Text

'

,e o-t W' ?

THE CINCINNATI GAS & ELECTRIC COMPANY se

~

CINCINN ATO.QMIO 45201 E. A. SORG M ANN n......

May 29, 1980 QA-1302 U. S. Nuclear Regulatory Comission Region III 799 Roosevelt Road i

Glen Ellyn, Illinois 60137 Attention: Mr. J. G. Keppler, Director RE: WM. H. ZIMMER NUCLEAR POWER STATION - UNIT I REPORT ON 10CFR50.55(e) EVENT M-22, WELDS REJECTED UPON RADIOGRAPH REVIEW, DOCKET NO.

50-358, CONSTRUCTION PERMIT NO. CPPR-88, W.O. #57300-957, JOB E-5590 Gentlemen:

This is an interim report on a 10CFR50.55(e) event which was reported verbally to Mr. F. T. Daniels, Resident Inspector, on May 2,1980.

1 In October,1979. The Cincinnati Gas & Electric Conpany initiated a myiew of all radiograph packages of process piping welds at the Zimer project.

Initially, the review was only directed toward a^etection of documentation and technique deficiencies.

It was later expanded to include re-interpretation of the film.

At the time of the report to Mr. Daniels, the review program had been temporarily discontinued. Welds reviewed totaled 1565; of these 13 were judged to have questionable indications and one (1) was rejected on the basis of film density. Of these 14,13 were re-radiographed and six (6) were judged to be acceptable.

One (1) had been removed as a result of piping modifications.

The remaining seven (7) were the subject of further investigation. A sunnary of the present status of these seven welds is included as Attachment "A".

The review program has been resumed, and approximately 840 radiograph packages remain to be reviewed. We will submit a final report upon completion e

NN 91sy 8008)30 2 2 5

)

e s

l.

Mr. J. G. K2ppler. Director U. S. Nuclear Regulatory Comission Region III May 29,1980 - QA-1302 Page 2 of our review.

We trust that this letter will fulfill the reporting requirements of 10CFR50.55(e).

Very truly yours, THE CINCINNATI GAS & ELECTRIC COMPANY

,, ff f,,- _

E. A. BORGMANN SENIOR VICE PRESIDENT RLW:pa Enclosure

-- -. - E.

-n

/4 i

(.

ATTACHMENT "A" LETTER QA-1302 STATUS OF QUESTIONABLE PIPING WELDS e

Weld Identification Status WRK-825 Awaiting repair RI-77 Removed and replaced - Accepted RH-415 Ground and re-radiographed - Accepted VPK-281 Indication determined to be surface condition - Accepted WRK-72 Gound and re-radiographed - Accepted WR-ll3 Accepted on the basis of borescope examination of internal surface WD-389 Evaluation in progress 1

l l

I

.,..,.,,.w._

e

- - ~ -

  • = * *