Certificate of Compliance 9045,Revision 2,for Model GE-1000
ML19331C622
Person / Time
Site: 07109045
Issue date: 08/01/1980
From: Macdonald C
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To:
Shared Package
ML19331C621 List:
References
NUDOCS 8008190188
Download: ML19331C622 (3)


Text

Ob e

Form NRC418 U.S. NUCLEAR REGULATORY COMMISSION CERTIFICATE OF COMPLIANCE 10 C R 71 For Radioactive Materials Packages 1.(a) Certifecate Number 1.(b) Revision No.

1.(c) Package Identification No.

1.(d) Pages No. 1.{e) Total No. Pages 9045 2

USA /9045/B( )

1 3

2. PREAMBLE 2.tal This certificate is issued to satisfy Sections 173.393a,173.394,173.395, and 173.396 of the Department of Transportation Hazardous Materials Regulations (49 CFR 170189 and 14 CFR 103) and Sections 146-19-10a and 146-19-100 of the Department of Transportation Dangerous Cargoes Regulations (46 CFR 146-149), as amended.

2.(b) 1he packaging and contents described in item s below, meets the safety standards set forth in Subpart C of Title 10, Code of Federal Regulations, Part 71 ** Packaging of Radioactive Materials for Transport and Transportation of Radioactive Material Under Certain Conditions."

2.fc)

This certificate does not relieve the consignor from compliance with any requirement of the regulations of the U.S. Department of Transportation or other applicable regulatory. agencies, including the government of any country through or into which the package will be transported.

3. This certificate is issued on the basis of a safety analysis report of the package design or application-3.lal Prepared by (Name and address):

3.(b)

Title and identification of report or application:

General Electric Company General Electric Company application dated l

P. O. Box 460 April 21, 1980, as supplemented.

Pleasanton, CA 94566 71-9045 3 (c) Docket No.

4 CONDITIONS This certificate is conditional upon the fulfilling of the requirements of Subpart O of 10 CFR 71, as applicable, and the conditions specified in item S below.

5. Descreation of Packaging and Authorized Contents. Model Number Fin.le Class. Other Conditions, and

References:

(a) Packaging (1) Model No.:

GE-1000 (2) Description Steel encased lead shielded shipping cask.

A double-walled steel cylinder protective jacket encloses the cask during transport.

It is bolted to a steel pellet.

The cask is closed by a lead-filled flanged plug fitted with a silicone rubber gasket and bolted closure.

The physical description is as follows:

Cask height,.in 28.5 Cask diameter, in 21.75 Cavity height, in 9.5 Cavity diameter, in 1.75 Lead shielding, in 8.75 Protective jacket height, in 38.25 Protective jacket width, in 33.75 Packaging weight, lbs 5,200 800819e I d.

Dage 2 - Certificate No. 9045 - Revision No. 2 - Docket No. 71-9045 (3) Drawings The packaging is constructed in accordance with the following General Electric Company Drawing Nos.:

161F478, Rev. 2 106D3879, Rev. 2 161F479, Rev. 2 10603880, Rev. 2 (b) Contents (1) Type and form of material (i) Byproduct material meeting special form requirements of 10 CFR 971.4(o); or (ii) Solid metal non-fissile irradiated metal hardware.

(?) Maximum quantity of material per package.

Radioactive decay heat not to exceed 250 watts.

6.

Shoring shall be provided to minimize movement of contents during accident conditions of transport.

7.

Package contents shall be delivered to a carrier dry.

8.

Prior to each shipment the silicon rubber lid gasket shall be inspection.

The silicone rubber gasket shall be replaced if inspection shows any defects or every twelve (12) months, whichever occurs first.

9.

The package authorized by this certificate is hereby approved for user under the general license provisions of 10 CFR 671.12(b).

10.

Expiration date:

July 31, 1985.

i

=

av 4,--

g

i fage 3 - Certificate No. 9045 - Revision No. 2 - Docket No. 71-9045 REFERENCES General Electric Company application dated April 21, 1980.

Supplements dated:

November 19 (Exhibit A), 1968; and February 20 and 27, 1969.

FOR THE U.S. NUCLEAR REGULATORY COMMISSION k

Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety AUG 011980 Date:

, - - -,,.