Responds to NRC Re Violations Noted in IE Insp Repts 50-010/76-08,50-237/76-08 & 50-249/76-08.Corrective Actions:Future Environ Monitoring Repts to Contain Brief Explanation for Elevated Reading at Onsite Station 2
ML19340A807
Person / Time
Site: Dresden  
Issue date: 06/28/1976
From: Bolger R
COMMONWEALTH EDISON CO.
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML19340A806 List:
References
NUDOCS 8009040631
Download: ML19340A807 (3)


Text

'

s.

C:mm:nw;;lth ~1irn

,q one First Nationat Pt.

Chicago, litinois j

(

Address Reply to: Post Othce Box 767 Chicago. Ilknois 60690 June 28, 1976 Mr. James G. Keppler Regional Director - Region III U.S. NRC 799 Roosevelt Road Glen Ellyn, Illinois 60137

Subject:

Dresden Station Units 1, 2, and 3 IE Inspection Reports 50-10/76-08, 50-237/76-08, and 50-249/76-08 NRC Docket Nos. 50-10, 50-237, and 50-249

Dear Mr. Keppler:

Enclosed is the response to subject IE Inspection Reports transmitted by Mr. Allan's letter of June 7, 1976.

Neither this letter nor the inspection reports contain proprietary information.

Please direct any additional questions to this office.

Very truly yours, l

/

R.

L. Bolger Assistant Vice President Enclosure e

~'

p /

8009040 3

'.)

NRC Dockst Nos.

50-10 q

50-237 50-249 DEFICIENCY - Thermoluminee,7nt Dosimetry Discussion Following an inspaction on May 5-6, 10-11, and 18, 1976, by Dr. M. J. Osstmann of the NRC, Dresden was cited with one deficiency item.

Contrary to Appendix A, Tech Spec 6.6.C.2.s.(10),

Dresden did not provide an explanation in the July-December,1975 Semi-Annual Report of the slightly elevated results reported for TLD's at Onsite Station No. 2.

The elevated TLD results were mentioned in section 5.1 paragraph 3 (page 30) of the Semi-Annual Report.

However, discussions with Dr. Osstnann i.1dicated that the discussion was not an adequate c'xplanation of why the reading was high.

~

Corrective Action Onsite Station #2 is located about 1/4 mile NE of the

.w Unit 1 turbine building.

At this distance, some elevation in readings could be expected due to gamma shine from N-16.

This elevation is very slight as can be seen from the July to a,

December 1975 Semi-Annual Report.

The elevation ranges between 1 and 3 mrem /uk (

.02 mrem /hr) and is not evident at offsita stations.

sp-

.I Due to this problem, in April 1969, a second set of ion chambers were placed behind a 1/2" lead barrier set approximately' 12" from the chambers in the direction of the Unit 1 turbine building.

This' reduced the excess radiation level by approximately a factor of two.

l p-.

j n

O These data and the purpose of the shielded / unshielded dosimeters were discussed with the NRC (then AEC) in a meeting in Bethesda on January 26 1971.

The elevated readings at Onsite Station #2 have been mentioned in Semi-Annual reports since then, but were not explained in detail since it was felt that this reading represented a routine result, rather than an unusual measurement or deviation.

Future Environmental Monitoring Reports-will contain a brief explanation for the elevated reading at onsite station #2.