electric Model 600 Shipping Container, 5/14/80 (3) Letter, Fees Management Branch to G. E. Cunningham, 5/29/80 (4) Letter, G. E. Cunningham to C. E. MacDonald, 5/21/80 (5) Letter, C. E. MacDonald to G. E Cunningham, 6/13/80
Dear Mr. MacDonald:
In order to resolve the differences between Certificate of Compliance 5980 and our application for IAEA certification of the Model 600 for limited con-tents pursuant to the 1973 IAEA regulations, General Electric hereby re-quests that Section 5.(b)(2)(i) of Certificate of Compliance 5980 be amended as foliows:
5.(b)(2) Maximum quantity of material per package Plutonium in excess of twenty (20) curies per package must be in the form of metal, metal alloy or reactor fuel elements, and (i) For the contents described in 5.(b)(1)(1) the maximum decay heat not to exceed 600 watts and the fissile content not to exceed 500 grams of U-235, 300 grams U-233, 300 grams Pu, or a prorated quantity of each such that the sum of the ratios does not exceed unity. When the contents of this paragraph are in the form of irradiated reactor fuel, the fuel shall have been cooled for a minimum of 90 days, and no more than 1000 Ci of noble gases shall be available for release from the fuel rod plenums.
The cask shall be leak 3
tight to l' x 10-3 atm-cm /sec under normal conditions of operation.
The amended pages for IAEA certification are attached.
For purposes of clarification two other minor changes should be made to the Certi ficate.
These are:
,n.;-*m l
Lauw.)
802222e gh
Mr. C. E. MacDonald October 8,1980 1.
The eighth sentence of Section 5(a)(2) shculd be modified in part to read:
i "For wet shipments the drain line is closed with a plug which has a melting temperature of 2000F.", and 2.
A sentence should be added to Section 7 to read:
"For dry shipments the drain line is closed with a solid stainless steel pipe plug."
The purpose of these changes is to recognize that the low melting point plug was intended for wet shipments only.
An amendment fee has been-requested by the License Fee Management Brarich (Ref. 3), and a check for this fee has been forwarded to them under separate Cover.
Sincerely, 0;icaal Signed py "G. E. Cunninc. ham" G. E. Cunningham Senior Licensing Engineer
/11-attachments
i j
l ATTACHMENT A l
REVISIONS TO APPLICATION FOR IAEA CERTIFICATE OF COMPETENT AUTHORITY, 5/14/80
l l
l l
Section II - Packaging and Package Design Requirements (continued) f l
Specific Additional Requirements (continued).
240 The maximum surface temperature of the Model 60? package has been estimated at 1610F (720C) under normal conditions of transport l
(decay heat plus solar radiation absorbed).
t 241 Not applicable - no liquid authorized.
Section III - Exemptions - No exemptions authorized.
l Section IV - Activity 1.imits The contents will be limited to solid radioactive materials in Certified l
Special Form containment er as irradiated reactor fuel with the maximum decay heat not to exceed 600 watts and the fissile content not to exceed 500 grams of U-235, 3G1 grams U-233, 300 grams Pu, or a prorated quantity of each such that the sum of the ratios does not exceed unity. When the contents of this paragraph are in the form of irradiated reactor fuel, the fuel shall have been cooled for a minimum of 90 days, and no more than plenums
' The cask shall be leak tight to 1 x 10 gase frors the fuel rod 1000 Ci of noble gases shall be available for rel atm-cm /sec under normal 3
conditions of operation. Plutonium in excess of twenty (20) curies per package'must be in the form of metal, metal alloy or reactor fuel elements.
Section V - Controls for Transport and Storage in Transit Mixed Packing l
501 Mixed packaging is not authorized.
502 The painted exterior surface of the package is designed to be easily decontaminated so the nonfixed radioactive contamination can be kept below the levels specified in Table XI, IAEA Section V.
l-503 The Model 600 package is categorized after loading in accordance with the surface radiation and transport index measured prior to consignment.
504-509 See paragraph 503, and 510-513.
510-513 The package ~will be labeled as required by IAEA and USD0T regula-l tions.
1 514 The gross weight of the Model 600 package is marked in lbs. and kilograms on the nameplate.
1 51 5 Not applicable to Type B packages.
GC