PM-79-899, Forwards Final Startup Testing Rept Covering Testing & Results of Fuel Loading Through Power Testing Up to 100% Power & Warranty Demonstration

From kanterella
(Redirected from ML19331B511)
Jump to navigation Jump to search
Forwards Final Startup Testing Rept Covering Testing & Results of Fuel Loading Through Power Testing Up to 100% Power & Warranty Demonstration
ML19331B511
Person / Time
Site: Hatch 
Issue date: 10/02/1979
From: Manry M
GEORGIA POWER CO.
To: James O'Reilly, Stello V
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II), NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
Shared Package
ML19331B512 List:
References
PM-79-899, NUDOCS 8008120372
Download: ML19331B511 (1)


Text

Gecrgia Power Cornsany Pest Olnen Gor 442 s

,w Bamicy.Georqu3 5 3 Telephort'Jld 3t3a./ /tlI 912$37 9444 L

Georgia Power Edwin t. Hatch Nuchar Plant the sotthctn ecctre sys:cm October 2,1979' PM-79-899 PLANT E. I. HATCH

~~

Hatch 2 Startup Test Report Mr. James P. O'Reilly Region II, USNRC Office of Inspection and Enforcement 230 Peachtree St. NW., Suite 1217 Atlanta, Georgia 30303 Mr. Victor Stello' c/o Distribution Services Branch, DDC, ADM U.S. Nuclear Regulatory Comission Washington, D.C.

20555 Office of Management Info, and Program Control U S. Nuclear Regulatory Commi.ssion

.NPIC Washington, D.C..

20555

Dear fir:

Please find enclosed the final submitted portion of the HNP-2 Startup Testing Report.

This portion of the Startup Testing Report ccvers the testing and results of fuel loading through pcwer testing up to 100*.' powar and the Warranty demnstration.

This submittal completes the startup testing report require-ments of the Technical Specifications.

l l

N 1.M. ;%*

runner n Plant Manager DAB /hh

'C N xc:

T. V. Greene C. T. Moore C. L. Coggin 5

D. A. Brock

/ }f l

L. T. Gucwa

/

File:'2M81 800812Oj/2' p

.