n a

s t

4 Q,/

e d

Form NAC418 U.S. NUCLEAR REGut.ATORY CCMMISSloN

'2[q CERTIFICATE OF COMPLIANCE 3

g For Radioactive Materials Packages 1.tal Certificats Number 1.fb) Revision No.

1.fcl Package Identification No.

1.fd ) Pages No. 1.fe) Total No. Pages 6581 13 USA /6581/B( )F 1

4

7. PREAMBLE

~

2.tal This certificate is issued to satisfy Sections 173.393a 173.394,173.395. and 173.396 of tne Ceoartment of Transportation Ha23rdous Materials Regulations 149 CFR 170189 and 14 CPR 103) and Sections 146-19-104 and 146-19-100 of tne Ceoartment of Transportation Cangerous Cargoes Regulations (46 CFR 146--149), as amended.

2.!b)

The packaging and contents described in item 5 below, meets the safety standards set forth in Suboart C of Title 10. Coce of Federal Regulations. Part 71 "Pacmaging of Radioactive Materials for Transp3rt and Transoortation of Radioactive Material Under Cartain Conditions /*

2.fc)

This certificate does not relieve ene consignor from comoliance with any reouirement of the requeations of tne U.S. Ceoartment of Transoortation or other acolicable regulatory.agenpes. inducing the government of any country througn or into annen the pacmage will be transoorted.

3. This certificate is is:ued on tne basis of a safety analysis reoort of the package design or aposication-3.f a)

Prepared by (Name and address):

3.V, "cle and a:fentification of recort or aoofication:

EXXON Nuclear Company, Inc.

EXXON Nuclear Company, Inc. application dated 2955 Geroge Washington Way June 15, 1979, as supplemented.

Richland, WA 99352 3.fc)

Oocket No.

7].4yJ 4 CONOtTIONS This certificate is conditional upon the fulfilling of the roouirements of Suboart O of '10 CFR 71, as apolicaolo, and tne conditions toeofied in item 5 below.

S. Gescription of Packageng and Autnonzad Contents. Model Nemmer. Fissile C: ass. Ctner Conditions, and

References:

(a) Packaging

)

(1) Model Nos.: 51032-1 and 51032-la (2) Description A steel shipping container for fuel bundles, consisting of a strongback and fuel bundle clamping assembly, shock mounted to a steel outer container. Minimum 3/8" thick wall, 6" x 8" x 8-1/2" long steel separators are bolted between fuel bundles.

Outer container is approximately 43" diameter by 216" long.

The maximum weight of the package is 7,400 pounds for the Model No. 51032-1 and 8,300 pounds for the Model No. 51032-la.

(3) Drawings The Model Nos. 51032-1 and 51032-la are constructed in accordance with EXXON Nuclear Company, Inc. Drawing Nos.:

XN-NF-303,359, Sheet 1, Rev. 1 XN-NF-303,360, Sheet 1, Rev. 1 XN-NF-303,364, Sheet 1, Rev. 1; and Package-separate block, shock mount, and fuel element clamp assembly requirements shall be in accordance with Tables 2-II thru 2-IX (pp 2-16 thru 2-23) of the application; and W

F Page 2 - Certificate No. 6581 - Revision No.13 - Docket No. 71-6581 s

5.

(a) Packaging (continued)

(3) Drawings (continued)

The Model No. 51032-1 is constructed in accordance with EXXON Nuclear Company, Inc. Drawing Nos.:

XN-NF-303,890, Sheet 1, Rev. 0 XN-NF-303,891, Sheet 1, Rev. 0 XN-300,609, Sheet 1, Rev. 1 XN-NF-303,898, Sheet 1, Rev. 0 XN-NF-303,897, Sheet 1, Rev. O and Jersey Nuclear Company Drawing Nos.:

JN-300,607, Sheet 1, Rev. 0 l

JN-600,843, Sheet 1, 2ev. 3 JN-600,844, Sheet 1, Rev. 2; or The Model No. 51032-la is constructed in accordance with EXXON Nuclear Company, Inc. Drawing Nos.:

XN-NF-303,354, Sheet 1, Rev. 2 XN-NF-303,357, Sheet 2, Rev. 1 XN-NF-303,355, Sheet 1, Rev.1 XN-NF-303,358, Sheet 1, Rev.1 XN-NF-303,356, Sheet 1, Rev. 1 XN-NF-303,818, Sheet 1, Rev. 0 XN-NF-303,357, Sheet 1, Rev.1 (b) Contents Type, form, and maximum quantity of material per package shall be as follows:

(1) UO r unpressurized (Atm pressure) Pu0 -UO fuel assemblies as follows:

2 2

2 Maximum No. of Radioactive Material Fissile Constitutents Assemblies per a

Fuel Type (kg/ Package)

(kg/ Package)

Package TYPE I U

362 U-235 7.6 2

Pu 2.5 Pu 2.0 f

TYPE II U

510 U-235 16.0 4

Pu 6.0 Pu 4.8 f

TYPE III U

510 U-235 23.0 4

Pu

6. 3 Pu 5.0 f

aSee Tables 2-XV thru 2-XIX and 12-XIV of application for the limiting physical characteristics of each fuel type.

l

Page 3 - Certificate No. 6581 - Revision No. 13 - Docket No. 71-6581

\\

5.

(b) Contents (continued)

Maximum No. of Radioactive Material Fissile Constitutents Assemblies per a

Fuel Type (kg/ Package)

(kg/ Package)

Package TYPE IV U

240 U-235 5.0 2

Pu 1.8 Pu 1.4 f

b A

U 700 U-235 24.5 2 or 4 B

U 1,500 U-235 52.5 2or[#

b C

U 1,500 U-235 60.0 2 or~4 b

0 U

1,500 U-235 60.0 2 or 4 D

E U

1,500 U-235 60.0 2 or 4 D

F U

1,500 U-235 75.0 2 or 4 c

AA U

1,100 U-235 38.5 2

bTwo (2) fuel elements of standard length or four (4) short elements of equivalent weight.

cAuthorized for shipment only in Model No. 51032-la container.

A single (1) fuel rod may be adoed to the above packaging in accordance with Paragraph 12.4.3.4 (pp 12-19 and 12-20) of the application.

(2) Sintered uranium oxide pellets as Zr clad fuel rods packaged within the inner wooden container described by EXXON Nuclear Company, Inc. Drawing No. XN-301,901, Rev. 1.

The package may contain up to nine (9) fuel rods having a maximum anrichment of 5.0 wt% U-235 with a maximum pellet diameter of 0.5 inches.

Inert Zr rods may be additionally included.

(c) Fissile Class I and III (1) Class I Types I, II, IV, A, B, and AA.

described and limited in 5(b)(1).

(2) Maximum number of packages (1) Types III, C, D, E, and F, per st.ipment as Class III assemblies described and limited in 5(b)(1);

Eight (8) packages (ii) For the contents described and limited in 5(b)(2)

One (1) package

Page 4 - Certificate No. 6581 - Revision No. 13 - Docket No. 71-6581 e

\\

6.

Each fuel assembly shall be enclosed in an unsealed polyethylene sheath which will not extend beyond the ends of the fuel assemblies.

The ends of the sheaths shall not be folded or taped in any manner that would prevent the flow of liquids into or out of the sheathed fuel assemblies.

Polyethylene shims and ethafoam pads may be used in the packaging of fuel assemblies in accordance with p. 2-6 and Table 12-XIV of the application.

7.

The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR 571.12(b).

8.

Expiration date:

July 31,1985.

l REFERENCES EXXON Nuclear Company, Inc. application dated June 15, 1979.

Supplements dated:

November 30, 1979; and June 13 and August 6 and 15, 1980.

FOR THE U.S. NUCLEAR REGULATORY COMMISSION f/

- f Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety ~

SEP 2 219c0 Date: