TENNESSEE VAll.FY A.UTHORITY CH ATT A NCO 3 A. T E ' 'IF4 3 E E 37401 4M Chestnut Street Tower II October 3,1980 Mr. James P. O'Reilly, Director Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Region II - Suite 3100 101 Marietta Street Atlanta, Georgia 30303
Dear Mr. O'Reilly:
HARTSVILLE NUCLEAR PLANT UNIT A1 - REPORTABLE DEFICIENCY - CRACKS IN RPY SHIELD WALL (NCR HNP-A-091)
Initial notification of the subject deficiency was made to NRC-0IE, Region II, Inspector R. W. Wright on March 14, 1980. The first and second interim reports were submitted on April 14 and July 3, 1980, respectively. In compliance with paragraph 50.55(e) of 10 CFR Part 50, this is the third interia report on'the subject defic.'ency. We consider 10 CFR Part 21 applicable to this nonconformance.
TVA will 2epair the cracks in the RPV shield wall. TVA is awaiting GE's approval of the recommended disposition and repair procedures.
TVA anticipates transmitting the final report on or before January 1, 1981.
If yoin have any questions concerning this subject, please call Jim Domer at FTS 857-2014 Very truly yours, TENNESSEE VALLEY AUTHORITY L. M. Mills, Manager Nuclear Regulation and Safety ec:
Mr. Victor Stello, Director Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, DC 20555 bOS s
/ /0 2'
8 010070 '3