.9 -
Form NRC 618 U.S. NUCLEAR REGULATORY COMMISSloN CERTIFICATE OF COMPLIANCE 10 CFR 71 For Radioactive Materials Packages a
1.la) C ti e Number 1.lb) Revis n No.
1.l P
1 i ic ion No.
1.(d) P es No. 1.(e) Tot No. Pages
- 2. PREAM8LE 2.la)
This certificate is issued to satisfy Sections 173.l93a 173.394.173.395, and 173.396 of the Oeoartment of Transportation Hazarcous Materials Regulations 149 CFR 170189 and 14 CFR 103) and Sections 146-19-10a and 146-19-100 of the Department of Transportation oangerous Cargoes Reguletons (46 CFR 146-149). as amended.
2.(b)
The packagira and contents described in item 5 below, meets the safety standards set forth in Suboart C of Title 10. Code of Federal Regulations. Part 71 ** Packaging of Radioactive Materials for Transport and Transportation of Radioacts. e Matenal Under Certain Conditions."
2.(c)
This certificate does not relieve the consignor from compliance with any roouirement of the regulations of the U.S. Department of Transportation or other aconicable regulatory. agencies, induding the government of any country through or into which the package will be transoorted.
- 3. This certificate is issued on the basis of a safety analysis report of the package design er apolication-3.(a)
Prepared by (Name and address):
3.(b)
Title and identification of report or aoslication:
General Electric Company General Electric Company application dated P. O. Box 460 April 22, 1980, as supplement 4 l
Pleasanton, CA 94566 3.(c)
Oocicet No 4 CONDITIONS This certificate is cceditional upon the fulfilling of the roouirements of Subpart O of 10 CFR 71, as apolicable, and the conditions specified in item 5 below.
- 5. Cescriotion of Packaging and Authorized Contents. Model Numoor. Fissile Class. Other Conditions and
References:
(a) Packaging (1) Model No.:
GE-1100 (2) Description Steel encased lead shielded shipping cask.
A double-walled steel cylinder protective jacket encloses the cask during transport.
It is bolted to a steel pallet.
The cask is closed by a lead-filled flanged plug fitted with a silic e. rubbcr gasket and bolted closure.
The physical description is as follows:
Cask height, in 30.6 Cask diameter, in 24.0 Cavity height, 'n 7.75 Cavity diameter, in 4.25 Lead shielding, in 9.4 Protective jacket height, in 43.9 Protective jacket width, in 40.75" Packaging veight, lbs 7,000 1
8008150l3*I
J.
Page 2 - Certificate No. 9046 - Revision No. 2 - Docket No. 71-9046 (3) Drawings The packaging is constructed in accordance with the following General Electric Company Drawing Nos.:
144F612, Rev. 3 10603992, Rev. 1 277E416, Rev. 1 10603991, Rev. 1 (b) Contents (1) Type and form of material (i) Byproduct material meeting special form requirements of 10 CFR
$71.4(o); or (ii) Solid nonfissile irradiated metal hardware.
(2) Maximum quantity of material per package Radioactive decay heat not to exceed 810 watts.
6.
Shoring shall be provided to minimize movement of contents during accident conditions of transport.
1 7.
Package contents shall be delivered to a carrier dry.
8.
Prior to each shipment the silicone rubber lid gasket shall be inspected.
This gasket shall be replaced if inspection shows any defects or every twelve (12) months, j
whichever occurs first.
9.
The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR 671.12(b).
10.
Expiration date: July 31, 1985.
l
4 l
Page 3 - Certificate No. 9046 - Revision No. 2 - Docket No. 71-9046 REFERENCES General Electric Company application dated April 22, 1980.
l Supplements dated:
February 20 and 27, 1969.
FOR THE U.S. NUCLEAR REGULATORY COMMISSION Charler; E. MacDonald, Chi Transportation Certification Branch Division of Fuel Cycle and Material Safety dyh 9 41990 Date:
i I
-l i
.,