Text

.

a m.

Farm NRC418 U.S. NUCLE AR REGUL/.TCRY COMMISSION CERTIFICATE OF COMPLIANCE to C R 71 For Radioactive Materials Pactages 1.lt) Cwtificate Nummer 1.(b) Revision No.

1.(c) Package identification No.

1.(d) Pages No. 1.(e) Total No. Pages onst 9

tic A /once /Af T 1

7

2. PREAMBLE 3.fa)

This ce tificate is issued to satisfy Sections 173293a.173.394,173.395. and 173.396 of the Department of Transportation Hazareous Materials Regulations (49 CFR 17o.189 and 14 CFR 103) and sections 146-19-1Ca and 146-19-100 of the Department of Transoortation Dangerous Cargoes Regulations (46 CF R 146-149). as amended.

2.15)

The packagiris and comenu described in hem s below, rneets the safety standares set forth in subpart C of "ritle 10, Code of

, Federal Regulatio is. Part 71, ** Packaging of Radioactive Materials for Transport and Transportation of Radioactive Materia! Unser Certain Conditions."

y,.

,a p *..~..

-=_-..

. =:.

~

T.(c)

This certificate does not relieve the consignor from compliana with any reovirement of the regulations of the U.S. Department of Transportation or other applicanie regulatory agencies, including the governme'it of any country through or into whien the package will be transported.

3. This certificate is issued on the bas:s of a safety analysis report of the package design or application-

~

3.la)

Prepared by (Name and address):

3.tb)

Title and identification of report or application:

Technical Operations, Inc.

Technical Operations, Inc. application dated Northwest Industrial Park June 16, 1980.

Burlington, MA 01803 3.fc)

Doe et so.

71-9053

  • 4.

CDNDITIONS 4

This certificate is conditional upon the fulfilling of the recuirements of Subpart D of 10 CFR 71, as acc'icaole, and the concitions specified

_in item 5 besoa.

L. Description of Packaging anc Autnorizec Contents, Mocel Numoer. Fissde Class, C-ner Conditions, and

References:

(a) Packagiag (1) Model No.:

683 (2) Description A radiographic exposure device contained within a protective overpack.

The overpack is an 18 gage, MS27683 steel drum with a bolted and seal wire clamp closure ring.

The drum is filled with molded rubberized

-hair to maintain a snug fit.

Overall dimensions are 19.5" diameter x 15" high.

The radiograohic exposure device consists of an 11 gage carbon steel shell, depleted uranium shielding, zircalloy "S" tube, polyurethane filler material, source shipping plug and lock assembly.

Gross weight of the package is approximately 89 lbs.

(3) Drawings The packaging is constructed in accordance with the following Technical Operations, Inc. Drawing Nos.:

C68302;C68302-1, ?, 4; C68303; B68303-1, Sh. 2; B68302-9, B68307-1; A68307; A68308-1C; A86302-8; A68311; A68309-9.

i l

I

\\

80 0n 2 8076

3 o

.s Page 2 - Certificate No. 9053 --Revision No. 2 -~ Docket No. 71-9053 5.

'(b) Contents I

(1) Type and form of material Iridium-192 as sealed sources that meet the requirements of special i

form as defined in 571.4(o) of 10 CFR Part 71.

(2) Maximum quantity of material per package 120 curies 6.

Source assemblies for use in this packaging are limited to those assemblies as identified in Technical Operations, Inc. Drawings Nos. A68309, and C68310.

7.

. Nameplate shall be fabricated of materials capable of resisting the fire test of 10 CFR Part 71 and maintaining their legibility.

8.

The packaging authorized by this certificate is hereby approved for use under the general provisions of 10 CFR s71.12(b).

9.

Expiration date:

July 31, 1985.

REFERENCE Technical Operations, Inc. application dated June 16, 1990.

FOR THE U.S. NUCLEAR REGULATORY COMMISSION

~

Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety JUL 1413e0 Datec.:

/

L-