ML19339B038

From kanterella
Jump to navigation Jump to search
Notification of 801112 Meeting W/Util in Bethesda,Md to Discuss Cycle 5 Reload Analysis
ML19339B038
Person / Time
Site: Calvert Cliffs 
Issue date: 10/27/1980
From: Chang Li
Office of Nuclear Reactor Regulation
To: Clark R
Office of Nuclear Reactor Regulation
References
NUDOCS 8011060210
Download: ML19339B038 (2)


Text

pn Lth 8

q'o UNITED STATES g

E' NUCLEAR REGULATORY COMMISSION p,

E WASHINGTON, D. C. 20555 5

0 f

%......i October 27, 1980 Dock ~et No. 50-317

( ;

J,

~!

MEMORANDUM FOR: Robert A. Clark, Chief Operating Reactors Branch #3, DL FROM:

Chang-Yang Li, Project Manager Operating Reactors Branch #3, DL

SUBJECT:

FORTHCOMING MEETING WITH BALTIMORE GAS AND ELECTRIC COMPANY (BG&E) ON RELOAD REVIEW 0F CALVERT CLIFFS UNIT 1 Date and Time:

Wednesday, November 12, 1980 10:00 AM Location:

Room 6507 Maryland National Bank Building Bethesda, Maryland

Purpose:

A review meeting to ask and to resolve questions on cycle 5 reload analysis for Calvert Cliffs Unit 1

Participants:

NRC BG&E CE L. Phillips J. Lippold P. Kruse D. Fieno E. Trapp L. Kopp S. Gupta V. Panciera S. Diab J. Gutman E. Conner C. Li 6

Chang-Yang Li, Project Manager Operating Reactors Branch #3, DL cc: See back of page 8011060 21O f

,