O
[v as%,%,
UNITED STATES NUCLEAR REGULATORY COMMISSION 3i
~^
REGION IV
- ! >*i;3 ett RYAN Pt.AZA DRIVE,SulTE 1000
,.g.
j ARLINGTON, TEXAS 76012 77A AIg vg
%,10...../
2 4 MAR '920 Docket No.
99900039/79-02 Rhine-Schelde-Verolme Zware Apparatenbouw b.v.
Attn: Mr. B. J. A. Sluis Managing Director Heijplaatstraat 4, P. O. Box 221 Rotterdam, THE NETamlNDS Gentlemen:
Thank you for your letter of February 19, 1980, in response to our letter dated Jann=ry 14, 1980. As a result of our review, we find that addition-al information on the following items in the Notice of Deviation is needed:
3.
Your response falls to provide any measures to prevent recurrence relative to the use of sizing calculations performed by another company, without documented evidence of RSV-A design review.
C.
Please inform us of what actions have been taken to identify the reasons for the error in sketch requirements and the nature of subsequent corrective actions.
Please provide this additional information within twenty (20) days in order that we may complete our review in a timely manner.
Sincerelyg
[C t-3.
l b
W Uldis Potapovs,(/b", Af Chief Vendor Inspection Branch o
8007310 Rb
-