ML19338D922

From kanterella
Jump to navigation Jump to search
Describes Util Alternative for Reactor Recirculation Pump Lubrication Sys Protection,In Response to NRC . Proposed Method Incorporates Oil Collection Sys Designed to Withstand Category I Seismic Event
ML19338D922
Person / Time
Site: Vermont Yankee File:NorthStar Vermont Yankee icon.png
Issue date: 09/19/1980
From: Conway W
VERMONT YANKEE NUCLEAR POWER CORP.
To: Ippolito T
Office of Nuclear Reactor Regulation
References
WVY-80-130, NUDOCS 8009240207
Download: ML19338D922 (2)


Text

_.

-G 9 YlclO!ONT Y ANisicic NucLicAu POwicR CORI*OR ATION

' (_.

~

SEVENTY SEVEN GROVE STREET B.3.2.1 WVY 80-130 RUTI.AND. VI:RS1ONT 05701 REPLY TO:

ENGINEERING OFFICE TURNPIKE RO Ao WESTDORO. M ASS ACHUSETTS 01581 TELEPHONE 6 t ? 166 909 0 September 19, 1980_

United States Nuclear Regulatory Commission Washington, D.C.

20555 '

Attention:

Office of Nuclear Reactor Regulation

~

Thomas A.

Ippolito, Chief Operating Reactors Branch #2 Division of Licensing

References:

(a) License No. DPR-28 (Docket No. 50-271)

(b) USNRC Letter to R. L. Smith from T. A. Ippolito, dated February 20. 1980,

Subject:

Supplemental Safety Evaluation (c) VYNPC Letter (VVY 80-43) to T. A. Ippolito from W. F. Conway, dated March 14, 1980,

Subject:

Supplemental Safety Evaluation

Dear Sir:

I

SUBJECT:

Primary Containment Analysis Reference (c) above indicated we would provide you with a com-l-

mitment to one of the acceptable alternatives for protection of the l

_ Reactor Recirculation Pump Lubrication System.

The alternative we have chosen incorporates an oil collection system which is designed to withstand a Category I seismic event and continue to be abic to collect and drain leakage that may occ,ur during that event. A de-scription of the. system follows:

The General Electric motors used on the Vermont Yankee reactor recirculation pumps are of a bath type (unpressurized) design.

The only piping that is external to the motor is a fill and drain connection for each bearing.. The only potential for oil leakage would be as a' result of an oil cooler rupture which would leak water into the oil and overflow the oil bath reser-voir down.the armature onto the pump. We will provide an over-flow collection system at cach oil bath reservoir, sized to i

handle the flow from a ruptured oil cooler. We will collect

[

the overflow and deposit it in a closed, vented container.

The collection system _will be designed to withstand Category I seismic events.

l t

8009240 V 7 -

a VERMONT YANKEE NUCLEAR POWER CORPORATION j

United States Nuc1 car Regulatory Commission September 19, 1980 Page 2 We trust that this responds to the staff concerns expressed in Reference (b) above and will proceed with the design immediately.

Very truly yours, VERMONT YANKEE NUCLEAR POWER CORPORATh)N William F. Co way Vice President and Manager of Operations Dcc/j h i