[. p rir
. UNITED STATES 8
'n NUCLEAR REGULATORY COMMISSION REGION lli i
Q 799 ROOSEVELT ROAD
\\
' GLEN ELLYN,lLLINOIS 60137 o
OCf 6 1980 State of Illinois Department of Public Health ATTN:
Mr. Gary N. Wright, Chief Division of Nuclear Safety 535 West Jefferson Street Springfield, IL 62761 Gentlemen:
The enclosed IE Supplement No. 2 to Bulletin No. 79-0C, htled " Environmental Qualification of Class IE Equipment" was sent to the licensees listed below on October 1, 1980:
_ ACTION American Electric Power Service Corporation Indiana and Michigan Power Company D. C. Cook 1, 2 (50-315, 50.% 6)
Commonwealth Edison Company Dresden 3 (50-249)
Consumers Power Company Palisades (50-255)
Iowa Electric Light & Power Company Duane Arnold (50-331)
Northern States Power Company Monticello-(S0-263)
Prairie Island 1, 2 (50-282, 50-306)
Toledo Edison Company Davis-Besse 1 (50-346)
Wisconsin Electric Power Company Point Beach 1, 2 (50-266, 50-301)
Wisconsin Public Service Corporation Kewaunee (50-305)
INFORMATION Cincinnati Gas and Electric Company Zimmer (50-358)
Cleveland Electric Illuminating Company
' Perry 1, 2 (50-440, 50-441) 801107t00W cec <
State of Illinois,
Commonwealth Edison Company
-Braidwood 1,.2 (50-456, 50-457)
Byron 1, 2 (50-454, 50-455)
Dresden-1, 2 (50-10, 50-237)
LaSalle 1, 2 (50-373, 50-374)
Zion 1, 2 (50-295, 50-304)
Consumers Power Company Big Rock Point Midland I, 2 (50-329, 50-330)
Dairyland Power Cooperative LACBWR (50-409)
Detroit Edison Company Fermi 2 (50-341)
Illir.ois Power Company Clinton 1, 2 (50-461, 50-462)
Northern Indiana Public Service Company Bailly (50-367)
Public service of Indiana Marble Hill 1, 2 (50-546, 50-547)
Union Electric Company Callaway 1, 2 (50-483, 50-486)
Sincerely, t
len Pappa, Chief Administrat ve' Branch
Enclosure:
IE Circular No. 80-22 cc w/ encl:
Mr. D. W. Kane, Sargent & Lundy Central Files Reproduction Unit NRC 20b AEOD R
T esident Inspectors, RIII.
- a m
y
-47 9
SSINS: 6820 Accession No.:
8008220241 IEB 79-01B, Supple. 2 UNITED STATES NUCLEAR REGULATORY COMMISSION
,yy D,,9 OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.
20555 3 &,g g September 30, 1990 1
IE Supplement No. 2 to Bulletin 79-018: ENVIRONMENTAL QUALIFICATION OF CLASS 1E EQUIPMENT Enclosed are the generic questions and answers which resulted from NRC/ Licensee meetings in NRC Regional Offices during the week of July 14, 1980 regarding environmental qualification of Class 1E equipment in use at power reactor facilities.
These answers address specific questions asked during the meetings.
Due to the generic nature of some of these questions, the staff is issuing them as a bulletin supplement.
The regional meetings highlighted the fact that in some cases, the scope and depth of the 79-018 review was not clear to licensees.
Theist,re, these answers may affect your 79-01B submittal.
These submittals are required by a separate order to be completed by November 1, 1980.
Some answers given in Supplement No. I to IEB-79-01B are superseded by these answers.
For example, in Bulletin Supplement No.1, issued on February 29, 1980, the answer to question No. 5 specified that TMI lessons learned squipment was not included in the review.
However, due to the extension of the response date from April 14, 1980 to November 1, 1980, this equipment is now being addressed since its installation is either complete or required before the issuance of the February 1,1981 SER.
(See Question No. 21 of this Supplement.)
No specific response is requested by this Supplement; however, all answers contained in the enclosure to this Supplement should be carefully reviewed and considered for applicability in your response to IEB 79-01B.
IE Bulletin No.79-01B was issued under a blanket GA0 clearance (B180225 (R0072); clearance expired July 31, 1980) specifically for identified generic problems.
Supplement No. 2 to Bulletin 79-01B is for information, hence no GA0 clearance is required.
Enclosures:
2.
Generic Questions and Answers to IEB-79-01B and Memorandum and Order (CLI-80-21) dated May 23, 1980
.