ML19338F325
| ML19338F325 | |
| Person / Time | |
|---|---|
| Site: | Cooper |
| Issue date: | 08/06/1980 |
| From: | Pilant J NEBRASKA PUBLIC POWER DISTRICT |
| To: | Seyfrit K NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV) |
| References | |
| IEB-80-20, NUDOCS 8010200072 | |
| Download: ML19338F325 (1) | |
Text
-
-=
bccito DAC:ADM:
9' CEitTRAL FILES-PDR:HQ-
"-Q coop t-k.
Nebraska Public Power District
^ * * ?A"l,0 NsIC
._) b A
August 6,~1980-Mr. Karl V. Seyfrit,' Director y /h U.S. Nuclear Regulatory Commission 7
-Office of Inspection and Enforcement Region IV-611 Ryan Plaza Drive Suite 1000 Arlington, Texas ~ 76011
Subject:
IE Bulletin'80-20, Failure of Westinghouse Type W-2 Spring Return to Neutral ~ Control Switches
Dear Sir:
The subject-bulletin requested actions in event Westinghouse Type W-2 control switches are used in safety related systems. 'Th'is letter is written to, inform you that we do not use any of these switches in safety related systems.
It is estimated that 3 manhours were used in this review and preparation of this report.-
If you have any questions regarding this subject, please contact us.
Sincerely, M
J... Pilant Director-of' Licensing and Quality Assurance JMP:LCL:cg cc: 'U.S. Nuclaar Regulatory Commission Office of Inspection and Enforcement Division.of. Reactor Operations Inspection
. Washington, DC 20555 8 010200 0 7 gi