G
'o _],
- or
'.:C 518 U.S. NUCLE AA AECULAToRY COMMISSICN CERTIFICATE OF COMPL!ANCE 10 C A 71 For Aadioactive Materials Pacnages 1.!a) Certificate Nurncer 1.Ib) Revision No.
1.(c) Package Icentification No.
1.(c) Pages No. 1 (e) Total No. Pages 0010 1
eiOS /OndO /D( )
1 1
- 3. P A EAMS LE 2.ta)
This certificate is issued to satisfy Sections 173.393a.173.394.173.39s and 173.396 of the Geoartment of Transoortation Hazarcous Materrass Regu4ations (49 CFR 170-189 and 14 CFR 103) anc Sections 146-19-10a and 146-19-100 of the Ceoartment of Transoortation Cangerous Cargoes Aegulations (46 CF R 146-149). as amended.
3.it)
The Dacmaging and contents descriced in item s cetow, meets the safety standarcs set forth in Subcart C of Title 10. C ide of Federal Aegulations. Part 71, "Packagmg of Racioactive Materials for Transport and Trans&ortation of Radioactive Material Under Certain Conciteens."
3.(c)
This certificate coes not relieve the consH;nor from compliance with any recuirement of the regulations of the U.S. Ceoartment of Transoci.ation or otPer acclicaole regulatory agencies inciucing the government of any country througn or into wnicn the oncmage will me transoorted.
- 3. This ce tificate is issued on the casis of a safety snaivsis reoort of tne cackage cesign or apolication-3.t s Preaa co my ( ame and address):
3.tb)
Titie and identificatio.i of recort or soosication:
General Electric Company General Electric Company application dated P.O. Box 460 February 21, 1980, as' supplemented.
Pleasanton, CA 94566 3.k) occ=et No. 71-9049 4 CCNQiTioNS l
TNs certAcate is cos citional upon the fulfilling of the reouirements of Subpart o of 10 CFR 71, as acolicaole, and the conditions specified in item s cetow.
- s. Oescriction of Pacmaging and Autnoriaod Contents. Moce4 Numoer. Fissile C; ass, other Concitions and Aeferences:
(a) Packaging (1) Model No.: GE-500 (2) Description Steel encased lead shielded shipping cask.
A double-walled steel cylinder protective jacket encloses the cask during transport.
It is bolted to c steel pallet.
The cask is closed by a lead-filled flanged plug fitted i
wit'i a silicone rubber gasket and bolted closure.
The cavity drain line is closed by either a stainless steel or fusible plug (melting point 500 F).
The physical description is as follows:
Cask height, in 29.0 Cask diameter, in 28.0 Cavity height, in
- 7. 0 Cavity diameter, in
- 7. 0 Lead shielding, in 10.0*
Protactive jacket height, in 38.9 P N tective jacket width, in 40.75 Packaging weight, lbs 7,800 8010270/3/-
i
(
F ;E 2 - Cartificate No.
'50,.9 - Revision No. 3 - ccist No. 71-9049 5.
(a) Packaging (continued)
(3) Drawings The packagir,g is constructed in accordance with the following General Electric Company Drawing Nos.:
212E246, Rev. 7 10603855, Rev. 4 10603870, Rev. 11 12904690, Rev. 0 706E790, Rev. 4 (b) Contents (1) Type and form of material
~
(i) Byproduct material meeting special fort, requirements of 10 CFR
$71.4(o); or (ii) Solid nonfissile irradiated metal hardware and reactor control rods (blades).
(2) Maximum quantity of material per package Radioactive decay heat not to exceed 780 watts.
G.
Shoring she11 be provided to minimize movement of contents during accident conditions of transport.
7.
Package contents shall be delivered to a carrier dry.
-8.
Prior to each shipment the silicone rubber lid gasket shall be inspected.
This gasket shall be replaced if inspection shows any defects or every twelve (12) months, whichever occurs first.
Cavity drain line shall be sealed with appropriate sealant applied to threads of pipe plug.
9.
The package authorized by this certificate is bereby approved for use under the general license provisions of 10 CFR 671.12(b).
10.
Expiration date:
July 31, 1985.
i
m.
- - :e-tifi:Ete fio. 9029 - Revision '.'a. 3 - Occket !!c. 71-9029 REFERENCES General Electric Company application dated February 21, 1980.
Supplement dated:
August 26, 1980.
l FOR
'*E U.S. NUCLEAR REGULATORY COMMISSION k'+=k $
=
1 Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety 007 ) 4 7560 Oate:
4 I
i i
1 s
D
?
A j
---w--
,.,e
--y
.,,,-r p
.,,--.w,-py---,
,.m.,
7_w----.,