September 12, 1980 Docket No. 50-184 U. S. Department of Commerce National Bureau of Standards ATTN:
Dr. R. S. Carter, Chief Reactor Radiation Division Washington, D.C.
20234 Gentlemen:
The enclosed IE Information Notice No. 80-32, " Clarification of Certain Requirements for Exclusive-use Shipments of Radioactive Materials," is forwarded to you for information.
No written response is required.
If you desire additional information regarding this matter, please contact this office.
Sincerely, oyce H. Grier Director
Enclosures:
1.
IE Information Notice No. 80-32 2.
List of Recently Issued IE Information Notices CONTACT:
H. W. Crocker (215-337-5217) 8009240281
SSINS: 6370 Accession No.:
/
8006190044 IN 80-32 UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT l
WASHINGTON, D.C.
20555 August 29, 1980 IE Information Notice No. 80-32:
CLARIFICATION OF CERTAIN REQUIREMENTS FOR EXCLUSIVE-USE SHIPMENTS OF RADI0 ACTIVE MATERIALS
\\
Background
In mid-1979 the NRC initiated an enhanced program for inspection of shipments of radioactive materials, including, in particular, low level wastes.
In conjunc-tion with this effort, civil penalties have been assessed for violation of associated regulatory requirements.
IE Bulletins 79-19 and 79-20, " Packaging of Low Level Radioactive Waste for Transport and Burial," issued August 8, 1979 and IE Information Notice 79-21, " Transportation and Commercial Burial of Radioactive Material," issued September 7, 1979, provide background in this regard.
During the past year, this augmented inspection / enforcement program has prompted a number of questions on the proper application of certain regulatory requirements.
These questions involve mainly the problems and deficiencies associated with exclusive use highway shipments of low-level radioactive wastes.
The purpose of this Notice is to discuss the questions and clarify the applicability of certain requirements.
Acolication of 49 CFR 173.393(i) and (j)
Numerous questions involve the application of the limits of radiation levels of exclusive use shipments as prescribed in 49 CFR 173.393(j).
As stated therein, the regulation reads (j)
Packages for which the radiation dose rate exceeds the limits specified in paragraph (i) of this section, but does not exceed at any time during transportation any of the limits specified in para-graphs (j)(1) through (4) of this section may be transported in a transport vehicle which has been consigned as exclusive use (except aircraft).
Specific instructions for maintenance of the exclusive use (sole use) shipment controls must be provided by the shipper to the carrier.
Such instructions must be included with the shipping paper information:
(1) 1,000 millirem per hour at 3 feet from the external surface of the package (close (2) 200 millirem per h DUPLICA' T DOCUMENT the car or vehicle I
Entire document previously f
entered into system under:
CC M%M4 ANo i
N o.
of pages:
3
- 4tl C Fil 173.303(ll-10 mrsm/hr 2 nurm/hr AT ANY POINT 2 m (G It) f a 2 ma Am/h 19 CFil 173.393(jl.10 mesm/hr AT ANY POINT 2 m (G f t!
FilOM Tile VEllTICAL PLANES PilOJECTED.-
I~
FilOM Tile VEllTICAL PLANE PHOJECTED.
FilOM Tile OUTEll EDGES OF VElllCLE.
I!Y Tile OUTEll LATEllAL SURFACE l 2 nuem/hr IN CAD.
Q<
~~
OF Tile Call oil VElllCLE. 200 mrem /hr I
AT AtJY PetirJT ON Tile EXTEllflAlf 49 CFil 173.393(il 200 mram/hr 9glM e
SUllFACE OF Tile Call Oil ON Tile EXTElltJAL SullFACE O.F
'/j t
9 *'s VElllCLE.1000 mrem /hr Tgb l
Tile PACK AGE.10 maam/hr /'
Wi
{
0 6
()
O-AT 3 f t FROM Tile EXTEnfJAL g.O 9sf AT 3 f t FilOM ANY Da SullFACE OF Tile
~
gO p@
ACCESSillLE EXTEllNAL
/ I p6,yb
-SullFACE OF Tile PACKAGE.
c PACKAGE. 2 mrem /hr gp
~;
IN CA D. ~ ~~" ~ ~ ~ ~
$7 q
- k. kg
(
l
- - - ~
f l\\
/
/g,.*(!
J---
N, l
200 i
m'amthr.
4
, v Q
3
\\
% !s
/A-200
/
vu
'y' t
~/
{
/
g l
6 /
(
, /n &'
\\
l
(
l I
/
/
/
x NOTE: 200 mrem /hr 8
/l
/
N
/
g 7x
- LIMIT ALSO APPLIES 's
.#g,'g sk j
N AT UNDEllSIDE OF g
y VElilCLE.
?
EXCLUSIVE-USE CLOSED TRANSPORT, EXCLUSIVE-USE OPEN TRANSPORT 49 CFH 173.393(i).200 mrem /hr AT ANY POINT ON Tile EXTERNAL, APPENDIX A SUllFACE OF Tile PACK AGE.
t II0 n rem /hr AT 3 f t FilOM ANY.
j IE INFORIMTION NOTICE &} 32 b
'ACCESSIDLE EXTEIINAL l
Q
.SullFACE OF Tile
- c
(
s}
d PACKAGE.
~
l
/
/
,m L
RADIATION :
52
+
0, v3 c
/
a
.' LIMITS m3 O
2cg ~
~
hs g4
~ Y re yk, g
NOTE:
r v
i g,.,
TOTAL Tl IS NOT NOT E:
TO EXCEED 50 PER I
. S IOWAGE OF PACKAGES b
C 49 CFR 173.393(i) AND.'(j) 49 crn ii7.042(.).
c wiTiiiN vEiiiCte muST COMPLY WITil 40 CFil 177.042(bl, NON-EXCLUSIVE-USE OPEN OR CLOSEC n xGaruuc~~-
g:
APPENDIX B IE INF0FPMTION NOTICE N2 WHAT COMPRISES THE PACKAGE?
49 CFR 171.fl DEFINES PACKAGING SUCil TilAT YOU MUST CONSIDER Tile
- .. ASSEMilLY OF ONE OR MORE CONTAINERS AND ANY OTilER COMPONENTS NECESSARY TO AClllEVE COMPLIANCE WITil Tile MINIMUM PACKAGING R E QUIR EMEN TS..':
THEREFORE:
'lNNER ASSEMBLY' OUTErl ENCLOSullE ENTillE OUTER IS A PERSONNEL ASSEMBLY is ENCLOSURE
~
IS" PACKAGE" ~
DARRIER OR SIMULATED
- PACK AG E" IS A SillELD
" CLOSED VElllCLE" wonM
\\_
/(oXo')
'@@N
/@@
'gg%
/
IN Tills SCENARIO, Tile INNER
'lN Tills SCENARIO, Tile PACKAGINGS MAY DE CONSIDERED ENTlflE ASSEMBLY (OUTER SillELD g
i TO DE Tile " PACK AGE", PROVIDED PLUS INNER PACKAGINGSI MUST Tile OUTER ENCLOSURE IS NOT BE CONSIDERED AS Tile " PACKAGE",
i i
NECESSARY TO AClllEVE COMPLIANCE SINCE Tile OUTER SillELD IS NECESSARY TO AcillEVE COMPLIANCE b
WITil Tile RADIATION LEVEL LIMIT I
, OF 173.393(j)(2);l.a.,200 mrem /hr,-
3 WITil 173.393(j)(21. RADIATION rM LEVEL OF llADIATION ON EACll INNER l LEVEL AT SullFACE OF " INNER" C3
" PACKAGE"MAY NOT EXCEED 1 rem /hr AT b
3 f t FROM ITS SURFACE..
"I l PACKAGINGS IS NOT LIMITED.
~~
c=;;,
tr -
IE Information~ Notice No. 80-32
. September 12, 1980 RECENTLY ISSUED IE INFORMATION NOTICES Information Subject Date Issued to Notice No.
Issued 80-31 Maloperation of Gould-8/27/80 All holders of Brown Boveri 480V-Type a power reactor X-6005 and K-DON 6005 OL or CP Circuit Breakers 80-30 Potential for Unaccept-8/27/80 All holders of able Interaction a 8WR power reactor Between the Control OL or CP Rod Drive Scram Function and Non-essential Control Air at Certain BWR Facilities 80-29 Broken Studs on 8/7/80 All holders of Terry Turbine a power reactor Steam Inlet Flange OL or CP Supplement Notification of 7/29/80 All holders of a to 80-06 Significant Events power reactor OL at Operating PowSr and near term OL Reactor Facilities applicants 80-28 Prompt Reporting 6/13/80 All applicants of Required Information for and holders To NRC of a power reactor construction permit 80-27 Degradation of Reactor 6/11/80 All holders of Coolant Pump Studs a pressurized water power reactor OL or CP 80-26 Evaluation of 6/10/80 All holders of a Contractor QA Part 50 License Programs 80-25 Transportation of 5/30/80 Material Licensees Pyrophoric Uranium in Priority / Categories II-A, II-D, III-I and IV-DI; Agreement State Licensees in equivalent categories 1