'l

  • g

/

TENNEESEE VALLEY AUTHORITY CHATTANOOGA. TENhk$5EC 37401:

400 Chestnut Street-Tower II-Augu9t R6g 9pg. 00 1

Hr. James P. O'Reilly, Director Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Region II - Suite 3100 101 Marietta Street Atlanta, Georgia 30303

Dear Mr. O'Reilly:

OFFICE OF INSPECTION AND ENFORCEMENT BULLETIN 80-1h - RII:JP0 d[-251 -260,_ -29}2-BROWNS FERRY NUCLEAR PLANT - SUPPLEMENTAL

RESPONSE

TVA submitted the response to IE Bulletin 80-14 on July 28, 1980, for the Prowns Ferry Nuclear Plant.

An inadvertent error was made was made in our response to iten A.1 of the subject bulletin.

In addition to the two instances where the ball float assembly was damaged, one instance of a broken rod on the ball float occurred.

This information was telephoned to NRC-0IE representative, Hugh Dance, on August 18, 1980, by Jerry Wills of my staff.

If you have any additional questions, please call Jim Domer at FTS 857-2014.

Very truly yours, TENNESSEE VALLEY AUTHORITY

?

L. M. Mills, Ma ager Nuclear Regulation and Safety Subscribed and sworn t efore i

me this # d It day of

.< e,

1980.

t LLI CW l.

LLLv.A.AA.

Notarj Public g

My Commission Expires 4

2-cc: Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Division of Reactor Operations Inspection Washington, DC 20555 OFFICI AL COPY MOD 250 An Equal Opportunity Employer

--