Text
f<
h" " ^ O Ef*...%'o, UNITED STATES.
g' g -
g' NUCLEAR REGULATORY COMMISSION E-WASHINGTON, D. C. 20656 :
0>
l DEC 11 198g
. NOTE-TO:1 D. Lanham NUDOCS FROM:
Hazel Smith
SUBJECT:
R. LICCIARD0'S DPV PERTAINING TO ZION (TAC.73427)
The following correspondence is enclosed for your inclusion in the Public Document Room and Central Files:
1..
MemoranGum dated-10/30/89 from R. Jones to R. Licciardo transmitting o
a copy of the following_ document, which is to ensure that pressure and temperature effects during a LOCA are considered in the review of new and advanced fuel designs:
(
Memorandum dated 10/25/89 from R. Jones to Reactor Systems Branch Engineers. entitled, " Branch Review Guidance: Review of Fuel Pin-J Parameters for LOCA Analyses."
2.
Memorandum dated 11/30/89 from T.'Murley (signed by J. Sniezek) to l:
R. Licciardo stating-that NRR will not issue its evaluation of the l'
proposed tech specs for Zion containment purge and vent system until l
the group headed by Dr. Ross completes its review of the DP0 l
pertaining to this. issue.
Hazel Smith, NRR
Enclosures:
As stated cc w/o'encls:
'F. Miraglia F. Giliespie J. Craig R. Jones
-l R. Licciardo J. Larkins V. Wilson gg 1$e; e oos 5
W* \\
1
,m y
s-M
)
2-9 3
..,,,,, g W[
S
%j UNITE D STATES NUCLE AR REGULATORY COMMISSION
' \\, '
W i
is k-
{
l wAssiwovow. o. c. rosss J
- g...../
NOV 3 01S53 4
MEMORANDUM FOR: Robert B. A. Licciardo, Reactor Engineer (Nucleer)
Plant Systems Branch Division of Systems Technology FROM:
Thomas E. Murley, Director Office of Nuclear Reactor Regulation
SUBJECT:
DIFFERING PROFESSIONAL OPINION in my September 13, 1989 memorandum, Item I stated that the staff should issue its evaluation of the proposed Zion Technical Specifications for i
containment purge and vent system. This amendment was expected to be issued l
by November 30, 1959.
The licensee provided a new submittel on November 21, 1989. However, this submittal is significantly different from the original submittal. Therefore, the submittal will be renoticed in the Federal. Register. The staff's i
evaluation of the revised submittal is expecteo by January 15, 1990. However, l
since this issue is now being reviewed as a Differing Professionel Opinion, final staff action on the licensee's request will not be taken until the l
review group headed by Dr. Ross completes its review of this issue.
gw.a k a4f
'T 1omas E. Murley, Ditjecto ffice of Nuclear Reactor Regulation cc:
J. Taylor i
D. Ross F. Miraglia F. Gillespie CONTACT:
John W. Craig, NRR/PD32 49-21395 i(0~
J
,