ML19332C359

From kanterella
Jump to navigation Jump to search
Exam Rept 50-002/OL-89-01 on 891030.Exam Results:Three Reactor Operator Candidates Passed Exams
ML19332C359
Person / Time
Site: University of Michigan
Issue date: 11/13/1989
From: Jordan M, Shepard D
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
Shared Package
ML19332C357 List:
References
50-002-OL-89-01, 50-2-OL-89-1, NUDOCS 8911280021
Download: ML19332C359 (8)


Text

,,

i:.i

.3 3

[

1 U.S. NUCLEAR REGULATORY COMMISSION REGION III tn Report No.' 50-002/0L-89 Docket No. 50-002-License No. R-28 Licensee: Michigan Memorial Phoenix Project c

University of Michigan L

~ Ann Arbor, Michigan Facility Name:

Ford Nuclear Reactor

.z

. Examination AdministeredAt: University of Michigan Examination Conducted: Week of October 30, 1989 Chief Examiner:-

Mk

//[lhM -

D. Sh(pard ~

Date Approved By:?

N!/ 3 7

M.~Jor#ani Ehief Date Operafor/ Licensing Section 1 Examination Sunnary 1

Examination administered during the week of October 30, 1989 (Report No. 50-002/

OL-89-01) to five reactor operators and one senior reactor operator candidates.

-Results:

-Three reactor operator candidates passed the examinations.

8911280021 891116 PDR ADOCK 05000002 V

PDC

.u-e 4

REPORT DETAILS 1.

Examiner D. Shepard, Chief Examiner 2.

Exit Meeting h

An exit meeting was held with R. R. Burns (Reactor Manager), G. Cook (Assistant Manager for Operations), and the Chief Examiner on November 2, 1989. No generic concerns were raised.

The facility examination coments were discussed as noted in Enclosure 2.

t 4

F 2

.e
gq 15 4

Facility Comments and NRC Resolution of Comments

~

QUESTION A.01 Q 00).

I Which:0NE of-the,following is correct concerning the effects of increasing the i,

moderator to fuel rr,tio?

'a.

Thermal: utilization factor increases, b.

Reson nca escape probability decreases.

c.

-Reproduction factor increases.

[

d.

Fast. fission factor increases.

~ ANSWER:

-a.

FACILITY COMMENT:

None of the answers provided is correct. As moderator to fuel ratio increases, therma 1' utilization factor decreases because the additional moderator is an absorber;that competes with fuel for neutrons. The question.should be removed from the examination.

.HRC RESOLUTION:

Concur, question. deleted.

QUESTION A.02 (1.00)-

Which ONE of the following is correct with respect to voids?

a.

An increase in the void concentration decreases Keff due to a decrease in

.the fast fission factor.

+

b.

An increase in the void concentration increases Keff due to an increase in the resonance escape probability, c.-

A decrease in the void concentration decreases Keff due to an decrease in the fast non-leakage probability.

d.

A decrease in the void concentration increases Keff due to an increase in the' thermal utilization factor.

E v

L 2

r

' ANSWER:

d.

L FACILITY COMMENT:

[

None of the answers provided is correct. As void concentration decreases, moderator to fuel ratio increases. Thermal utilization factor decreases f-because the additional moderator is an absorber that competes with fuel for-F neutrons. The questions should be removed from the examination.

NRC RESOLUTION:

Concur, question deleted.

QUESTION A.08 (1.00)

Which ONE of the following power levels is the highest power level at which the reactor can be operated while in the natural convection mode (assume all systems operate as designed)?

a.-

1 watt b.

10 kw c.

100 kw d.

1 MW ANSWER:

b.

FACILITY COMMENT:

Every licensed operator including myself missed this question when we reviewed-the examination. After the fact, we realized that the scram setpoint is 100 kw so the reactor could not be operated at that level. This question is a trick that has-no operations importance. We object to such questions when everyone knows the power limit in natural convection is 100 kw. The question should be removed from the examination.

p y

s 3

NRC RESOLUTION:

Question deleted. Do not concur that the question was a trick question.

It did require using more than one piece of information to be synthesized vice rote recall. In the multiple choice format for a question to be effective, it is' required to use synthesis and the higher cognitive levels of knowledge.

The question is deleted since it is possible for the thermal power to be 100 kw and not cause a' scram due to movable detectors. Assumption must be made that setpoint is per technical specifications.

QUEETION A.18 (1.00)

Which ONE of the following is closest to the reactor period expected after 20 seconds, if a rod was inserted with a reactivity of -0.005 delta K/K?

a.

-0.995 minutes b.

- 8 seconds c.

-48 seconds d.

-80 seconds ANSWER:

d.

FACILITY COMMENT:

A reactivity insertion of -0.005 delta K/K is a substantial amount of reactivity; about 1-1/2 of our control rod. While the final stable period following the insertion would be -80 seconds, it would take about three minutes to reach that value which is the time needed for all delayed neutron precursors except Br-87 to decay away. During the transition, the period would vary from short to the final value of -80 seconds; the exact value after 20 seconds would be difficult to precisely determine. Answers a. and c. would be closer to the actual value than answer d.

Either answers a.,

c., and d. should all be accepted or the question should be eliminated.

NRC RESOLUTION:

Concur, question deleted. An experiment done by the facility resulted in a period of -65 seconds as discussed in the exit meeting.

Nei

.1 q

[:% 4f li

.l, 94 5. :

e i

4

. Enclosure 2

+

i^

-QUESTION-.19'(1.00)

The~ doppler is'NOT significant for;the FNR:because of the...

l

_a.

3.' plate type fuel that.is used.

p g

b.;

...-small amount of10-238 in the fuel.

a c.-

-,.. control rod configurations.

d;.

... low operating power levels.

l3 ANSWER:-

b.

' FACILITY COMMENT:

The' answer is correct,J but we do not have-any mention of doppler and doppler coefficient in our training material. Our trainees cannot be held responsible for material.thatiis'not part-of our program. At the last examination, we were told.that there would never be anoth~er doppler question on one of our

' examinations'._ Deleteithe question from the examination.

7

'NRC: RESOLUTION:.

4

.This question was deleted due to low safety significence.

It should be noted, however, that the knowledge elicited by this question was provided in your

. training' material-(Introduction to Nuclear Reactor Operations, Page 4-6, "the

effect.(doppler) is not seen in the FNR because of the very low uranium density-in the. fuel...")

QUESTION B.10 (1.00)

Which ONE of the following rooms would a 50 R/hr Ion Chamber be found?

L a.

1030L b.

.2036 c.

2051-d.

2105 l

l l

l l

s

W e

y* * -

l4m

,y;.

5 s

ANSWER:

V

(.~

c, FACILITY COMMENT:

7 We do not require our operators to memorize room numbers. The correct answer is the emergency closet. We request that you eliminate the question.

If you will not do that, at least accept answers b and c because we could reasonably expect the operators to know the emergency closet is on the second floor of the building.

NRC RESOLUTION:

Concur, question deleted.

t QUESTION C.12 (1.00)

Usins the attached figure 13.1, which ONE of the following sets of conditions must be met to withdraw A shim safety rod (assume all other requisite conditions associated with the-rod withdrawal are met)?

LIGHTS 41 31 40 36 shim range shim upper B mag lower a.

OUT LIT LIT OUT b.

OUT LIT LIT LIT c.

LIT OUT OUT LIT d.

LIT OUT LIl OUT ANSWER:

-c.

FACILITY COMMENT:

The correct answer is d.

Answer c. is incorrect because it specifies that light 40, A shim rod magnet contact light, is out.

If that were the case, the rod would not be in contact with its magnet and would not withdraw when thu rod-drive mechanism was moved. Answer d. is a normal operating condition for withdrawing A rod. Withdrawal permit is actuated because A rod is in shim range. A rod is not in its upper limit and we have magnet contact.

)

,$,I.Ae u

L 4.

.~

F 6

i

- NRC RESOLUTION:-

Concur, answer key modified to accept d. as the correct answer.

f 4

f I

i 6

Y P

t

... _... _. _