ML19339A342

From kanterella
Jump to navigation Jump to search
Third Interim Deficiency Rept Re Two of 57 HVAC Damper Actuators 1VG09YB & 1VC26Y,failing Recycling Test.Actuators Returned to Itt.Next Rept by 801113
ML19339A342
Person / Time
Site: Zimmer
Issue date: 10/24/1980
From: Borgmann E
CINCINNATI GAS & ELECTRIC CO.
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
10CFR-050.55E, 10CFR-50.55E, QA-1354, NUDOCS 8011030616
Download: ML19339A342 (2)


Text

e l 1

l y ,

B., ?)

THE CINCINNATI GAS & ELECTRIC COMPANY

.i[p " "' - - y

% =m ~-

CINCINN ATI. OHIO d 52Cl "t" Us**"

October 24, 1980 QA-1354 U. S. Nuclear Regulatory Commission Region III 799 Roosevelt Road Glen Ellyn, Illinois 60137 Attention: Mr. James G. Keppler, Director RE: WM. H. ZIMMER NUCLEAR POWER STATION - UNIT I 10CFR50.55(e) REPORT NO. M DOCKET NO.Er 538, CONSTRUCTION PERMIT NO. CPPR-88, W.0.

, #57300-957, JOB E-6590 Gentlemen:

This letter is submitted as a third interim report on the subject item, pertaining to HVAC damper actuators, which was initially reported by letter on March 12, 1980 and in a second interim report on April 21, 1980.

r The on-site rework program for the ITT Actuators was ccmmenced July 21, 1980 and completed August 4, 1980. We are in the process of reviewing the data pertain-ing to the rework. During the rework program, two of the 57 actuators (IVG09YB and IVC 26Y), failed the recycle test andwcre returned to the ITT factory. The reworked units have been received on site and will be retested.

We have since been informed by the damper manufacturer of a further problem affecting one of the above units (IVC 09Y3). This defect was reported by telephone to Mr. P. A. Barrett of your office on October 14, 1980, as our 50.55(e) case number M-24 and a written interim report will be submitted by November 13, 1980 in compliance with 10CFR50.55(e). The disposition of this item will affect the closure of case number M-14 and we are currently estimating completion by Cecember 31, 1980.

We trust that the above will serve as an acceptable interim repo.O on the So/7 5

/

8011080 Q( $

4 75' " ' **" 'Mt.'" James G. Keppler, Director U. S. Nuclear Regulatory Commission Regicn III October 24, 1980 - QA-1354 Page 2 subject 50.55(e) item.

Very truly yours, THE CINCINNATI GAS & ELECTRIC COMPANY By E. A. BORGMANN SENIOR VICE PRESIDENT JFW;ec .

cc: NRC Resident Inspector Attn: F. T. Daniels ~

Director of Inspection & Enforcemen't',' k/'

NRC, Washington, DC 20555 H. C. Brinkmann S. C. Swain J. R. Schott W. W. Schwiers 4

A TT* N l NOTED l

l I

I I l

l

.mu N 10, l

I l

I I