ML19332A868

From kanterella
Jump to navigation Jump to search
Forwards QA Program Insp Rept 99900245/80-01 on 800421-22 & Notice of Deviation
ML19332A868
Person / Time
Issue date: 05/09/1980
From: Potapovs U
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Richard Anderson
J.E.LONERGAN CO.
Shared Package
ML19332A858 List:
References
REF-QA-99900245 NUDOCS 8009180500
Download: ML19332A868 (2)


Text

...

in~

G mHW HCs

~~

UNITED STATES

[e' *%,%

NUCLEAR REGULATORY COMMISSION

"((i.NT EsYe'Y2

.T o

p--

/

-0 9 MAY 1980 Docket No. 99900245/80-01 J. E. Lonergan Company Attn: Mr. R. M. Anderson President Red Lion Road West of Verrie Road Philadelphia, Pennsylvania 19115 Gentlemen:

This refers to the QA Program inspection conducted by Mr. William D. Kelley, of this office on April 21-22, 1980, of your facility at Philadelphia, Pennsylvania, associated with the manufacture of ASME Section III "NV" Class 1, 2, and 3 safety and safety relief valves and to the discussions of our findings with Mr. W. A. Roach, Jr. and members of your staff at the con-clusion of the inspection.

This inspection was made to confirm that, in the areas inspected, your QA Program is being effectively implemented. The inspection effort is not designed to assure that unique quality requirements imposed by a customer are being implemented; nor to ascure that a specific product, component or service provided by you to your customers, is of acceptable quality. As-you know, the NRC requires each of its licensees to assume full responsibility for the quality of specific products, components or services procured.from others.

You should therefore not conclude that the NRC's inspection exempts you from inspections by an NRC licensee or his agents nor from taking effective cor-rective action in response to their findings.

Areas examined and our findings are discussed in the enclosed report. Within these areas, the inspection consisted of an examination of procedures and representative records, interviews with personnel, and observations by the inspector.

During the inspection it was found that the implementation of your QA Program failed to meet certain NRC requirements. The specific findings and references to the pertinent requirements are identified in the enclosures to this letter.

Please provide us within thirty (30) days of your receipt of this report a written statement containing, -(1) a description of steps that. have been or will be taken to correct these items, g2) a description of steps that have been or will be -taken to prevent recurrence, and (3) the date your corrective actions and preventive measures were or will be completed.

.8 0 0118 0 5dPC

J. E. Lonergan Company 2

In accordance with Section 2.790 of the Commission's " Rules of Practice,"

Part 2, Title 10, Code of Federal Regulations, a copy of this letter with enclosure and your reply, together with the enclosed inspection report will be placed in the Commission's Public Document Room.

If this report contains any information that you believe to be proprietary, it is necessary that you make a written application within thirty (30) days to this office to withhold such information from public disclosure. Any such application must include a full statement of the reasons on the basis of which it is claimed that the infonna-

_ tion 1:, proprietary, and should be prepared so that proprietary information identified in the application. is contained in a separate part of the document.

If we do not hear from you in this regard within the specified period, the report will be placed in the Publ.ic Document Room.

Should you have any questions concerning this inspection, we will be pleased,

to discuss them with you.

Sincerely, DW Uldis Potapovs, Chief Vendor Inspection Branch

Enclosures:

1.

Notice of Deviation 2 ~.

Inspection Report No. 99900245/00-01 c