ML19339A262

From kanterella
Jump to navigation Jump to search
Forwards Inservice Insp Examination Summary, 800818-1013
ML19339A262
Person / Time
Site: Prairie Island Xcel Energy icon.png
Issue date: 10/30/1980
From: Mayer L
NORTHERN STATES POWER CO.
To:
Office of Nuclear Reactor Regulation
Shared Package
ML19339A263 List:
References
IEB-79-17, NUDOCS 8011030467
Download: ML19339A262 (1)


Text

..

MSP NORTHERN STATES POWER COMPANY M I N N E A PO L.l S. M I N N E S OTA 55401 4

October 30, 1980 Director of Nuclear Reactor Regulation U S Nuclear Regulatory Commission Washington, DC 20555 PRAIRIE ISIJ.ND NUCLEAR GENERATING PLANT Docket No. 50-282 License No. DPR -42 Unit 1 Inservice Inspection Summary Report Attached for your review are'four copies of the report. " Inservice Inspection Examination Summary, Prairie Island Nuclear Generating Plant -

Unit 1, August 18 to October 13, 1980, IE Bulletin No. 79-17 and ASME Class 2 Exsminations."

This report is being submitted in accordance with the Prairie Island ASME Code Section XI Inservice and Testing Program submitted to the Commission for review on February 1,1978 (revised through Revision 5 dated September 3, 1980). As noted in that program, submittal of the attached summary is intended to satisfy the inspection reporting requirements contained in IWA-6220 of Sectian XI of the ASME Code.

Detailed inservice inspection reports are available at the plant for review by the Region III Office of Inspecticn and Enforcement.

L 0 Mayer, PE Manager of Nuclear Support Services LOM/DMM/bd cc: J G Keppler (2 copies of attachment)

H Baron, Chief Boiler Inspector, State of Minnesota (1 copy of attachment)

D Wotier, Hartford Insurance (2 copies of attachment)

G Charnoff (w/o attachment)

NRC Resident Inspector (w/o attachment)

)

l i

801103O N'd O

l