pn ;*h q#o UNITED STATES 4
8
~g g
NUCLEAR ' REGULATORY COMMISSION g
g WASHINGTON. D. C. 20555 a%
/
- *.e 007 31 1980 FCTC: RHO 71-0164 Massachusetts Institute of Technology ATTN: Mr. Lincoln Clark, Jr.
138 Albany Street Cambridge, MA 02139 Gentlemen:
We have evaluated your revised quality assurance program, SAR Chapter 11, sub-mitted with your August 5,1980 letter to satisfy the requirements of 10 CFR H71. 51.
It is the staff's position that the description of the quality assurance pro-gram for packaging and transportation of radioactive material include a complete discussion of how the applicable requirements of Appendix E to 10 CFR Part 71 will be satisfied. Even though some of these requirements may be covered in Technical Specifications and other government regulations, they should be includ-ed in the quality assurance program. Accordingly, please revise Chapter 11 of the SAR to address the enclosed request for additional information and submit seven copies of the revised program within 60 days following receipt of this letter.
If you have any questions regarding this request, please feel free to contact Mr. Jim Conway at (301) 492-7741.
Sincerely, Charles
. MacDonald, Chief Transportation Certification. Branch Division of Fuel Cycle and Material Safety, NMSS
Enclosure:
Request for Additional Information l
5011170 W
- MASSACHUSETTS INSTITUTE OF TECHNOLOGY (71-0164)
Request for Additional Information 1
1A. Provide an organizational chart (s) which identifies the organizational elements which function under the control of the QA program.
2A.
Describe the QA responsibilities of each organizational element identified in the response to question.lA.
3A.
Identify the level of management that is responsible for establishing MIT's QA policies, goals, and objectives 4A.
Describe the qualification requirements for the position of Director of Reactor Operations.
5A.
Provide a statement that designated QA individuals have the responsibility and authority, delineated in writing, to stop unsatisfactory work and-control further-processing, delivery, or installation of nonconforming material.
8A.
Describe how disputes involving quality, arising from a difference of opinion between designated QA/QC personnel and other department. personnel, are resolved.
9A.
Provide a statement that training and experience for all QA functions will be required and accomplished in accordance with established. procedures.
11A.
Provide a statement that individuals or groups responsible for design verifica-tion are other than the original designer and the designer's imediate supervisor.
In exceptional circumstances, the designer's immediate supervisor can perforn, the verification provided:
(1) The supervisor is the only technically qualified individual.
(2) The need is individually documented and approved in advance by the supervisor's management.
(3) QA audits cover frequency and effectiveness of use of supervisors'.as design verifters to guard against abuse.
13A.
Provide a statement that procurement documents identify the applicable 10 CFR Part 71, Appendix E requirements which must be complied with and described in the supplier's QA program. This QA program or portions thereof shall be reviewed and concurred with by qualified personnel prior to initiation of activities affected by the program.
14A. ~ Provide a statement that procurement documents identify the documentation (e.g.,
drawings, specifications, procedures, inspection and fabrication plans, inspec-tion and test records,-personnel and procedure qualifications, and chemical and i -
physical test results of material to' be prepared, maintained, and submitted to the purchaser for review and approval.
15A.
Provide a s.tatement that procurement documents identify those records to be retained, controlled, and maintained by the supplier, and those delivered to MIT. prior to use or installation of the hardware.
O r
w.
- -. ~,,
.,-n
a l
, 1 i
16A.
Provide a statement that procurement documents contain MIT's right of access to supplier's' facilities and records for source inspection and audit.
22A.
Provide a statement that measuring and test equipment is identified and trace-able to the calibration test data.
23A.
Provide a statement that measuring and test instruments are calibrated at speci-fied intervals based on the required accuracy, purpose, degree of usage, stability characteristics, and other conditions affecting the measurement.
24A.
Provide a statement that measures are taken and documented to determine the validity of previous inspections performed when measuring and test equipment is found to be out of calibration.
25A.
Provide a statement that reference and transfer standards are traceable to nation-ally recognized standards; or, where national standards do not -exist, provisions are established to document the basis for calibration.
28A.
Provide a statement that departure, arrival time, and destination of a package will be established and monitored to a degree consistent with the safe transpor-tation of the package.
29A.