Text
.
(
.z.
pa ntav
[
UNITED STATES y f;Oq ( j
> s-NUCLEAR REGULATORY COMMISSION
.' i f.
C WASHINGTON, D. C. 20555 5
OCT 7 Eso MEMCRANDUM FOR:
Chairman Ahearne Commissioner Gilinsky Commissioner Hendrie Commissioner Bradford 4
FROM:
Carlyle Michelson, Director Office for Analysis and Evaluation of Operational Data THRU:
J William J. Dircks
'(SIfned) T. A. Rehm Executive Director for Operations
SUBJECT:
AEOD REPCRT ON THE INTERIM EQUIPMENT AND PROCEDURES AT L
BROWNS FERRY TO DETECT WATER IN THE SCRAM DISCHARGE YOLUME Enclosed for your information is a copy of the AEOD report covering the Interim Ecuipment and Procedures at Browns Ferry to detect water in the scram disenarge volume. This report supplements our earlier memorandum on a potential inter-action between the scram and control air systens and our report on the June 28, 1920 Browns Ferry 3 partial scram failure event. Copies of this repo n have also been forwarded to IE and NRR for appropriate action.
I would be pleased to provide any clarification or further information that you may recuire.
,h f A
Carlyle Michelson, Director Office for Analysis and Evaluation of Operational Data
Enclosure:
AECD Report on the Interim Equipment and Procedures at Browns Ferry to Detect Water in the Scram Discharge Volume 8010290 6
- _.