ML19339C501

From kanterella
Jump to navigation Jump to search
Submits Info Re Environ Qualification of safety-related Equipment,In Response to NRC .One Environ Qualification Test Planned for Peach Bottom,W/Pertinent Info Encl.Info for Limerick Will Be Provided 801128
ML19339C501
Person / Time
Site: Peach Bottom, Limerick  
Issue date: 11/12/1980
From: Kemper J
PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC
To: Eisenhut D
Office of Nuclear Reactor Regulation
References
NUDOCS 8011180497
Download: ML19339C501 (2)


Text

Su - 22 7

.i ! f d#.

go_. 3 %2 353 PHILADELPHIA ELECTRIC COMPANY 2301 M ARKET STREET 4

P.O. BOX 8699

~

PHILADELPHIA. PA.1910s JOHN S. MEMPER v ec t-en tstD ENT November 12, 1980.I

' ~ * ~ ' " ' ' * " " * " " * "

Pr. Darrell G. Eisenhut, Director Division of Operating Reactors U.S. Nuclear Regulatory Ccamission Washington, DC 20555 Sub, ject : Environmental Qualification of Safety-Related Equipment Re: Correspondence dated October 1, 1980 D. G. Eisenhut to All Licensees of Operating Plants and Applicants for Operating Licenses and Holders of Construction Permits

Dear Mr. Eisenhut:

The reference letter requests information relative to environmental qualification tests to be conducted within the next two years on equip-ment used or to be used in our facilities. We have conducted an investiga-tion for Peach Bottom APS which has revealed that only one environmental qualification test is presently planned. The pertinent information for this test is provided on Attachment A.

We will conduct a similar investigation for Limerick Generating Station qualification tests, and will provide the requested information by November 28, 1980.

Sincerely, f $~ M L_

s

/

Attachment

\\

k (

80111en yy

~

l Attachment A 1

Equipment description - Fluid flow detection system Manufacturer

- NDT International, Inc.

Model

- NDT 781 rev. B sensors NDT 400A preamplifiers NDT 10hD fluid flow detectors (with count accumulator option)

System

- Main Steam and Feedwater System Peach Bottom Units 2 and 3 hnetion

- Win provide Safety / Relief Valve position Test Location

- Wyle Labs Huntsville, AL Schedule

- Program (final submittal) - 11/15/80 Start test - 11/15/80 Program (finalapproval)-12/1/80 Cognicant Licensee Contact - Wes Bowers (215) 841 h629 WJB:LCY 11/3/80

\\

1 1

n-.

.., -