631 PARK AVENUE KING oF PRUSSIA, PENNSYLVANIA 19 06 September 12, 1980 Docket No. 50-05 The Pennsylvania State University ATTN:
Dr. Richard G. Cunningham Vice President for Research and Graduate Studies University Park, Pennsylvania 16802 Gentlemen:
The enclosed IE Information Notice No. 80-32, " Clarification of Certain Requirements for Exclusive-use Shipments of Radioactive Materials," is forwarded to you for information.
No written response is required.
If you desire additional information regarding this matter, please contact this office.
Sincerely, oyce H. Grier Director
Enclosures:
1.
IE Information Notice No. 80-32 2.
List of Recently Issued IE Information Notices CONTACT:
H. W. Crocker (215-337-5217) cc w/encls:
4 R. W. Granlund, University Health Physicist
'80092401M
SSINS: 6370 Accession No.:
i 8006190044 IN 80-32 f
UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.
20555 August 29, 1980 IE Information Notice No. 80-32:
CLARIFICATION OF CERTAIN REQUIREMENTS FOR EXCLUSIVE-USE SHIPMENTS OF RADI0 ACTIVE MATERIALS
\\
Background
In mid-1979 the NRC initiated an enhanced program for inspection of shipments of radioactive materials, including, in particular, low level wastes.
In conjunc-tion with this effort, civil penalties have been assessed for violation of associated regulatory requiraments.
IE Bulletins 79-19 and 79-20, " Packaging of Low Level Radioactive Waste for Transport and Burial," issued August 8, 1979 and IE Information Notice 79-21, " Transportation and Commercial Burial of Radioactive Material," issued September 7,1979, provide background in this regard.
During the past year, this augmented inspection / enforcement program has prompted a number of questions on the proper application of certain regulatory requirements.
These questions involve mainly the problems and deficiencies associated with exclusive use highway shipments of low-level radioactive wastes.
The purpose of this Notice is to discuss the questions and clarify the applicability of certain requirements.
Acolication of 49 CFR 173.393(i) and (j)
Numerous questions involve the application of the limits of radiation levels of exclusive use shipments as prescribed in 49 CFR 173.393(j).
As stated therein, the regulation reads (j)
Packages for which the radiation dose rate exceeds the limits specified in paragraph (i) of this section, but does not exceed at any time during transportation any of the limits specified in para-graphs (j)(1) through (4) of this section may be transported in a transport vehicle which has been consigned as exclusive use (except aircraft).
Specific instructions for maintenance of the exclusive use (sole use) shipment controls must be provided by the shipper to the carrier.
Such instructions must be included with the shipping paper information:
(1) 1,000 millirem per hour at 3 feet from the external surface of the package (close (2) 200 millirem per h DUPLICATE DOCUMENT the car or vehicle Entire document previously entered into system under:
OUD ANO No. of Pages:
3
411 CFil 173.3D3(11-10 me:m/hr 2 imampir AT ANY POffJT 2 m (G lt)
. 2 malen/l=
C CFil 173.393(1) 10 mrzm/h' AT ANY l'OlfJT 2 m (G lt)
' ' " ~
FHOM Tile VERTICAL PLANES PflOJECTED FilOM Tile VEliTICAL PLANE PROJECTED.
CY Tile OUTER LATEllAL SURFACE l FitOM Tile OUTER EDGES OF VElllCLE.J
.' ~
C:F Tile Call On VElllCLE. 200 mrem /hr l 2 mrem /hr ifJ CAD.
49 CFR 173.393(1).200 miem/hr AT ANY P8tifJT ON Tile EXTEllNALF" eD,,
\\
(
SUHFACE OF Tile CAf1 Oll* ~ '
gi ON Tile EXTEnfJAL SullFACE OF
%g@9 g *'g lg Tile PACKAGE.10 inrem/hr, ~~
{
VElllCLE.1000 mrem /hr g
}
0 AT3 i FROM Tile EXTERNAL SullFACE OF Tile
- ' ' gO 4@
b
(/
AT 3 It FilOM ANY
/
t[
/
f ACCESSillLE EXTEllNAL
/ b gM,@@
c p
PACKAGE. 2 mrem /hr e
SullFACE OF Tile PACKAGE.
N IN CAD. ~~~"*~ ~ i q
q O,
(
~
~ ~ ' ~ ~ ~ ~ ~
N-(
g r
, ts kg
/hr.
O **
1 y
mra g
g 204
/
.y (t s
/
'eg V
\\
{
\\ v" 4**
\\
\\ sy\\
(c,
,/.@
/
l
/
e,/
(c 4
t i
'(
/f-N
/
NOTE: 200 sniem/hr I N
g
- LIMIT ALSO APPLIES 's O
}
','g'N, AT Uf3DEHSIDE OF g
?
y VElllCLti.
EXCLUSIVE-USE CLOSED TRANSPORT, EXCLUSIV.E-USE OPEN TRANSPORT 49 CFil 173.393(il-200 mrem /hr
- AT ANY POlfJT ON Tile EXTEIINAL.
APPENDIX A
,SUHFACE OF Tile PACKAGE.
g i
110 o rrm/lir AT3 ft FIlOM ANY' IE INFORfMTION NOTICE g}-32 Cc-5-)
'ACCESSlHLE EXTEllNAL
.SUnFACE OF Tile l
Oi w,
t PACKAGE.
~
^
m'
/
- M) l
+
0, RADIATION :
c=r I
v.
c g
/
.' LIMITS ro C:
EE'-
o FJOTE:
4r FM TOTAL Tl is NOT FJOTE:
g TO FXCEED 50 PER !
. SlOWAGE OF PACKAGES 49 CFR 173.393(i) AND.'(j) 49 rFil 177.042(a),
f WITillfJ VElllCLE MUST b
COMPLY WITil 40 Crfl 177.042(bl, NON-EXCLUSIVE-USE OPEN OR CLOSED viuGae annam-
I APPENDIX B IE INF0lWMTION NOTICE M 32 WHAT COMPRISES TtlE PACKAGE?
49 CFR 171.fl DEFINES PACKAGING SUCll TilAT.du MUST CONSIDER TiiE
" ASSEMilLY OF ONE OR molle CONTAINERS AND ANY OTHER COMPONENTS NECESSAi1Y TO ACillEVE COMPLIANCE WITil Tile MINIMUM PACKAGING R EQUlH EMENTS..*:
THEREFORE:
' INNER ASSEMBLY' OUTER ENCLOSURE ENTIRE OUTER is A PEllSONNEL ASSEMBLY is ENCLOSURE IS " PACK AGE" ~
RARRIER OR SIMULATED
" PACKAGE" IS A SillELD
" CLOSED VElllCLE" w on M
// N
@@\\
/N
^ IN Tills SCENAnlO, Tile INNER
'IN Tills SCENARIO, Tile 7@
PACKAGINGS MAY BE CONSIDERED ENTIRE ASSEMBLY lOUTER SHIELD C
TO DE Tile " PACKAGE", PROVIDED PLUS INNER PACKAGINGS)MUST p;
Tile OUTER ENCLOSURE IS NOT BE CONSIDERED AS THE " PACKAGE",
e j
NECESSARY TO AcillEVE COMPLIANCE SINCE Tile OUTER SHIELD IS
^
WITil Tile RADIATION LEVEL LIMIT I
NECESSARY TO ACHIEVE COMPLIANCE
, OF 173.393(il(2);i.e.,200 mrem / lire I WITH 173.393(j)l2). RADIATION LEVEL OF RADIATION ON EACllINNER l LEVEL AT SURFACE OF "lNNER" f_43)
" PACKAGE"MAY NOT EXCEED 1 rem /lw AT) l PACKAGINGS IS NOT LIMITED.
~~
6f s
+
3 ft FilOM ITS SURFACE..
W EED t:
IE Information Notice No. 80-32 September 12, 1980 RECENTLY ISSUED IE INFORMATION NOTICES Information Subject Date Issued to I
Notice No.
Issued 80-31 Maloperation of Gould-8/27/80 All holders of Brown Boveri 480V-Type a power reactor K-600S and K-DON 6005 OL or CP Circuit Breakers 80-30 Fotential for Unaccept-8/27/80 All holders of able Interaction a BWR power reactor Eetween the Control OL or CP Rod Drive Scram Function and Non-essential Control Air at Certain BWR Facilities 80-29 Broken Studs on 8/7/80 All holders of Terry Turbine a power reactor Steam Inlet Flange OL or CP Supplement Notification of 7/29/80 All holders of a to 80-06 Significant Events power reactor OL at Operating Power and near term OL Reactor Facilities applicants 80-28 Prompt Reporting 6/13/80 All applicants of Required Information for and holders To NRC of a power reactor construction permit 80-27 Degradation of Reactor 6/11/80 All holders of Coolant Pump Studs a pressurized water power reactor OL or CP 80-26 Evaluation of 6/10/80 All holders of a Contractor QA Part 50 License Programs 80-25 Transportation of S/30/80 Material Licensees Pyrophoric Uranium in Priority / Categories II-A, II-D, III-I and IV-DI; Agreement State Licensees in equivalent categories