KING OF PRUSSIA, PENNSYLVANIA 19406 September 12, 1980 Docket No. 50-77 l
Catholic University ATTN:
Dr. Y. C. Whang, Chairman Mechanical Engineering Department 620 Michigan Avenue, N. E.
Washington, D. C.
20064 Gentlemen:
The enclosed IE Information Notice No. 80-32, " Clarification of Certain Requirements for Exclusive-use Shipments of Radioactive Materials," is forwarded to you for information.
No written response is required.
If you desire additional information regarding this matter, please contact this office.
Sincerely, oyce H. Grier Director
Enclosures:
1.
IE Information Notice No. 80-32 2.
List of Recently Issued IE Information Notices CONTACT:
H. W. Crocker (215-337-5217) cc w/encls:
Dr. E. D. Jordan, Director of Information Systems and Planning W. Keene, Radiation Safety Official i
&0092401\\$
SSINS: 6370
- Accession No.:
~-/
8006190044 IN 80-32 l
UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON,.D.C.
20555 August 29, 1980 IE Information Notice No. 80-32:
CLARIFICATION OF CERTAIN REQUIREMENTS FOR EXCLUSIVE-USE SHIPMENTS OF RADIOACTIVE MATERIALS
\\
===.
Background===
In mid-1979 the NRC initiated an enhanced program for inspection of shipments of radioactive materials, including, in particular, low level wastes.
In conjunc-tion with this effort, civil penalties have been assessed for violation of associated regulatory requirements.
IE Bulletins 79-19 and 79-20, " Packaging of Low Level Radioactive Waste for Transport and Burial," issued August 8, 1979 and IE Information Notice 79-21, " Transportation and Commercial Burial of Radioactive Material," issued September 7,1979, provide background in this regard.
During the past year, this augmented inspection / enforcement program has prompted a number of questions on the proper application of certain regulatory requirements.
These questions involvc mainly the problems and deficiencies associated with exclusive use highway shipments of low-level radioactive wastes.
The purpose of this Notice is to discuss the questions and clarify the applicability of certain requirements.
Acolication of 49 CFR 173.393(i) and (j)
Numerous questions involve the application of the limits of radiation levels of exclusive use shipments as prescribed in 49 CFR 173.393(j).
As stated i
therein, the regulation reads (j)
Packages for which the radiation dose rate exceeds the limits specified in paragraph (i) of this section, but does not exceed at any time during transportation any of the limits specified in para-graphs (j)(1) through (4) of this section may be transported in a trancport vehicle which has been consigned as exclusive use (except aircraft).
Specific instructions for maintenance of the exclusive use (sole use) shipment controls must be provided by the shipper to the carrier.
Such instructions must be included with the shipping paper information:
(1) 1,000 millirem per hour at 3 feet from the external surface of the package (close (2) 200 millirem per h DUPLICATE DOCUMENT the car or vehicle i
Entire docurrent previously l
entered into system under:
$DD UD ANO l
No. of pages: __J l
I
49' Fil 173.303(j)-10 mrsm/hr 19 CFH 173.393fl).10 mrem /hr 2 imem/hr AT ANY POINT 2 m (G fI)
. 2 nuaim/lw AT ANY POINT 2 m (G It)
Fil0M Tile VERTICAL PLANES PilOJECTED:
b.
FilOM Tile VEllTICAL PLANE PHOJECTED.
FilOM Tile OUTEll EDGES OF VElllCLE.
IlY Tile OUTEli LATEllAL SUHFA CE l 2 mrem /hr IN CAD.
.~
OF Tile Call On VElllCl_E. 7')0, rem /hr l
s AT ANY ImlNT ON Tile EXT '.JAlf" 49 CFil 173.393(il 200 mrem /hr M
/ 'L ON Tile EXTEntJAL SUflFACE 0,F
/
e SullFACE OF Tile Call Oil VElllCLE.1000 mrem /hr ob go *'#
99t
/
I
[
Tile PACKAGE.10 mram/hr /'
-l 9
c) 9 AT 3 f FilOM TIIE EXTERNAL-sb AT 3 It FROM ANY ACCESS!!!LE EXTEllNAL
/ b SUIIFACE OF Tile F
p PACKAGE. 2 mrem /hr
' " ' - ~ ' ' ' ~ j qp,po SullFACE OF Tile PACKAGE.
A
@f,
- k. 'f
(
I IN CAD.
f D
/
m'ra /lir.
(
i V
y ps A v.
e, y
y i
y c'
h j
,/-
l V
c
/f N
/
NOTE: 200 mrern/hr i I
- LIMIT ALSO APPLIES
}
s AT UNDERSIDE OF 4
y VElllCLE.
EXCLUSIVE-USE CI_OSED TRANSPORT, EXCLUSIVE-USE OPEN TRANSPORT 49 CFR 173.393(1) 200 mremihr AT ANY POINT ON Tile EX1FDNAL.
APPENDIX A
,SUllFACE OF Tile PACKAGE.
N 110 o rrm/hr AT 3 f t FROM AtJY N
4 W
)'
IE INFORIMTION NOTICE g}-32 L
'ACCESSIDLE EXTEllNAL g
l
.SUHFACE OF Tile g
PACKAGE.
s
/ c u
/xY
- v 6
M RADIATION :
s; a i
c
.' LIMITS A
V 24~
Mr
~ Y NOTE:
'4r v
~
TOTAL TI IS NOT FJOTE:
TO EXCEED 50 PEll !
. STOWAGE OF PACKAGES 49 CFH 177.042(a).
\\f 49 CI:R 173.393(i) AND.'(j)
WITillN VElllCLE MUST COMPLY WITil 49 Cril 177.042(b),
NON-EXCLUSIVE-USE OPEN OR CLOSED vcnaas on rmw - - - - - - - - - - - - -
' y..
APPEf0lX B IE INFORf% TION FOTICE 80 32 WHAT COMPRISES THE PACKAGE?
49 CFR 171.11 DEFINES PACK AGING SUCll TilAT YOU MUST CONSIDER Tile
.:.. ASSEMilLY OF ONE On MORE CONTAINERS AND ANY OTilER COMPONENTS NECESSARY TO AClllEVE COMPLIANCE WITil Tile MINIMUM PACKAGING R EOUIREMENTS..::
THEREFORE:
'INNEIl ASSEMBLY' OUTEll ENCLOSURE ENTIRE OUTER IS A PERSONNEL ASSEMBLY IS ENCLOSURE IS " PACK AGE"
RARR! Ell OR SIMULATED
" PACK AGE" iS A SillELD
" CLOSED VElllCLE" hon 4 g%
//g' g\\
fg' a
~ IN Tills !!CENARIO, Tile INNER
',lN Tills SCENARIO, Tile PACKAGINGS MAY BE CONSIDEllED ENTIRE ASSEMDLY (OUTER SillELD Q
TO tlE Tile " PACK AGE", PROVIDED PLUS INNER PACKAGINGS) MUST p
Tile OUTER ENCLOSURE IS NOT NECESSAIlY TO AC!llEVE COMPLIANCE
. DE CONSIDERED AS Tile ** PACKAGE",
i SINCE TL E OUTER SillELD IS WITil Tile RADIATION LEVEL LIMIT
'NECE.iSANY TO AcillEVE COMPLIANCE p
, OF 173.333(i)(2);i.e. 200 mrom/hr, I
WITil 173.3., d)(2). HADIATION LEVEL OF RADIATION ON EACll INNER l LEVEL AT SUHFACE OF "lNNER" g
" PACKAGE"MAY NOT EXCEED 1 rem /hr AT.I l PACKAOlNGS IS NOT LIMITED.
,3 f t FROtA ITS SURFACE..
(L IE Information Notice No. 80-32
' September 12, 1980 RECENTLY ISSUED IE ?NFORMATION NOTICES Information Subject Date Issued to Notice No.
Issued 80-31 Maloperation of.Gould-8/27/80 All holders of Brown Boveri 480V-Type a power reactor K-600S and K-DON 600S OL or CP Circuit Breakers 80-30 Potential for Unaccept-8/27/80 All holders of able Interactic..
a BWR power reactor Between-the Control OL or CP Rod Drive Scram Function and Non-essential Control Air at Certain BWR Facilities j
80-29 Broken Studs on 8/7/80 All holders of Terry Turbine a power reactor Steam Inlet Flange OL or CP 1
Supplement Notification of 7/29/80 All holders of a to 80-06 Significant Events power reactor OL at Operating Power and near term OL Reacto Facilities applicants 80-28 Prompt Reporting 6/13/80 All applicants of. Required Information for and holders To NRC of a power reactor construction permit 80-27 Degradation of Reactor 6/11/80 All holders of Coolant Pump Studs a pressurized water power reactor OL or CP 80-26 Evaluation of 6/10/80 All holders of a Contractor QA Part 50 License Programs 80-25 Transportation of 5/30/80 Material Licensees Pyrophoric Uranium in Priority / Categories II-A, II-D, III-I and IV-DI; Agreement State L.censees in equivalent categories