ML19331B799

From kanterella
Jump to navigation Jump to search
Interim Deficiency Rept Re Welds Rejected Upon Radiographic Review.Seven of 1,565 Welds Were Judged to Have Questionable Indications & One Was Rejected on Basis of Film Density. Summary of Status of Seven Welds Encl
ML19331B799
Person / Time
Site: Zimmer
Issue date: 05/29/1980
From: Borgmann E
CINCINNATI GAS & ELECTRIC CO.
To:
Shared Package
ML19331B798 List:
References
QA-1302, NUDOCS 8008130225
Download: ML19331B799 (3)


Text

'

,e o- t THE CINCINNATI GAS & ELECTRIC COMPANY W' ?

se ~

CINCINN ATO.QMIO 45201 E. A. SORG M ANN

  • n...... -

May 29, 1980 QA-1302 U. S. Nuclear Regulatory Comission Region III 799 Roosevelt Road i Glen Ellyn, Illinois 60137  ;

l Attention: Mr. J. G. Keppler, Director RE: WM. H. ZIMMER NUCLEAR POWER STATION - UNIT I REPORT ON 10CFR50.55(e) EVENT M-22, WELDS REJECTED UPON RADIOGRAPH REVIEW, DOCKET NO.

50-358, CONSTRUCTION PERMIT NO. CPPR-88, W.O. #57300-957, JOB E-5590 Gentlemen:

l This is an interim report on a 10CFR50.55(e) event which was reported verbally to Mr. F. T. Daniels, Resident Inspector, on May 2,1980. 1 1

In October,1979. The Cincinnati Gas & Electric Conpany initiated a myiew of all radiograph packages of process piping welds at the Zimer project. Initially, the review was only directed toward a^etection of documentation and technique deficiencies. It was later expanded to include re-interpretation of the film.

At the time of the report to Mr. Daniels, the review program had been temporarily discontinued. Welds reviewed totaled 1565; of these 13 were judged to have questionable indications and one (1) was rejected on the basis of film density. Of these 14,13 were re-radiographed and six (6) were judged to be acceptable. One (1) had been removed as a result of piping modifications. The remaining seven (7) were the subject of further investigation. A sunnary of the present status of these seven welds is included as Attachment "A".

The review program has been resumed, and approximately 840 radiograph l packages remain to be reviewed. We will submit a final report upon completion l e

NN 91sy 8008)30 2 2 5

e s )

. l

. l. l Mr. J. G. K2ppler. Director  !

. - U. S. Nuclear Regulatory Comission '

Region III May 29,1980 - QA-1302 Page 2 of our review.

We trust that this letter will fulfill the reporting requirements of 10CFR50.55(e).

Very truly yours, THE CINCINNATI GAS & ELECTRIC COMPANY

,, ff f ,,- _

E. A. BORGMANN SENIOR VICE PRESIDENT RLW:pa Enclosure

-- - . - E. .- . . - -n .. - . . ,

/4 '

i

.,' (.

ATTACHMENT "A" LETTER QA-1302 STATUS OF QUESTIONABLE PIPING WELDS ,

e

> Weld Identification Status WRK-825 Awaiting repair RI-77 Removed and replaced - Accepted RH-415 Ground and re-radiographed - Accepted VPK-281 Indication determined to be surface condition - Accepted WRK-72 Gound and re-radiographed - Accepted WR-ll3 Accepted on the basis of borescope examination of internal surface WD-389 Evaluation in progress I

1 l

l I

l e - - ~ - * * = * *

.,..,.,,.w._