Notice of Violation from Insp on 800721-25
ML19332B392
Person / Time
Site: Davis Besse 
Issue date: 08/18/1980
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
Shared Package
ML19332B391 List:
References
50-346-80-24, NUDOCS 8009260661
Download: ML19332B392 (1)


Text

.

O Appendix A NOTICE OF VIOLATION Toledo Edison Company Docket No. 50-346 Based on the inspection conducted on July 21-25, 1980, it appears that certain of your activities were in noncompliance with NRC requirements, as noted below.

Items 1 through 4 are deficiencies.

1.

Section 2.1.1 of the Appendix B Environmental Technical Specifications re-quires, inpart, that "The maximum discharge temperature for station liquid effluents shall not exceed 20*F above ambient lake water temperature."

Contrary to the above, the 20*Fo T limit was exceeded on January 6, 7, 8, 16, and February 20, 1980.

2.

Section 5.4.2 of the Appendix B Levironmental Technical Specifications requires, in part, that "A report shall be submitted in the event that a limiting condition for operation is exceeded (as specified in Section 2, " Limiting Conditions for Operation")..." Section 2.1.1 of the Appendix B Environmental Technical Specifications states "The maximum discharge temperature for station liquid effluents shall not exceed 20 F above ambient lake water temperature."

Contrary to the above, although the 20*F aT limit was exceeded on February 20, 1980, (aT=20.62*F at 0100, AT=22.09*F at 0200,41=20.01*F at 0300, and aT=20.54*F at 0800), no report was submitted.

3.

Section 2.3.3 of the Appendix B Environmental Technical Specifications requires, in part, that "The concentration of sulfate ion shall be determined once per week from a grab sample collected at the beach sampling station during the discharge of the neutralizing tank.

If there is no discharge from the neutralizing tank, sampling shall be once per week."

Section 1.0 of the Appendix B Environmental Technical Specifications defines a week as "At least once every seven days with a maximum allowable extension of 25%."

Contrary to the above, no sulfate monitoring was performed between February 12, 1979 and February 23, 1979, a period of time longer than seven days plus 25%.

4.

Section 3.1.2.a.4 of the Appendix B Environmental Technical Specifica-tions requires, in part, the "Ichthyoplankton samples shall be taken once every ten days during the anticipated spawning season, April through August," and " Duplicate samples surface and bottom shall be collected in the vicinity of...the Toussaint Reef.

Samples at the Toussaint Reef shall be collected only during the anticipated spawning season."

Contrary to the above, no sampling was conducted at the Toussaint Reef between June 1, 1980, and June 30, 1980, a period of time in excess of ten days.