Submits Response to IE Bulletin 80-20 Re Westinghouse Type W-2 Control Switches.About 42 of Subj Switches Are Used in safety-related Sys.Switches Are Tested Monthly & After Each Use
ML19338E775
Person / Time
Site: Prairie Island  
Issue date: 09/12/1980
From: Gilberts D
NORTHERN STATES POWER CO.
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
IEB-80-20, NUDOCS 8010060117
Download: ML19338E775 (1)


Text

6 NSED NORTHERN 5TATES POWER COMPANY M I N N E A PO LI S. M I N N E S OTA 5 5401 September 12, 1980 Mr. James G. Keppler Director, Region III Office of Inspection and Enforcement U. S. Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, IL 60137

Dear Mr. Keppler:

PRAIRIE ISLAND NUCLEAR GENERATING PLANT Docket Nos. 50-282 and 50-306 In response to IE Bulletin No. 80-20, the following is offered:

1.

About 42 switches of the type described are in use in various safety-related systems at this facility.

2.

NSP was notified of the potential problems with these switches via Westing-house correspondence dated July 18, 1980, which included Westinghouse Tech-nical Bulletin NSD-TB-80-9.

In response to the Technical Bulletin, conti-nuity checking was done and the results forwarded to Westinghouse on July 1, 1980. Additional continuity checking has been done; no failures were de-tected. A Special Order was issued that requires testing monthly and after each switch usage.

3.

A Design Change has been initiated which will effect a rewiring of indicating lights that will provide indication of total circuit continuity readily visible to the control room operator. Rewiring in Unit 1 will be completed during the current refueling outage, and Unit 2 during its refueling outage in February 1981.

To date, approximately 250 manhours were spent in the necessary engineering re-quired by this Bulletin. The testing required takes 4 manhours per monthly test.

Modification and testing associated with corrective actions will take about 90 manhours.

Yours truly, D. E. Gilberts i

Vice President Power Production cc:

Mr. G. Charnoff Director, Division of Reactor Operations Inspection Office of Inspection and Enforcement U. S. Nuclear Regulatory Commission Washington, D. C.