The enclosed IE Information Notice No. 80-32, " Clarification of Certain Requirements for Exclusive-use Shipments of Radioactive Materials," is forwarded to you for information.
No written reLponse is required.
If you desire additional information regarding this matter, please contact this office.
Sincerely, oyce H. Grier Director
Enclosures:
1.
IE Information Notice No. 80-32 2.
List of Recently Issued IE Information Noticts CONTACT:
H. W. Crocker (215-337-5217) cc w/encls:
Dr. R. Belcher, Reactor Director Dr. F. Munno, Chairman, Nuclear Engineering Group Dr. J. S. Toll, P. resident j
l 800924 0 2 4T i
SSINS: 6370 Accession No.:
7 8006190044 IN 80-32 l
UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, O.C.
20555 August 29, 1980 IE Information Notice No. 80-32:
CLARIFICATION OF CERTAIN REQUIREMENTS FOR EXCLUSIVE-USE SHIPMENTS OF RADI0 ACTIVE MATERIALS
\\
===.
Background===
In mid-1979 the NRC initiated an enhanced program for inspection of shipments of radioactive materials, including, in particular, low level wastes.
In conjunc-tion with this effort, civil penalties have been assessed for violation of associated regulatory requirements.
IE Bulletins 79-19 and 79-20, " Packaging of Low Level Radioactive Waste for Transport and Burial," issued August 8, 1979 and IE Information Notice 79-21, " Transportation and Commercial Burial of Radioactive Material," issued September 7,1979, provide background in this regard.
During the past year, this augmented inspection / enforcement program has prompted a number of questions on the proper application of certain regulatory requirements.
These questions involve mainly the problems and deficiencies associated with exclusive use highway shipments of low-level radioactive wustes.
The purpose of this Notice is to discuss the questions and clarify the applicability of certain requirements.
Acolication of 49 CFR 173.393(i) and (j)
Numerous questions involve the application of the limits of radiation levels of exclusive use shipments as prescribed in 49 CFR 173.393(j).
As stated therein, the regulation reads (f)
Packages for which the radiation dose rate exceeds the limits specified in paragraph (i) of this section, but does not exceed at any time during transportation any of the limits specified in para-graphs (j)(1) through (4) of this section may be transported in a transport vehicle which has been consigned as exclusive use (except aircraft).
Specific instructions for maintenance of the exclusive use (sole use) shipment controls must be provided by the shipper to the carrier.
Such instructions must be included with the shipping paper information:
(1) 1,000 millirem per hour at 3 feet from the external surface of the package (close (2) 200 millirem per h DUPLICATE DOCUMENT the car or vehicle Entire docurnent previously entered into system under:
ANO DUD No. of Pages:
3
4'l CFil 173.303(11 10 mr:m/hr
.19 CFil 173.303ll).10 mrEn/hr 2 mgm/hr AT ANY POINT 2 m (G f t)
- 2 mM AT ANY l'OINT 2 m (G lt)
FilOM Tile VEllTICAL PLANES PilOJECTED'
~
FilOM Tile VEllTICAL PLANE Pl10JECTED FilOM Tile OUTEll EDGES OF VElllCh' a
CY Tile OUTER LATEllAL SUIIFACE l 2 miem/hr IN Call.
OF Tile Call OR VElllCLE. 200 mrem /hr I
s AT ANY PrtitJT ON Tile EXTEllNALF 49 CFil 173.393(il 200 miem/hr A
d D
j i
' SullFACE OF Tile Call Oil ~ '
pigo
- g@
[
[
Tile PACKAGE.10 mrem /hr f' ' '
l ON Tile EXTERNAL SUHFACE OF ga VElllCLE 1000 miem/hr g-3g.
- p@
c,gM eN
,f[
'(
- UI F CE OF Tile 90 CESS I LE EX E11NAL f-
- PACKAGE. 2 mrem /hr q @,po
~
- - ' ~ ~ ~ ~ ~ ~ ~
SullFACE OF Tile PACKAGE.
A I N CAD. ~ ~~~ ~ ~ 3
(
Im
(
1 4
g As, *k l
't y
A y
i v
~
l, A
- d* r
\\
\\
N
~
h*',
\\
\\ gV '
c 3/
c' l
,\\
/f
/
NOTE: 200 mrem /hr 8 I
g
- ,,'g g
LIMIT ALSO APPLIES 4
s AT UNDEllSIDE OF Nbk y
VElllCLE.
?
EXCLUSIVE-USE' CLOSED TRANSPORT, EXCLUSIVE-USE OPEN TRANSPORT 49 Cril 173.393(i)-200 mrem /hr AT ANY POINT ON Tile EXTEIINAL.
APPENDIX A i
- ,SUllFACE OF Tile PACKAGE.
Q i
'lCCESS$'t^'U'EI"I$f^"*,.
\\ /' )
IE INF0fUMT10N t0TICE $} 32 (555D E
l I.SUHFACE OF TIIE
~~
s*
'/ $
t PACKAGE.
t 0
m
- 4 H
RADIATION :
s 1
I v,
c
/
. LIMITS GR v
00,,,,,
v 6
g NOTE:
4r M
TOTAL Tl is NOT NOT E:
[f.
TO EXCEED 50 PEIl !
. STOWAGE OF PACKAGES 49 CFR 173.393(i) AND.'(j) 49 t'r fl 177.042(a),
f WITillN VElllCLE MUST COMPLY WITil 49 CFl! 1,77.842(bl, NON-EXCLUSIVE-llSE OPEN OR CLOSED
1 APPENDIX B
~
IE INFOR mTION NOTICE @ 32 WHAT COMPRISES THE PACKAGE?
49 CFR 171.fl DEFINES PACK AGING SUCll TilAT YOU MUST CONSIDER Tile
- .. ASSEMill.Y OF ONE On MORE CONTAINERS AND ANY OTilER COMPONENTS NECESSARY TO AClllEVE COMPLIANCE WITli Tile MINIMUM PACKAGING REQUlilEMENTS..::
THEREFORE:
' INNER ASSEMDI.Y' OUTER ENCLOSUllE ENTillE OUTER IS A PERSONNEL ASSEMBLY is ENCLOSURE IS ** PACKAGE" '"
(IARRIER OR SIMULATED
- PACK AG E" IS A SillELD
" CLOSED VElllCLE" 4---on e
\\
,T
'gg%
E-
@@N
/@@ E{
' IN Tills SCENARIO, Tile INNER
',1N Tills SCENARIO, Tile -
PACKAGINGS MAY BE CONSIDERED ENTIRE ASSEMBLY (OUTER SillELD C%$
TO BE Tile " PACK AGE", PROVIDED PLUS INNER PACKAGINGS) MUST M
Tile OUTER ENCLOSURE 2S NOT NECESSARY TO AcillEVE COMPLIANCE
. DE CONSIDERED AS Tile PACKAGE",
e SINCE Tile OUTER SillELD is
[d WITil Tile RADIATION LEVEL LIMIT I NECESSARY TO ACillEVE COMPLIANCE
, OF 173.393(j)(2);i.e.,200 mrem /hr, IWITil 173.393()){2). RADIATION i
LEVEL OF RADIATION ON EACilINNER
[ LEVEL AT SURFACE OF "lNNER"
" PACKAGE"MAY NOT EXCEED 1 rem /hr AT)
,3 It FROM ITS SURFACE..
l PACKAGINGS IS NOT LIMITED.
~~
f
r:
IE Information Notice No. 80-32 September 12, 1980 RECENTLY ISSUED IE INFORMATION NOT 1 15 Information Subject Date Issued to Notice No.
Issued 80-31 Maloperation of Gould-8/27/80 All holders of Brown Boveri 480V-Type a power reactor K-6005 and K-DON 600S OL or CP Circuit Breakers 80-30 Potential for Unaccept-8/27/80 All holders of able Interaction a BWR power reactor Between the Control OL or CP Rod Drive Scram Function and Non-essential Control Air at Certain BWR Facilities 80-29 Broken Studs on 8/7/80 All holders of Terry Turbine a power reactor Steam Inlet Flange OL or CP Supplement Notification of 7/29/80 All holders of a to 80-06 Significant Events power reactor OL at Operating Power and near term OL Reactor Facilities applicants 80-28 Prompt Reporting 6/13/80 All applicants of Required Information for and holders To NRC of a power reactor construction permit 80-27 Degradation of Reactor 6/11/80 All holders of Coolant Pump Studs a pressurized water power reactor OL or CP J
80-26 Evaluation of 6/10/80 All holders of a Contractor QA Part 50 License Programs 80-25 Transportation rf 5/30/80 Material Licensees Pyrophoric Uranium in Priority / Categories II-A, II-D, III-I and IV-DI; Agreement State Licensees in equivalent categories l