Responds to IE Bulletin 79-03A, Longitudinal Weld Defects in ASME SA-312,Type 304 Stainless Steel Pipe. No Piping as Yet Installed at Facility
ML19331E432
Person / Time
Site: Bailly
Issue date: 08/14/1980
From: Shorb E
NORTHERN INDIANA PUBLIC SERVICE CO.
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
IEB-79-03A, IEB-79-3A, NUDOCS 8009100165
Download: ML19331E432 (1)


Text

___ _________________ ____ _.

b O

~"

Northern Indiana Public Service Compang General Offces l 5265 H# man Avenue l Hammond. Inchana 46325 l Tel.: 853-5200 (219)

EUGENE M. SHoRS m r v.cc aacsiorm August 14, 1980 Mr. James G. Keppler, Regional Director U. S. Nuclear Regulatory Commission Region III 799 Roosevelt Road Glen Ellyn, Illinois 60137 RE: Docket No. 50-367 IE Bulletin 79-03A, " Longitudinal Weld Defects in ASME SA-312, Type 304 Stainless Steel Pipe"

Dear Mr. Keppler:

This is in response to NRC IE Bulletin 79-03A dated April 4,1980.

Northern Indiana Public Service Company's (NIPSCO's) Bailly Gen-erating Station Nuclear 1 (BGSN-1) construction is less than one per

' cent complete. There has been no piping installed. Construction as well as engineering on BGSN-1 has been halted for nearly three (3) years awaiting completion of NRC review of the BGSN-1 pile founda-tion. Accordingly, NIPSCO cannot make determination at this time as to whether SA-312 or A-312 Type 300 Series fusion welded pipe is planned to be used in the BGSN-1 facility.

NIPSCO will respond to this Bulletin as soon as practicable following l resumption of engineering and construction on BGSN-1, or by January 4,1982.

Very truly yours, v -

EMS: cgs cc: U. S. Nuclear Regulatory Commission Office of Inspection & Enforcement Division of Reactor Construction Inspection Washington, D. C. 20555