Category:MONTHLY OPERATING ANALYSIS REPORT
MONTHYEARML20101E5761992-05-31031 May 1992 Monthly Defueling Operations Rept for May 1992 for Fort St Vrain ML20096E8221992-04-30030 April 1992 Monthly Operating Rept for Apr 1992 for Fort St Vrain.W/ ML20100R7431992-03-31031 March 1992 Monthly Operating Rept for Mar 1992 for Fort St Vrain.W/ ML20090L0621992-02-29029 February 1992 Monthly Operating Rept for Feb 1992 for Fort St Vrain Unit 1 ML20092D0081992-01-31031 January 1992 Monthly Operating Rept for Jan 1992 for Fort St Vrain Nuclear Generating Station ML20091J6251991-12-31031 December 1991 Monthly Operating Rept for Dec 1991 for Fort St Vrain.W/ ML20094D6711991-11-30030 November 1991 Monthly Operating Rept for Nov 1991 for Fort St Vrain Unit 1 ML20086C5451991-10-31031 October 1991 Monthly Operating Rept for Oct 1991 for Fort St Vrain.W/ ML20085D9861991-09-30030 September 1991 Monthly Operating Rept for Sept 1991 for Fort St Vrain.W/ ML20082U6151991-08-31031 August 1991 Monthly Operating Rept for Aug 1991 for Fort St Vrain Unit 1 ML20082J0071991-07-31031 July 1991 Monthly Operating Rept for Jul 1991 for Fort St Vrain,Unit 1 ML20076C5621991-06-30030 June 1991 Monthly Operating Rept for June 1991 for Fort St Vrain.W/ ML20077F8391991-05-31031 May 1991 Monthly Operating Rept for May 1991 for Fort St Vrain ML20077C2591991-04-30030 April 1991 Monthly Operating Rept for Apr 1991 for Fort St Vrain ML20084U7831991-03-31031 March 1991 Monthly Operating Rept for Mar 1991 for Fort St Vrain ML20070P4811991-02-28028 February 1991 Monthly Operating Rept for Feb 1991 for Fort St Vrain.W/ ML20066G5561991-01-31031 January 1991 Monthly Operating Rept for Jan 1991 for Fort St Vrain Unit 1 ML20070A5841990-12-31031 December 1990 Monthly Operating Rept for Dec 1990 for Fort St Vrain Unit 1 ML20065R0331990-11-30030 November 1990 Monthly Operating Rept for Nov 1990 for Fort St Vrain Unit 1 ML20058H8821990-10-31031 October 1990 Monthly Defueling Operations Rept for Oct 1990 for Fort St Vrain Nuclear Generating Station ML20197H8721990-10-31031 October 1990 Monthly Operating Rept for Oct 1990 for Fort St Vrain.W/ ML20059P0661990-09-30030 September 1990 Monthly Operating Rept for Sept 1990 for Fort St Vrain Nuclear Generating Station ML20059J1061990-08-31031 August 1990 Monthly Defueling Operating Rept for Aug 1990 for Fort St Vrain ML20058Q1661990-07-31031 July 1990 Monthly Operating Rept for Jul 1990 for Fort St Vrain ML20043G1141990-05-31031 May 1990 Monthly Operating Rept for May 1990 for Fort St Vrain. W/900615 Ltr ML20043A1121990-04-30030 April 1990 Monthly Operating Rept for Apr 1990 for Fort St Vrain. W/900515 Ltr ML20042E6421990-03-31031 March 1990 Monthly Defueling Operations Rept for Mar 1990 for Fort St Vrain.W/900413 Ltr ML20006F5441990-01-31031 January 1990 Monthly Defueling Operations Rept for Jan 1990 for Fort St Vrain.W/900215 Ltr ML19354E0791989-12-31031 December 1989 Monthly Operating Rept for Dec 1989 for Fort St Vrain, Unit 1.W/900112 Ltr ML19351A6521989-11-30030 November 1989 Monthly Operating Rept for Nov 1989 for Fort St Vrain, Unit 1.W/891206 Ltr ML19351A6531989-10-31031 October 1989 Monthly Operating Rept for Oct 1989 for Fort St Vrain, Unit 1.W/891206 Ltr ML19327B1821989-09-30030 September 1989 Monthly Defueling Operating Rept for Sept 1989 for Fort St Vrain Nuclear Generating Station ML20247H2111989-08-31031 August 1989 Monthly Operating Rept for Aug 1989 for Fort St Vrain ML20245L5831989-07-31031 July 1989 Monthly Operating Rept for Jul 1989 for Fort St Vrain Nuclear Generating Station ML20246Q2241989-06-30030 June 1989 Monthly Operating Rept for June 1989 for Fort St Vrain Unit 1 ML20245C4471989-05-31031 May 1989 Monthly Operating Rept for May 1989 for Fort St Vrain ML20247A8961989-04-30030 April 1989 Monthly Operating Rept for Apr 1989 for Fort St Vrain Nuclear Generating Station ML20244E2151989-03-31031 March 1989 Monthly Operating Rept for Mar 1989 for Fort St Vrain ML20236C3731989-02-28028 February 1989 Monthly Operating Rept for Feb 1989 for Fort St Vrain Nuclear Generating Station ML20235J6181989-01-31031 January 1989 Monthly Operating Rept for Jan 1989 for Fort St Vrain Nuclear Generating Station ML20206F6871988-10-31031 October 1988 Monthly Operating Rept for Oct 1988 for Fort St Vrain Nuclear Generating Station ML20207N3841988-09-30030 September 1988 Monthly Operating Rept for Sept 1988 for Fort St Vrain ML20154H5331988-08-31031 August 1988 Monthly Operating Rept for Aug 1988 for Fort St Vrain.W/ ML20151V7821988-07-31031 July 1988 Monthly Operating Rept for Jul 1988 for Fort St Vrain Unit 1 ML20151E8951988-06-30030 June 1988 Monthly Operating Rept for June 1988 for Fort St Vrain ML20196C0671988-05-31031 May 1988 Monthly Operating Rept for May l988 for Fort St Vrain Nuclear Generating Station ML20154C2741988-04-30030 April 1988 Monthly Operating Rept 171 for Apr 1988 ML20151G1941988-03-31031 March 1988 Monthly Operating Rept for Mar 1988 ML20153B1361988-02-29029 February 1988 Monthly Operating Rept for Feb 1988 ML20149F8441988-01-31031 January 1988 Monthly Operating Rept 168 for Jan 1988 1992-05-31
[Table view] Category:TEXT-SAFETY REPORT
MONTHYEARML20196G6731997-07-0101 July 1997 Informs Commission That Decommissioning Process Has Been Completed at PSC of Colorado Fsvngs,Unit 1 Located in Town of Platteville in Weld County,Co ML20141K9961997-05-0505 May 1997 Safety Evaluation Supporting Amend 89 to License DPR-34 ML20140E1121997-04-10010 April 1997 Confirmatory Survey of Group Effluent Discharge Pathway Areas for Fsv Nuclear Station,Platteville,Co ML20134D1661997-01-30030 January 1997 Rev 1,Vol 6 to Final Survey Rept,Final Survey of Group E (Book 2A of 2) ML20137S6111996-12-31031 December 1996 Annual Rept Pursuant to Section 13 or 15(d) of Securities Exchange Act 1934, for Fy Ended Dec 1996 ML20134G6401996-10-29029 October 1996 Rev 0,Volume 6,Books 1 & 2 of 2 to Final Survey of Group E ML20134G6171996-10-29029 October 1996 Rev 2,Volume 1,Books 1 & 2 of 2 to Final Survey Description & Results ML20134G7271996-10-29029 October 1996 Rev 0,Volume 11,Book 1 of 1 to Final Survey of Group J ML20134G6861996-10-29029 October 1996 Rev 0,Volume 8,Books 1 & 2 of 2 to, Final Survey of Group G ML20134G6321996-10-26026 October 1996 Rev 1,Volume 5,Books 2 & 3 of 3 to Final Survey of Group D ML20133D7831996-10-22022 October 1996 Preliminary Rept - Orise Support of NRC License Insp at Fsv on 960930-1003 ML20116A4661996-07-19019 July 1996 Fsv Final Survey Exposure Rate Measurements ML20112J6861996-05-31031 May 1996 June 1996 Quarterly 10CFR50.59 Rept of Changes,Tests & Experiments for Fsv Decommissioning.Rept Covers Period of 960216-0531 ML20112C1531996-05-17017 May 1996 Fsv Final Survey Exposure Rate Measurements ML20101G5521996-03-21021 March 1996 Confirmatory Survey Activities for Fsv Nuclear Station PSC Platteville,Co, Final Rept ML20097E3201996-01-31031 January 1996 Nonproprietary Fort St Vrain Technical Basis Documents for Piping Survey Instrumentation ML20095K4131995-12-26026 December 1995 Rev 3 to Decommissioning Plan ML20095H7211995-12-20020 December 1995 Revs to Fort St Vrain Decommissioning Fire Protection Plan Update ML20095K9751995-12-15015 December 1995 Fort St Vrain Project Update Presentation to NRC, on 951207 & 15 ML20096C1671995-12-13013 December 1995 Rev 4 to Decommissioning Fire Protection Plan ML20094M1651995-11-30030 November 1995 Nonproprietary Fsv Technical Basis Documents for Piping Survey Implementation ML20092F3461995-09-14014 September 1995 Quarterly 10CFR50.59 Rept of Changes,Tests & Experiments for Fsv Decommissioning, Covering Period of 950516-0815.W/ ML20137H3531994-12-31031 December 1994 Partially Withheld, Rept of Independent Counsel Investigation Concerning Issues at Fort St Vrain Nuclear Generating Station Decommissioning Project, App D,Comments by Mkf & Westinghouse Team & Responses ML20137S2331994-12-31031 December 1994 Rept of Independent Counsel Investigation Concerning Issues at Fort St Vrain Nuclear Generating Station Decommissioning Project, Dec 1994 ML20029C6031993-12-31031 December 1993 1993 Annual Rept Public Svc Co of Colorado. W/940405 Ltr ML20058Q3791993-12-21021 December 1993 Rev 1 to Decommissioning Plan for Fort St Vrain Nuclear Generating Station ML20045B3641993-06-30030 June 1993 June 1993 Quarterly 10CFR50.59 Rept of Changes,Tests & Experiments for Fsv Decommissioning. ML20045A4291993-06-0303 June 1993 LER 93-003-00:on 930505,new Source of Natural Gas Introduced within 0.5 Miles of ISFSI & Reactor Bldg W/O Prior NRC Approval.Caused by Field Routing of Natural Gas Pipe.Well Isolated by Well operator.W/930603 Ltr ML20077D1631993-05-10010 May 1993 Enforcement Conference, in Arlington,Tx ML20125C7161992-12-0707 December 1992 Part 21 Rept Re Possibility for Malfunction of Declutching Mechanisms in SMB/SB-000 & SMB/SB/SBD-00 Actuators. Malfunction Only Occurs During Seismic Event.Balanced Levers May Be Purchased from Vendor.List of Affected Utils Encl ML20128D7191992-12-0101 December 1992 Safety Evaluation Approving Exemption from Requirement of 10CFR50.54(q) to Change to Biennial Emergency Plan Exercise Rather than Annual Following Completion of Next Scheduled Exercise at Plant ML20127P5861992-11-23023 November 1992 Followup to 921005 Part 21 Rept Re Potential Defect in SB/SBD-1 Housing Cover Screws.Procedure Re Replacement of SBD-1 Spring Cover Bolts Encl.All Fasteners Should Be Loosened & Removed.List of Affected Utils Encl ML20127F5691992-11-0303 November 1992 Informs Commission of Intent to Issue Order Approving Plant Decommissioning Plan & Corresponding Amend to License DPR-34 ML20101E5761992-05-31031 May 1992 Monthly Defueling Operations Rept for May 1992 for Fort St Vrain ML20096E8221992-04-30030 April 1992 Monthly Operating Rept for Apr 1992 for Fort St Vrain.W/ ML20095E9601992-04-17017 April 1992 Rev to Fort St Vrain Proposed Decommissioning Plan ML20100R7431992-03-31031 March 1992 Monthly Operating Rept for Mar 1992 for Fort St Vrain.W/ ML20090L0621992-02-29029 February 1992 Monthly Operating Rept for Feb 1992 for Fort St Vrain Unit 1 ML20092D0081992-01-31031 January 1992 Monthly Operating Rept for Jan 1992 for Fort St Vrain Nuclear Generating Station ML20102B2241992-01-22022 January 1992 Fort St Vrain Station Annual Rept of Changes,Tests & Experiments Not Requiring Prior Commission Approval Per 10CFR50.59, for Period 910123-920122 ML20094N6701991-12-31031 December 1991 Public Svc Co Annual Financial Rept for 1991 ML20091J6251991-12-31031 December 1991 Monthly Operating Rept for Dec 1991 for Fort St Vrain.W/ ML20094D6711991-11-30030 November 1991 Monthly Operating Rept for Nov 1991 for Fort St Vrain Unit 1 ML20090M1871991-11-20020 November 1991 FOSAVEX-91 Scenario for 1991 Plant Exercise of Defueling Emergency Response Plan ML20086D6891991-11-15015 November 1991 Proposed Decommissioning Plan for Fort St Vrain Nuclear Generating Station ML20085N1451991-11-0505 November 1991 Revised Ro:Operability Date of 910830 for Electric Motor Driven Fire Water Pump P-4501 Not Met.Pump Not Actually Declared Operable Until 911025.Caused by Unforseen Matl & Testing Problems.Equivalent Pump Available ML20086C5451991-10-31031 October 1991 Monthly Operating Rept for Oct 1991 for Fort St Vrain.W/ ML20085H6611991-10-10010 October 1991 Assessment of Mgt Modes for Graphite from Reactor Decommissioning ML20091D7671991-10-0101 October 1991 Rev B to Engineering Evaluation of Prestressed Concrete Reactor Vessel & Core Support Floor Structures for Proposed Sys 46 Temp Change ML20085D9861991-09-30030 September 1991 Monthly Operating Rept for Sept 1991 for Fort St Vrain.W/ 1997-07-01
[Table view] |
Text
9
[h
'\ )
This report contains the highlights of the Fort St. Vrain, Unit No. I activi-ties, operated under the provisions of the Nuclear Regulatory Commission Oper-ating License, DPR-34 This report is for the month of March,1980.
1.0 NAPA\TIVE
SUMMARY
OF OPERATING EXPERIENCE AND MAJOR SAFETY RELATED MAINTEMANCE 1.1 Summary At the beginning of this period, preparations were made for plant startup. On March 5,1980, at 0250 hours0.00289 days <br />0.0694 hours <br />4.133598e-4 weeks <br />9.5125e-5 months <br />, the turbine generator was synchronized and the electric load increased to eighty mega-watts. On March 6,1980, the turbine generator actual overspeed tests were performed. The unit was resynchronized af ter the test, and the electrical load was increased to one hundred megawatts.
Excessive oxidant contaminants in the primary coolant helium, as well as various control system problems caused the electrical load capability to be somewhat variable over the next seversi days of operation.
1.2 Operations Early in the morning of March 11, 1980, the east side return water distribution header on the main cooling tower ruptured. Large amounts of circulating water spilled over the distribution box near the rup-ture onto the ground. The yard drainage system in this area did not have the capability to handle this quantity of water, resulting in the water level in the surrounding area to reach a depth of several inches. Some of this water entered the manhole containing cables and associated conduits for the circulating water pump system. This water damaged several electrical motors of the circulating system.
The main turbine generator was tripped and the reactor scra=ced when it was evident that condenser vacuum could not be maintained.
Repairs were made and the reactor was brought critical again on the same day, but because of the damage to the circulating water pu=ps and the loss of acceptable feedwater chemistry, reactor power could not be increased above two percent until March 15, 1980.
On March 16, 1980, the "nu=ber two" auxiliary boiler tripped of f the line f rom undetermined causes. During the atte=pt to start " number one" auxiliary boiler, some boiler tubes were damaged due to low water level in the drum which rendered " number one" boiler inoperable.
" Number two" boiler was repaired and restarted af ter this occurrence. I The turbine generator was synchronized on March 16,19S0, and load was grcdually increased to two hundred thirty megawatts on March 13 and remained at that level until March 21, 19S0.