Interim Deficiency Rept Re Bulging of Liner Plate.Corrective Action Consists of Removing Plate Around Penetrations, Wind Girder & Embedded Angles & Chipping Concrete.Analyses Continuing.Next Rept 770815.Related Correspondence
ML19338C071
Person / Time
Site: Midland
Issue date: 06/15/1977
From: Howell S
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To:
Shared Package
ML19338C066 List:
References
HOWE-100-77, NUDOCS 8007310653
Download: ML19338C071 (4)


Text

Y

~

+.a.

'-S '

p,n..,r.n..v.....

f aEarm q=w--l-1

/

l ytl,':;;*

..,,,... n.n..a r-e,. *,

IWlupai,3 oaneros offices: 212 West uschsgen Avenwo. Jackson.M.cNoen 4 0201 June 15,1977 eI Hove-100-77 N

g g

G

.h

)

5

$.g\\,s < %:=

l;4 i

.. y/

~

.Mr. J. G. Keppler, Regional Director Office of Inspection and. Enforce =ent 0' /

x US Nuclear Regulatory Cc= mission

',C, e

Region III N**

. 799 Roosevelt Road Glen Ellyn, IL 60137 i

MIDLAND UUCLEAR PLANT - UNIT NO. 2 LINER PLATE INTERIM REPORT - DOCKET NO. 50-330 On March 30, 1977 and May 16,1977, per 10CFR50 55(e), ve provided interim.

reports on the bul 1ng of the Unit No. 2 liner plate at the Midland site.

This 6

report is again an interim report in that the c'orrective action.and the safety implications of the correction to the liner plate and concrete have not been fully determined.

1 Since providing the May 16,19TI report, the following activities have been mcmpleted:

1.

Removing the 1/2" plate around the penetrations at azimuths 263 and 26'7 cud elevations 605'-0" and 609'-0".

2.

Re=t.' ring the leak chase channels at aziwths 250 and 270 and the remaining portions of the liner plate attached to tha W14 x 61 columns at those azimuths.

3.

Remgving the vind girder at elevation 670'-0 ' andi between azimuth 270 and 280 h.

Removin6 embedded angles and chipping concrete in parts of the exposed surface.

5 Removing two vindows in the liner plate near elevation 670' between azimuths 270 an.1 280 to allov inspection of the concrete vall where velds attaching the vi'.id girder to the liner plate caused small tears and puckering of the plate.

6.

Cutting an 8" x' h-1/2"- trench in the base slab at the bottom of the subject panel agd extending 6" on each side of the Wlh x 61 columns at azimuths 250 and 270 to determine the line of connection of the replacement panel at the

, bottom.

The. leak chase between the liner and knuckle plate at elevation 593' 8007320has been tested and found to hold the test pressure.

9~q3 g

m

. e"

/~

z

'Y

>r Howe-100-77 W

7

' Mapping the existin5 condition of the exposed surface of the concrete vall.

W rk is ' continuing to complete the evaluation of damage, the required tests and analyses, and the -definition of repair methods.

The iterative process of desi6n and developmental / qualification testing in combination with the time necessary.

to cure the concrete test specimens are the main reasons for the duration of this

. cffort.'

Since this is an' interim report, another report, either interim or final, vill be sent on or~.before August 15, 1977 M

s p

-Bluf/jmb CC:.Dr Ernst Volgenau (15)

US IBC, Washington, DC Director, Office of Management LInformation and Program Control

.US ImC, Washington,. DC e

i

.l l

~'

2

wr x =;m.=n2..C 1, 9.

(

y VL W o

....--w...

~.r w *~ n

'J....

o y N-stee! Iininc cama 6e!

'"N, w

t e

iS TO!Gden.i.nOi!C.fitiCG!

t

~

~

4

  1. N+

j

<..d-d

?

p gI./

.y

,the Midland site. to check progress of j "o

By ESTHER VAN WAGONER."IUFTY

. Washington correspondent the liner plate budge removal on Con. *

.j j. 4 v

5"

/

for Midland Daily News -

tainment Building 2 and to discuss the e

(/.

WASHINGTON 4e Advisory Com. raodification to the tendon sheath rout.;

E mittee on Reacto'r Safeguards. (ACRS). Ing on Containment Building 1.

j

% 1 * *.

' determined Friday that-damags to the.'This rerouting is necA Consumers Power spokesman sa Midla

  1. was.'nd nuclear plant's steel lining essary because ot ' critical-from. a. safety stand.. two presently installed tendon shesths.

point.

,. ere installed.hcrizontally under two

. n.s 2..

w A representative froMth0'm vr.

Nuifear "f.tainment wall penetrati ns instead L

Regulatory Commission. (NRC). Robert o m an arc. It has been determined.

E. Shewmaker outlined a.' repair pro that concrete around the two in,

grarn -for the damage ~to-the ACRS. correctly installed tendon sheaths will l, which met Friday morning.:. +pid.:. not have to be removed to provide Shewmaker said the. repair # proposal space for the two additional tendon j!

~

would' include-testingJ.which-is pow In sheaths called for by the original de.,

regress, and. that, repairs would ad, sjgn" herefor6..bzere will b ere to the plant s. original design..(."old costs and no. schedule impact. Since inimal It seems taepway4toJgo." hy t ACRS members, adding that the situa. there is still enough space below the '

tion is "not critical.".1-46 N two penetrations to install one ol the A bulge is!the stsel lineEp~ late Aur. tendon sheaths and the'.other tendon

~

rounding one-of the re:tetor buildings. sheath required by the original design can be lastalled ove was said to have been caused by a wa. errations, t.% ongs,e the top of the pen. ;

ter leak from a frozen pi nal,Mgn Mtda t age occurred in Fubruary:pe. The dam. I'# D' fontainment building wall wilt,

'~

ACRS member Wil!!am Kerr, profes. D' sor of nuclear engineering and director O

ursday, the Nuclear Regulatory

.. Commission and Consumers Power of the Michijtan Memortal Scenic prol.

ect at the Uruversity of Michigan." cited..m. anage. ment. met.at Jackson to discuss i 1 a.mily colo weather, saying under me tenu n snedu1Ini problem and to,

n.rmal weather conditions the pipe conurm that Consumers Power Com. i would have been protected. -

~- pany would implement the actions ree-l Kerr did' not appear alarmed about ommended by the Nuclear Regulatory :

the situation but expfessed surprue at Commission. During this meeting Con.

the cost of repair.

sumers Power indicated that all actions

  • Consumers Power Company officials recommended would be implemented ;

have estimated the cost of. repair at including an independent inspection by more than 3300.000.

Consumers Power Company until the in. ;

vestigatforr of the causes of the tendon !

sheath deficiencies and. corrective ac. !

At Consumers Power headquarters in tion thereto is completed by Consumers !

Jackson, n was pointed out that the Nu.

clear Regulatory. Commission visited Power Company and reviewed by the !

Nuclear RegulatoryCommission,.

.o..--~~..r...,,..,-

. :,. o.,..... e._....,..: g.e.

i 1

UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION Before the Atomic. Safety and Licensing Board In the Matter of

)

)

CONSUMERS POWER COMPANY

)

Docket Nos. 50-329

)

50-330 (Midland Plant, Units 1 and 2) )

PROOF OF SERVICE Peter A. Flynn, one of the attorneys for Intervenors other than Dow Chemical Company, certifies that:

1.

Copies of Intervenors' Proposed Findings of Fact and Conclusions of Law were served by Federal Express Messenger on the members of the Board and the Staff on June 30, 1977, and by personal delivery on counsel for Consumers Power Company and by first class mail to Dow Chemical Comp;ny on July 1, 1977; and 2.

That Intervenors ' Brief, Errata Sheet, Amended Motion to Permit Late Filing and Motion for the Receipt of Six

\\

Additional Exhibits in Evidence were served on the members of the Board by Federal Express Messenger, and on Consumers Power Company by personal delivery, and on the Staff and Dow Chemical Company.by first class mail, July 1, 977.

b W

Myron M. Cherry One of the Attornays for Intervenors Peter A. Flynn other than Dow ph6mical Company One IBM Plaza Suite 4501 Chicago, Illinois 60611 (312) 565-1177