O Firm NRC418 U.S. NUCLE AR e<EGULAToRY CoMMISSloN U
10 CFR 71 CERTIFICATE OF COMPLIANCE For Radioactive Materials Packages 1.(a) Certificate Number 1.(b) Revision No.
1.(c) Package Identification No.
1.(d) Pages No. 1.(e) Total No. Pages 9AA7 9
IKA/9AA7/R( )
1
?
- 2. PRE AMBLE 2.(a)
This certificate is is6ued to satisfy Sections 173.393a.173.394,173.395. and 173.396 of the Department of Transportation Hazardous Materials Regulations (49 CFR 170-189 and 14 CFR 103) and Sections 146-19-10s and 146-19-100 of the Department of Transportation Dangerous Cargoes Regulations (46 CFR 146-149), as amended.
2.(b)
The packaging and contents described in item 5 below, meets the safety standards set forth in Subpart C of Title 10. Code of Federal Regulations. Part 71," Packaging of Radioactive Materials for Transport and Transportation of Radioactive Materiet Under Certain Conditions.**
2.fc)
This certificate does not relieve the consignor from compliance with any requirement of the regulations of the U.S. Department of Transoortation or other applicable regulatory agencies, including the government of any country through or into which the package will be transported.
- 3. This certificate is issued on the basis of a safety analysis report of the package design or application-3.(a)
Prepared by (Name and address):
3.(b)
Title and identification of report or' application:
Teledyne Energy Systems Isotopes, Inc. application dated August 10, 110 West Timonium Road 1971, as supplemented.
Timonium, MD 21093 3.(c)
Docket No.
71-5862 4 CONDITIONS This certificate is conditional upon the fulfilling of the requirements of Subpart O of 10 CFR 71, as applicable and the conditions specified in item 5 below.
- 5. Description of Packaging and Authorized Contents. Model Numoer, Fissile Class, Other Conditions, and References; (a) Packaging (1) Model No.:
Sentinel-100F (2) Description The package, a thermoelectric generator, is 45.5 inches in height with a base diameter of 24.5 inches (excluding mounting pads), and weighs approx-imately 2,600 pounds. The components include a Tungsten biological shield (10.705" x 13.837" 00) which is within the aluminum (6061) outer protective housing.
Four 6061-T6 mounting pads at the base of the aluminum housing provide the shipping pallet attachment points.
i (3) Drawings l
The packaging is constructed in accordance with the following Isotopes, l
Inc. Drawing Nos.:
1 010F10000 Sheets 1-3 (Rev. A), Generator Assembly Sentinel 100F 010-20000 Fuel Capsule Assembly l
010-70003 Shield Body l
010-70004 Shield Plug L
001-90064 Sheets 1-2, Shipping Crate Sentinel RTG 001-90039 Sheets 1-4, Pallet Assembly i
81107170 k
A e
Page 2 - Certificate No. 5862 - Revision Ne. 2 - Docket No. 71-5862 5.
(b) Contents (1) Type and form of material Strontium 90 titanate doubly encapsulated in a stainless steel liner and Haste 11oy or Uniloy HC capsule which meet the requirements of special form as defined in 10 CFR 671.4(o).
(2) ~ Maximum quantity of material per package 370,000 Curies.
6.
The package authori:ed by this certificate is hereby approved for use under the general license provisions of 10 CFR $71.12(b).
7.
Expiration date:
July 31, 1985.
REFERENCES Isotopes, Inc., application dated August 10, 1971.
Supplements dated:
September 24, October 22, November 30, and December 20, 1971; and January 19, 1972.
sh THE U.S. NUCLEAR REGULATORY COMMISSION s
Cfarles E. MacDonald, Chie b
Transportation Certification Branch i
Division of Fuel Cycle and Material Safety JUL 0 9 G80 Date: