r,m%

Tsc 4

UNITED STATES 8

  1. k NUCLEAR REGULATORY COMMISSION

';i -

9y' REGION I 04 g

631 PARK AVENUE

-4

,d KING OF PRUSSIA, PENNSYLVANIA 19406 4 +*...

September 12, 1980 Docket-No. 50-170 Defense Nuclear Agency Armed Forces Radiobiology Research Instituta ATTN:

Captain P. Tyler, USN Director Bethesda, Maryland 20014 Gentlemen:

The enclosed IE Information Notice No. 80-32, " Clarification of Certain Requirements for Exclusive-use Shipments of Radioactive Materials," is forwarded to you for in'ormation.

No written response is required.

If you desire additional information regarding this matter, please contact this office.

Sincerely, oyce H. Grier Director

Enclosures:

1.

IE Information Notice No. 80-32 2.

List of Re'cently Issued IE Information Notices CONTACT:

H. W. Crocker (215-337-5217) cc w/encls:

Captain R. Savage, USAF, Physicist 1

1 8009240275 L

SSINS: 6370

- Accession No.:

i 8006190044 f

IN 80-32 i

UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.

20555 August 29, 1980 IE Information Notice No. 80-32:

CLARIFICATION OF CERTAIN REQUIREMENTS FOR EXCLUSIVE-USE SHIPMENTS OF RADIOACTIVE MATERIALS i

===.

Background===

In mid-1979 the NRC initiated an enhanced program for inspection of shipments of radicactive materials, including, in particular, low level wastes.

In conjunc-tion with this effort, civil penalties have been assessed for violation of associated regulatory requirements.

IE Bulletins 79-19 and 79-20, " Packaging of Low Level Radioactive Waste for Transport and Burial," issued August 8, 1979 and IE Information Notice 79-21, " Transportation and Commercial Burial of Radioactive Material," issued September 7,1979, provide background in this regard.

During the past year, this augmented inspection / enforcement program has prompted a number of questions on the proper application of certain regulatory requirements.

These questions involve mainly the problems and deficiencies associated with exclusive use highway shipments of low-level radioactive wastes.

The purpose of this Notice is to discuss the questions and clarify the applicability of certain requirements.

Acolication of 49 CFR 173.393(i) and (f)

Numerous questions involve the application of the limits of radiation levels of exclusive use shipments as prescribed in 49 CFR 173.393(j).

As stated therein, the regulation reads (j)

Packages for which the radiation dose rate exceeds the limits specified in paragraph (i) of this section, but does not exceed at any time during transportation any of the limits specified in para-graphs (j)(1) through (4) of-this section may be transported in a transport vehicle which has been consigned as exclusive use (except aircraft).

Specific instructions for maintenance of the exclusive use (sole use) shipment controls must be provided by the shipper to the carrier.

Such instructions must be included with the shipping 1

paper information:

(1) 1,000 millirem per hour at 3 feet from the external surface of the package (close (2) 200 millirem per h DUPLICATE DOCUMENT the car or vehicle Entire document previously entered into system under:

OC WM ANO No. of Pages:

49 CFil 173.303111 10 mem/hr

.19 CFH 173.303(1)-10 mrzm/hr 2 marm/hr AT ANY POINT 2 m (G 11) e2 mesin/lu AT ANY POINT 2 m (G lt)

FilOM Tile VEllTICAL PLANES PilOJECTED FilOM Tile VEllTICAL PLAFJE PflOJECTED FilOM Tile OUTEfl EDGES OF VElllCLE._

IlY Tile OUTEll LATEN AL SUllFACE l2 miem/hr IN CAD.

.~

Q'

. OF Tile Call oil VElllCLE. 200 mrem /hr I

s AT ANY PolNT ON Tile EXTEnfJAlf~

49 CFn 173.393(i) 200 mrem /hr M

N

(

/ ((

SullFACE OF Tile Call Oil t

\\g @ p go #'#

d l.

ON Tile EXTEIINAL SullFACE OF Tile PACK AGE.10 mrem /hr.,'

b VElllCLE.1000 mrem /hr g

i f ()

[

/ [

p.

d @M AT 3 It FilOM Tile EXTERNAL 40 AT 3 It FilOM ANY N

,O p

- SullFACE OF Tile

~~

gA p

ACCESSillLE EXTEllNAL g#p PACKAGE. 2 mrem /hr g

g g

-SullFACE OF Tile PACKAGE.

1

~ ~ ~ ~ ~ 3 q

I'C +gd h

1x %,

(

1 IN cho.

/

l

\\

D. 00/*

2 s

g+lS$'

sh,,,,A 4Q

'y' s

s w

v

/g, c(

\\

\\ gy\\

((

\\

/

~

t

.y

,4*

I

/

/

/

NOTE: 200 mrom/hr 8

/)

/

\\

/

.Y 7

0\\[4h 4,

LIMIT ALSO APPLIES 'i g

5

's AT UNDEllSIDE OF k

y VElllCLE.

I EX.CLUSIVE-USE CLOSED TRANSPORT, EXCLUS VE-USE OPEN. TRANSPORT 49 CFil 173.393(il-200 mrem /hr AT ANY POINT ON Tile EXTEHNAL, APPENDIX A SUIIFACE OF Tile PACKAGE.

i

,fCC SSI L

'"^N E

ER lA IE INFORIMTION NOTICE 8)-32

.SunFACE OF Tile PACKAGE.

p'g

/(

+

H i

RADIATION :

,N/ C "

g

! LIMITS n

C 0

6 flOTE:

4r TOTAL Tl 15 NOT NOTE:

C~'

TO EXCEED 50 PER !

. STOWAGE OF PACKAGES 49 CFR 173.393(i) AND.'(j) j?==

]5D 49 CI'It 177.042(a),

f WITillN VElllCLE MUST COMPLY WITil 49 CFil 177.042(bl, NON-EXCLUSIVE-USE OPEN OR CLOSED ern Ja n n rvr

  1. l APPENDIX B IE INF0feMTION NOTICE 80 32 WHAT COMPRISES THE PACKAGE?

49 CFR 171.fl DEFINES PACKAGING SUCll TilAT YOU MUST CONSIDER Tile

.. ASSEMilLY OF ONE On MORE CONTAINERS AND ANY OTilER COMPONENTS NECESSARY TO ACillEVE COMPLIANCE WITil Tile MINIMUM PACKAGING R EQUIR EM ENTS..':

THEREFORE:

'INNEll ASSEMBLY' OUTER ENCLOSURE ENTIRE OUTER IS *' PACKAGE" '~'

IS A PERSONNEL ASSEMBLY l3 ENCLOSURE DARRIER On SIMULATED

PAC K AG E" IS A SiliELD

" CLOSED VT.lilCLE" 4===o nM

\\

IN Tills SCENARIO, Tile INNER

'IN Tills SCENARIO, Tile Q,

PACKAGINGS MAY DE CONSIDERED ENTIRE ASSEMBLY lOUTER SillELD p

TO DE TIIE " PACKAGE", PROVIDED PLUS INNER PACKAGINGS) MUST 6_

Tile OUTER ENCL.OSUflE IS NOT NECESSARY TO AcillEVE COMPLIANCE

. DE CONSIDEllED AS Tile " PACKAGE",

e SINCE Tile OUTER SillELD IS WITil Tile RADIATION LEVEL LIMIT I

NECESSARY TO ACillEVE COMPLIANCE

. OF 173.393(j)(2);i.e.,200 mrom/hr, IWITil 173.393(1)(21. RAOlATION EEL 9 i

LEVEL OF R ADIATION ON EACllINNEll l LEVEL ATSUflFACE OF " INNER" 5

3 f t FROM ITS SURFACE..

b3 cd

" PACKAGE"MAY NOT EXCEED 1 rem /hr AT.I l PACKAOINGS IS NOT LIMITED.

c-b

IE Information Notice No. 80-32 September 12, 1980 RECENTLY ISSUED IE INFORMATION NOTICES Information Subject Date Issued to Notice No.

Issued 80-31 Maloperation of Gould-8/27/80 All holders of Brown Boveri 480V-Type a power reactor K-6005 and K-DON 600S OL or CP Circuit Breakers 80-30 Potential for Unaccept-8/27/80 All holders of able Interaction a BWR power reactor Between the Control OL or CP Rod Drive Scram Function and Non-essential Control Air at Certain BWR Facilities 80-29 Broken Studs on 8/7/80 All holders of Terry Turbine a power reactor Steam Inlet Flange OL or CP Supplement Notification of 7/29/80 All holders of a to 80-06 Significant Events power reactor OL at Operating Power and near term OL Reactor Facilities applicants 80-28 Prompt Reporting 6/13/80 All applicants of Required Information for and holders To NRC of a power reactor construction permit 80-27 Degradation of Reactor 6/11/80 All holders of Coolant Pump Studs a pressurized water power reactor OL or CP 80-26 Evaluation of 6/10/80 All holders of a Contractor QA Part 50 License 4

Programs 80-25 Transportation of 5/30/80 Material Licensees Pyrophoric Uranium in Priority / Categories II-A, II-D, III-I and IV-DI; Agreement State Licensees in equivalent categories

.