eb THE CINCINNATI GAS & ELECTRIC COMPANY as -

CINCINNATI OHIO 45201 July 8, 1980

'$73.72."[""

United States Nuclear Regulatory Commission Office of Inspection and Enforcement Region III 799 Roosevelt Road Glen Ellyn, Ill. 60137 Attn:

Mr. James G. Keppler Regional Director Re:

WM. H.

ZIMMER NUCLEAR POWER STATION - UNIT 1 IE BULLETIN 79-03A, DOCKET 50-358 W.O.

57300, JOB E-5590 Gentlemen:

In response to IE Bulletin 79-03A concerning longitudinal weld defects in ASME SA-312, type 304 stainless steel pipe, please be advised that all SA-312 or A-312, type 300 series piping fur-nished to the Zimmer Station is seamless.

Seamless pipe is furnished up to size 12".

Sizes 14 through 24" are specified to A-358, which is double welded with filler metal.

SA-312 or A-312, type 300 series fusion welded pipe is not used in the Zimmer Station piping systems.

Very truly yours, THE CINCINNATI GAS 6 ELECTRIC COMPANY hp-E. A. Borgmann Senior Vice President DJF:PLH/jb cc: