ML19330A769

From kanterella
Jump to navigation Jump to search
Ack Receipt of Informing NRC of Steps Taken to Correct Deviation Noted in QA Program Insp Rept 99900216/80-01.Addl Info Requested Re Item H
ML19330A769
Person / Time
Issue date: 06/17/1980
From: Potapovs U
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Katz L
TUBECO, INC.
Shared Package
ML19330A762 List:
References
REF-QA-99900216 NUDOCS 8007290378
Download: ML19330A769 (1)


Text

,.

+

?%

O

.pA "8c UNITED STATES o,':,

c NUCLEAR REGULATORY COMMISSION f

+- 1 REGIONIV 2 3 ' '*' I E

611 RY AN PLAZA ORIVE, SulTE 1000 3.,

'?,

ARLINGTCN, TEXAS 76012

%...'.. f 17 JUN 1c80 Docket No. 99900216/80-01 Tubeco, Inc.

Attn:

Mr. L. Katz Director, Quality Assurance 123 Varick Avenue Brooklyn, NY 11237

~

Gentlemen:

Thank you for your letter of May 8,1980, in response to our letter dated April 18, 1980, with an enclosure.

As a result of our review, we find that additional infornation is needed on the following item in the Notice of Deviation.

Item H Your response fails to provide any measures taken to preclude recurrence of addit 1cnal failures to implement ccanitted corrective actions.

Please provide this additional infonnation within wenty (20) days in order that we may complete our review in a timely manner.

Sincerely, W p.

er U1 is Potacovs, Chief Vendor Inspection Branch 800729037F'

.-