(g) i f-s YANKEE ATOMIC NUCLEAR POWER STATION l::

r.

ff0NT11LY STATISTICAL REPORT 77-10 FOR TifE f!0NTil 0F OCTOBER, 1977 e

I e

801106o Prf

APPENDIX B

--~

DOCKET NO.

50-29 UNIT YANKEE RONE DATE 771104

=.y COMPLETED By E. C. TARNUZZER TELEPil0NE

. (617) 366-9011 X 276

[

.. =::

AVERAGE DAILY UNIT POWER LEVEL il MONTil OCTOBER, 1977 h.

l' DAY AVERAGE DAILY MWe-net DAY AVERAGE DAILY MWe-net

g..

1 145 16 147

[j 2

146 17 147 3

146 18 147 4

146 19 147 5

146 20 148 I

6 146 21 148 148 145 22 7

145 23 148 8

I43 148 9

24 146 148 10 25 146 148 11 26 145

'148 12 27 108 148 13 28 146 29

- I48 14 146 148 15 30 148 31 i.

l

DOCKET NO.

50-29 DATE. 771104 UNIT NAME YANKEE R0WF OPERATING PLAKr DATA COMPLETED BY E. C. TARNUZZER TELEPl!ONE (617) 366-9011 X 276 2PERAllNG SIAIUS 1.

REPJ)RTING PERIOD:

OCTOBER 1977 GROSS liOURS IN REPORTING PERIOD 745 600 MAX.. DEPEND. CAP. (MWe-NET) 175 2.

CURRENTLY AUTil0RIZED POWER LEVEL MWt 175 DESIGN ELECTRICAL RATING (MWe-NET) 85'6 509 MWt 3.

POWER LEVEL TO WilICli RESTRICTED (IF ANY):

4.

REASONS FOR RESTRICTIONS (IF ANY):

LINEAR llEAT GENERATION RATE LIMIT AS DEFINED IN 10 CFR 50, APPENDIX K

~

1111 S CUMULATIVE MONTi{

YR-TO-DATE TO DATE

~

745 5,223 122,621 5.

Il00RS REACTOR WAS CRITICAL 0

0 0

6.

REACTOR RESERVE SliUTDOWN 110URS 745 5,109 118,422 7.

110URS GENERATOR ON-LINE 0

0 0

8.

UNIT RESERVE SilVTDOWN 110VRS 9.

GROSS TilERMAL POWER GENERATED (MWil) 373,612 2,760,608 62,659,780 10.

GROSS ELECTRICAL PONER GENERATED (MWil)116,061 856,722 19,255,350 109,018 803,557 18,024,975 11.

NET ELECTRICAL POWER GENERATED (Mkil) 100.0 71.6 81.3 12.

REACTOR SERVICE FACTOR 100.0 70.8 80.7 13.

REACTOR AVAIL.\\BILITY FACTOR 100.0 70.0 79.6 14.

UNIT SERVICE FACTOR 100.0 71.9 15.

UNIT AVAILABILITY FACTOR 83.6 62.9 71.9 16.

UNIT CAPACITY FACTOR (USING MDC) 83.o 62.9 71.9 17.

UNIT CAPACITY FACTOR (USING DESIGN MWe) 0.0 1.9 1.5 IS.

UNIT FORCED OUTAGE RATE 19.

SIPJTDOWNS SCliEDULED TO BEGIN IN NEXT 6 MONTilS (STATE TYPE, DATE AND DURATION TWO WEEEEND OLTTAGES SCllEDULED FOR JANUAMf, 1978, FOR OPERATOR OF EACli): TRAINING AND LICENSING EXAMS - DATES LATER.

{

UMT NA%

t a. _. -

2....

,N),

DATE 771104 COMPLETED BY E. C. TIRNUZZER APPENDIX D TELEPllONE (617) 366-9011 X 276 UNIT ShW D0h3S AND POWER REDUCTIONS OCTOBER 1977 REPORT MONE MET 110D OF TYPE.

DURATION SHUTTING DOWN F-FORCED IRTE S-SCIEDULED (HOURS)

REASON (1)

TIE REACTOR, (2)

CORRECTIVE ACTIONS /C05NENTS 771013 F

A 1

9 IIOUR LOAD REDUCTION TO MINIMUM LOAD (1541) TO REPAIR DRAIN LINE ON II.P. WRBINE CASING.

' NARY:

PLANT OPERATED AT 15% DERATE FOR APPENDIX K CONSIDERATIONS FOR ENTIRE MON'III.

Rev'. 10/75

_. ~. _ -..

' NRC pC'mM 195 U.S. NUCLE An AEGULAfonY COCSSioN OoCKET NUMBEn

~-

fC-JG 12 736

{,'

"""7 pgg y

NRC DISTitlBUTION ron PART 50 DOCKET MATERIAL TO:

t ; '.OM:

DATE OF DOCUMENT Yankee Atomic Elec. Company 11/3/77

^

N. R. C.

Westborough, Mass.

DATE RECElVED D. E. Moody 12/5/77 2O TTE R O N OTO RIZ E D PROP INPUT FORM NUMBER OF COPIES RECEIVED C oaisiN AL h LASSiriE D TCC*v g

CE5CRIPTICN ENCLOSURE October 1977 Letter trans the folleving:

Monthly Report for Plant & Co=ponent Operability & Availability.

This Report to be used in preparing Gray Book by Plans & Operations.

FLtd;T NAME:

Yankee Rowe (1-P)

(4-P)

RJL 12/6/77 lEOCL FOR ACTION /INFORMATION I IGC W/3 CYS FOR ACTION i

/*

INTERNAL DISTRIBUTION I

l v.e.; e Lies.J