.a AR:ar 1
UNITED STATES OF AMERICA
==
2 NUCLEAR REGULATORY COMMISSION 3
4 e
5 h
AFFIRMATION SESSION d
6 80-48 e
g 7
8 e
d 9
Room 1130, f
1717 H Street Northwest y
10 Washington, D.C.
E 5
11 Friday, October 31, 1980 g
12 s
i-13 The Commissioners met at 2:04 p.m.,
pursuant to E
14 notice.
- a 2
15 PRESENT:
5 J
16 JOHN AHEARNE, Chairman.
E d
17 JOSEPH HENDRIE, Commissioner.
l d
E 18 PETER BRADFORD, Commissioner.
5
[
19 PRESENT FOR THE OFFICE OF THE SECRETARY:
3n 20 SAMUEL CHILK.
21 PRESENT FOR THE OFFICE OF GENERAL COUNSEL:
22 LEONARD BICKWIT.
=-
23,
24
(:......
[{(fb i
-ooo-25 ALDERSON REPORTING COMPANY. lNC.
n-
.=
- 4 DISCLtIMER 21s is an u=officia.L
- :anscrip: of a. =aeti=g af :ha Uni:ed States Nuclear Regulatory Cc dssica held on 10 31-80 in da Cet=rission's offices at 1717 E Street, N.
W., Washington, D. C.
na =ee:ing was open :o public attendance and observa:1cn.
This. ::anscrip has co: been reviewed, cc: ee:ed, or edi:ed, and l
ir =ay contain i= accuracies.
Tha ::a= scrip: is is ended solely for general d #c:=a:1cua.L purposes.
As provided by 10 C71 9.103, 1: is so: part. of :he for=al or i=for=al record of decisics of the =a::ers discussed.
Expressic=s of opd d cu in dis ::anscript da no necessarily reflec: fi=al dete adticus or beliefs.
No pleading or other paper =ay be. filed with the Cc:=:issien in any proceedi=g as the resul: of or addressed. to any s:stement or argu=ent ec :21=ed herein, excep as the Cec =ission =ay au:horize.
n-1 oa o
g" l
_~
M o Mja h I
l
~
\\
1 e
O 9
9, e
~
~'
2 1
PEQQ((QlEQg 2
CHAIRMAN AHEARNE:
The first item on the Commission's 3
agenda this af ternoon is a series of affirmation items.
E 4
Sam.
e 5
SECRETp.Y CHILK:
The first is SECY-A-80-146, revised 5
Q.-laut % f-8 6
order in Tyron,jlNo.
1.
The Commission unaniscusly has approved
.O N
8 7
an order to defer revocation of the construction permit for l
8 Tyrone Energy Park and denies the request of two South Dakota d
a 9
commissions:for a hearing.
io 10 Would you please affirm your votes?
E 5
11 COMMISSIONER BRADFORD:
Aye.
E d
12 CHAIRMAN AHEARNE:
Joe?
Ec d
13 COMMISSIONER HENDRIE:
Aye.
e a
- 3 E
14 CHAIRMAN AHEARME:
Aye.
N 2
15 SECRETARY CHILK:
The second is SECY-A-80-152, S
j 16 certification to the Commission of request for free transcripts
- r5 6
17 in Lacrosse show-cause proceeding.
The Ccmmission has unanimously 5
5 18 approved the memorandum and order which grants;the request of
=H
[
19 the Licensing Board to provide procedural assistance to 5
20 intervenors in this proceeding.
21 Would you please af firm your votes?
22 CHAIRMAN HENDRIE:
Aye.
23,
COMMISSIONER HENDRIE:
Aye.
24 COMMISSIONER BRADFORD:
Aye.
25l SECRETARY CHILK:
The third is SECY-80-456, advance l
)i ALDERSON REPORTING COMPANY. INC.
j_
....a
... =.
~
3 1
notification to covernors of transportation of nuclear wastes,
[;
2 including spent fuel.
The Commission, by unanimous vote, has 3
approved the proposed amendments for 10 CFR Part 73 and 71, as 4
recommended by the Staff and modified by the General Counsel's e
5 memorandum, to provide advance notification to states of nuclear b
8 6
waste transportation for all wastes, including spent fuel that eWg 7
must be shipped in Type B containers.
A 8
8 Would you please affirm that vote.
n d
c 9
CHAIRMAN AHEARNE:
- Aye, i
h 10 COMMISSIONER HENDRIE:
Aye.
i5 5
11 COMMISSIONER BRADFORD:
Aye.
c5 12 SECRETARY CHILK:
That, Mr. Chairman, concludes h
13 the affirmation.
g
=a a
14 CHAIRMAN AHEARNE:
All right.
Thank you.
w 2
15 (Whereupon, at 2:06 p.m.,
the meeting was 5
J 16 concluded.)
2 d
17 l 5
B E
18 5"
19 8n 20 21 22 23,
24 25 ALDERSON REPORTING COMPANY,INC.
g::.
NUCLEAR REGULATORY CO.'C4ISSION This is to certify that the attached proceedings before the c
. COMMISSION MEETING in the matter of:
Affirmation Session 80-48 Date of Proceeding:
October 31, 1980 Docket !!ueber:
Place of Proceeding:
Washington, D.
C.
were held as herein appesrs, and that this is the original transcript thereof for the file of the Cecmission.,
Ann Fdley Cfficial Reporter (Typed) e Official Reporter ( bgnature) l J
_a
0' UNITED STATES October 7, 1980 NUCLEAR REGULATORY COMMISSION SECY-80-456 4
WASHINGTON, D. C. 20555 CONSENT CALENDAR ITEM For:
The Commissioners From:
John G. Davis, Director, Office of Nuclear Material Safety and Safeguards Executive Director for Operationh b
Thru:
Subject:
ADVANCE NOTIFICATION TO GOVERNORS OF TRANSPORTATION OF NUCLEAR WASTE INCLUDING SPENT FUEL Puroose:
To consider the issuance of proposed amendments to comply with certain provisions of the Nuclear Regulatory Commission Authorization Act fcr Fiscal Year 1980 (P.L.96-295).
Category:
A policy matter requiring Commission approval.
Issue:
Section 301 of the NRC Authorization Act, for Fiscal Year 1980 (enacted as Public Law 96-295 on June 30, 1980)
- provides, "The Nuclear Regulatory Commission, within 90 days of enactment of this Act, shall promulgate regulations providing for timely notification to the Governor of any State prior to the transport of nucTear waste, including spent nuclear fuel, to, through, or across the boundaries of such State.
Such notification requirement shall not apply to nuclear waste in such quantities and of such types as the Commission specifically determines do not pose a potentially significant hazard to the health and safety of the pe'cl i c. "
This mandate raises the following issues:
(1) The
)
quantities and types of nuclear waste that should require prior notification; (2) The method of notification that I
should be provided to the State Governor; (3) The infor-mation to be provided in the notification; (4) The need to issue a proposed rule for public comment; and (5) The need for state governors to protect sensitive safeguards information.
j l
Di ments of radioactive waste
"'-~
disposal, including waste DUPLICATE DOCUMENT for consolidation of loads, Entire document previously Co entered into system under:
Jo ANOhh[
h 42-C.
No. of pages:
42
.