ML19339D023

From kanterella
Jump to navigation Jump to search
Final Deficiency Rept Initially Reported on 810129 Re Addition of nonsafety-related Instrumentation in NSSS Cabinets W/O Installation of Necessary Isolation Devices for Separation
ML19339D023
Person / Time
Site: Summer 
Issue date: 02/09/1981
From: Nichols T
SOUTH CAROLINA ELECTRIC & GAS CO.
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
10CFR-050.55E, 10CFR-50.55E, NUDOCS 8102170025
Download: ML19339D023 (2)


Text

. _ - _.

_=

wo.

a I

e n

4 SOUTH CAROLINA ELECTRIC a gas COMPANY l

.,o,,,a......

CotumelA, SouTu CanouNA 29218 we,p.f. iI. Esc.,,

February 9, 1981 ug.. c.aw..

4 Mr. James P. O'Reilly, Director U. S. Nuclear Regulatory Commission Region II, Suite 3100 101 Marietta Street, N. W.

Atlanta, Georgia 30303 4

i i

Subject:

Virgil C. Summer Nuclear Station Docket No. 50/395 Reportable Substantial Safety Hazard No Isolation Device for Field Circuit Nuclear Eng. File 3.1051

Dear Mr. O'Reilly:

+

On January 29, 1981, a substantial safety hazard as defined by 10CFR21 was reported to Mr. John Rausch at the NRC Region II Office. The item involved the addition of a non-safety related instrumentation loop in the Nuclear Steam Supply System protection cabinets without installing the necessary isolation i

devices for separation. Details are given on the attachment.

The item is being reported under our 10CFR50.55(e) procedure. This is con-sidered a final report on the matter.

Very truly yours, r

T. C. Nichols, Jr.

l JAW:TCN:glb Attachment cc:

V. C. Summer w/o attachment J. L. Skolds-G. H. Fischer w/o attachment B. A. Bursey T. C. Nichols,'Jr. w/o attachment O. S. Bradham E. H. Crews, Jr.

H..E. Yocom

0. W. Dixon, Jr.

R. A. Wiesemann C. A. Price Document Management Branch i

D. A. Nauman (55e/21/LER.Only)

W. A. Uilliams, Jr.

I6E'(Washington)

/

R. B. Clary ISEG gf

[

A. R. Koon NPCF/Whitaker A. A. Smith File

_j//

H. N. Cyrus J. B. Knotts.Jr.

1 4

i 8102.1700M p

. =_

= _ _ _. - _. _ _ _. _

l t

i 10CFR 21 - SUBSTANTIAL SAFETY IIAZARD 1.

Name and Address of Reporting Individual James A. Wactor i

South Carolina Electric and Gas Company P. O. Box 764 i

Columbia, South Carolina 29218 i

2.

Identification of Basic Component Nuclear Steam Supply System (NSSS) Protection Cabinet 3.

Identification of Firm Supplying Component Westinghouse Electric Corporation i

4.

Nature of Defect, Substantial Safety Hazard Created, and Evaluation The architect-engineer requested the manufacturer to relocate a balance of plant (BOP) instrument loop in the NSSS protection cabinets because:

of a space problem. In making this change, the isolation normally pro-vided in the protection cabinets was not added. This lack of separation could have permitted a fault in a non-safety related control signal cir-cuit to propagate to the protection circuits.

i 5.

Date Information of Defect Was Obtained January 14, 1981-6.

Number and Location of Defect

{.

There were two instrument loops involved in one cabinet.

7. ' Corrective Action The loops are being removed from the protection cabinets and placed in BOP i

cabinets.

8.

Advice to Purchasers or Licensees None.

.i