ML19339A505

From kanterella
Jump to navigation Jump to search
Forwards QA Program Insp Rept 99900114/80-02 on 800812-15.No Noncompliance Noted
ML19339A505
Person / Time
Issue date: 09/10/1980
From: Potapovs U
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Laser R
LAMCO INDUSTRIES, INC.
Shared Package
ML19339A506 List:
References
REF-QA-99900114 NUDOCS 8011040153
Download: ML19339A505 (2)


Text

e O

.. y%

G,%

J y

/

'o, UNITED STATES I f.,., ( i NUCLEAR REGULATORY COMMISSION 3,f~[/

I REGION IV t

[

611 RVAN Pt.AZA oRIVE. SUITE 1000 6

ARLitoToN, TE X AS 76012 q

10 SEP 1980 Docket No. 99900114/80-02 Lamco Industries, Inc.

Atta:

Mr. R. R. Laser President 1596 North Johnson El Cajon, California 92020 Gentlemen:

This refers to the QA Program inspection conducted by Mr. J. W. Sutton of this office on August 12-15, 1980, of your facility at El Cajon, California, asacciated with the fabrication of nuclear components and to the discussion of our findings with Mr. R. Mathiac and members of your staf' at the conclusion of the inspection.

This inspection was made to confirm that, in the areas inspected, your QA Program is being effectively implemented.

The inspection effort is not designed to assure that unique qualicy raquirements imposed by a customer are being implemented; nor to assure that a specific product, component or service provided by you to your customers, is of acceptable quality.

As you know, the NRC requires each of its licensees to assume full responsibility for the quality of specific products, components or services procured from others. You should therefore not conclude that the NRC's inspection exempts you from inspections by an NRC licensee or his agents nor from taking effective corrective action in response to their findings.

Areas examined during the inspection and our findings are discussed in the enclosed report. Within these areas, the inspection consisted of an examination of procedures and representative records, interviews with personnel, and observations by the inspector.

Within the scope of this inspection, we found no instance where you failed to meet NRC requirements.

e

{

8011.040153

z.,

e j

Lanco Industries Inc. *8 In accordance with Section 2.790 of the Commission's " Rules of Practice,"

Part 2, Title 10, Code of Federal Regulations, a copy of this letter together with the enclosed inspection report will be placed in the Commission's Public Document Room. If this report contains any information that you believe to be proprietary, it is necessary that you make a written application within thirty (30) days to this office to withhold such information from public disclosure.

Any such application must include a full stateme2c of the reasons on the basis of which it is claimed that the information is proprietary, and should be prepsred so that proprietary information identified in the application is contained in a separate part of the document.

If we do not hear from you in this regard within the specified period, the report will be placed in the Public Document Room.

Should you have any questions concerning this inspection, we will be pleased to discuss them with you.

Sincerely,

\\

B/

I O

~

s Uldis Pocapovs, Chief Vendor Inspection Branch

Enclosure:

Inspection Raport No.

99900114/80-02 i

i

_.