Forwards Lll Rept Structural Analysis of Fuel Receiving Station Pool at Nuclear Fuel Reprocessing Plant,West Valley, Ny, UCRL-52575 & .W/O Encls
ML19339A259
Person / Time
Site: West Valley Demonstration Project
Issue date: 09/17/1980
From: Clark A
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To: Vaughan R
AFFILIATION NOT ASSIGNED
References
NUDOCS 8011030454
Download: ML19339A259 (1)


Text

,(

UNITED STATES b

c g

NUCLEAR REGULATORY COMMISSION y

5 r E WASHINGTON, D. C. 20555 s*

E

%.,,,, /

SEP 171980 Docket flo. 50-201 Mr. Raymond 0. Vaughan 135 East Main Street Hamburg, flew York 14075

Dear Mr. Vaughan:

In response to your telephone request on September 15,1980, I am enclosing a copy of the Lawrence Livermore Laboratory report, " Structural Analyses of the Fuel Receiving Station Pool at the fluclear Fuel Reprocessing' plant, West Valley, New York, UCRL-52575.

I also have enclosed a copy of the letter to the West Valley co-licensees, dated May 14,1979, which accompanied the report. The letter also enclosed a copy of review comments by Dr. Wiliiam J. Hall and the NRC staff's evaluation.

Sincerely,

' ^

.:ue

. Thomas Clark, Jr.

Advanced Fuel and Spent Fuel Licensing Branch Division of Fuel Cycle and Material Safety

Enclosures:

As stated 4

  • =,