CONSUMERS POWER COMPANY Report #5, March 29, 1974 Pursuant' to Conditions 2.F.B. and 2.F.C. of Construction Permits CPPR-81 p
and CPPR-82.
Covering the period April 1 - June 30,1974.
A.
Construction work to be performed during the period April 1 - June 30,1974.
APRIL 1974 Containment #2 1.
Concrete placement -6f' containment base slab.
2.
Erect and begin welding first lift of liner plate.
3.
Begin placement of post tensioning embedded metal.
4.
Begin placement of reinforcing steel required for exterior wall concrete.
5.
Continue prefabrication of second lift of liner plate.
Containment #1 1.
Complete prefabrication and installation of #18 base slab
(.
reinforcing steel (bottom mat).
't.,
Continue installation of the #18 base slab reinforcing steel (top mr.t).
3.
Begin prefabrication of the primary and secondary thickened.
liner plate.
Turbine Building #2
'1.
Complete the concrete placement of the condensate area duct banks.
2.
Install 96" and 72" circulating water pipe in the condensate sump area.
3.
Complete the concrete placement of the condensate sump to el. 606' - 3".
4.
Complete excavation required for the turbine pedestal.
M m
8 0 0 6 30 0 7 Jg
s P2ga 2 3
Auxiliary Building t-.
t 1.
Erect structural steel in the south half.
Q O'
2.
Concrete placement of the south wall pilaster.
3.
Concrete placement of the interior walls in the south half of the auxiliary building from el. 568' - 0."
to el. 584' - 0".
MAY 1974 Containment #2
- 1.. Continue the velding of the first lif t of liner plate.
2.
Continue installation of the post tensioning embedded metal.
3.
Begin concrete placement of the e=terior wall.
4.
Continue prefabrication of the second lif t of liner plate.
5.
Continue welding the floor liner plate.
Containment #1 i
1.
Continue installation of the top mat of the base slab reinforcing steel.
2.
Continue prefabrication of primary and secondary shield wall thickened liner plate.
Turbine #2 j
1.
Begin installation of the turbine pedestal formwork and reinforcing steel.
Auxiliary Building 1.
Install embedded drain piping in the slab at el. 584' - 0" (south half).
2.
Concrete placement of the south half of the slab at el. 584' - 0".
1
('_
e
- e
,,e p
4 O
,e Page 3 3.
Concrete placement of the interior walls in the north half to el. 584' - 0".
4.
Erect structural steel in the north half at el. 584' - 0".
r.
'y.
5.
Set 96" pipeway from Auxiliary Building to the Turbine Building.
JUNE 1974 Containment #2 1.
Complete the welding of the first lif t of liner plate.
2.
Begin erection of the second lif t of liner plate.
3.
Continue the concrete placement of the exterior wall.
4.
Continue welding the floor liner plate.
Containment #1 1.
Continue installation of the base slab reinforcing and thickened liner plate.
Turbine #2 1.
Concrete placement of the slab at el. 584' - 0" in the north side.
2.
Erect structural steel for the slab at el. 599' - C" in the south half.
3.
Install embedded drain piping in the slab at el. 599' - 0" in the south half.
4.
Concrete placement of the slab at el. 599' - 0" in the south half.
B.
Supervisors and engineers of the Applicant and Architect-Engineer with quality-related duties who are expected to be on site during the period April 1 - June 30, 1974.
(t_
I I
.~
\\
Pcg2 4 1.
Consumers Power Company - No change from last report.
2.
Bechtel Power Corporation
- r'
\\
\\
The following Bechtel Power Corporation supervisors and engineers
)
-4 Sp are expected to be on site in addition to the personnel with quality-related duties identified in previous reports.
a.
Quality Control J. H. Tice Acting Assistant Project Field Quality Control Engineer and Lead QC Mechanical Enginecr R. E. Uhouse Assistant QC Engfneer (Civil)
G. L. Gillie Assistant QC Engineer (Civil)
D. C. Thompson Acting QC Lead Electrical Engineer R. H. Moray QC Receiving Engineer A. L. Boulden QC Lead Welding Engineer W. O. Howe QC Welding Engineer J. F. Gibson QC Welding Engineer f
b.
Quality Assurance
- 1) Located at the Site W. J. Key Quality Assurance Engineer
- 2) Located in Home Office and on site and involved with this project only fer special audits.
J. D. Laurie QA Management Audit Team L. J. Grant QA Management Audit Team J. (NMI) Milanalin QA Management Audit Team R. E. Allen QA Management Audit Team
~
V. E. Matson QA Management Audit Team B. D. Hackney QA Management Audit Team R. C. Stanley QA Management Audit Team O\\
- s_
1 Pagn 5 3.
U. S. Testing personnel with quality related duties on site only to replace Consumers Power Company Quality Assurance C
personnel during the time the latter are off site to attend
. 'g i'
training sessions.
E. J. Zadina C. A. Sheridan J. B. McAvoy A. J. Walcutt i
C.- Quality assurance qualifications of supervisors and engineers with
. site-related duties during the period April 1 - June 30, 1974:
1 Statements of qualifications of all the individuals listed in "B" above are attached hereto.
D.
Changes 1.
Consumers Power Company - No change from last report.
2.
Bechtel Power Corporation On March 11, 1974, W. F. Holub replaced J. I. Dotson as Project
~
Quality Assurance Engineer (located in the Ann Arbor office).
Mr. Dotson is now assigned to the staff of the Ann Arbor Quality Assurance Supervisor.
Additions to or deletions from the list of supervisors and engineers with quality-related duties who are to be on site during the report period will be noted on the next report together with a description of their quality assurance qualifications. All of the individuals named in "B" above had site-related duties during the period January 1 - March 31,1974.
l
~
8 l
- ~ ~
JAMES H. TICE LEAD PIPING AND MECHANICAL QC ENGINEER 4'
Mr. Tice's education encompasses, high school and a number of job related courses. Mr. Tice has most recently been employed as the Lead Piping and Mechanical Quality Control Engineer at Peach' Bottom Nuclear Generating Station. There he assited the P.F.Q.C.E.
in the supervision of inspection and documentation required by the
. specification's and procedures.
Previously, he was an inspector of const'ruction at the John F. Kennedy Space Center; the last 5 years at the Space Center as supervisor of Quality Control.
Mr.Ticehas(15)fifteenyearsinconstrudtionQualityControl.
t B
J
-.o e
f g
e Q
'L 4
e
l y.
Robert E. Uhouse
.Bechtel Power Corporation Quality Control Engineer Mr Uhouse is a High School Graduate with'an Associate Degree in Civil Engineering Technology from Alfred State College, Alfred, New York.
.Mr. Uhouse joined Bechtel Power Corporation in July of 1973 as a draftsnan in the Civil and Plant Design Section of the Ann Arbor Office, transferring to the Quality Centrol Section at the Midland Site in February 197h.
Since arriving at the Midland Site, Mr.
huse has received extensive traimng in Cadweld Inspection, Pro-tective Coatings Inspection, and Review of Reinforcing Steel IE11 Certs and Test Reports.
Mr. Uhouse has also received training in the Inspection Planning Concept in use at the Midland Site.
Prior to joining Bectel, Mr. Uhouse served two years in the United States Marine Corps., verking as a construction laborer, and mechanic.
d
\\
Q q
9 e
g,.
~
{
'g N
Gregory L. Gillie Bechtel Power Corporation Quality Control Engineer Mr. G'illie joined Bechtel Power Corporation on January 9,197h.
He is a High School Graduate with three years of college and an As-sociate Degree in Applied Science.
Prior to joining Bechtel, It. Gillie was enployed in various aspects of, the Autonotive Field, including Repairnan, Service, Writer, Trouble Shooter and Inspection of Engine Block Castings.
Since joining Bechtel Power Corporation, It. Gillie has received intensive training sessions and on the job training in Cadweld In-spection.
Mr. Gillie also attended a three day seminar on Pro-tectivb Coatings presented by Ib. Een Tator of Keane Tator Asso-oiates and received on the job train'ng in Protective Coatings at the Midland Job Site.
j 9
e
)
~
y
Douglas C. Tho.. son.
Lead Electrical Quality Control Engine:r Becht:1 Pow;r Corp.
Mr.. Thompson is a graduate from Coyne Electrical and Technical School with a Certificate in Electrical Power and National Elec-('
trical Code, Lowry Technical Training Center,. USAF, with a Cert-ificate in Electronics and Radar.
He has 6 years experience in g
Quality Control with the United States Air Force and Bechtel Power Corp.
Mr. Thompson was recently assigned the duties as Assistant and now Lead Electrical Quality Control Engineer at the Peach Bottom Naclear Power Generation Station and Midland Project, Job #7220.
At Peach Bottom he assisted the LEQCE in supervision, documentation and inspection of the Electrical Group activities and equipment in-stalation. Mr. Thompson, as a Field Engineer at the Pilgrin Nuclear Power Generation Station, had the duties of installation and check-out of electric components for ESS and RPS, and Quality Control per the Field Inspection Manual.
G O
~
. I O
e 0
s r
e
. Me G
l
~ e it 1 %.
s
- me e=
4 g
per
u Robert Alan Moray Quality Control Receiving -Inspector Bechtel Power Corporation
~
p.
Eiucation:
B. A. degree in Basiness Mministration from Michigan
- g State Unive'rsity s
Military:
S' eparated from Ar:y with rank of Sergeant in the Combat Engineers
-Work:
Three y5ars work for Litisey & Co.,now the mechanical division of J. A. Jonesiat the Donald C. Cook Nuclear Power Plant.
~
Positions held with Linsey include Fittings Warehouse Contro1can,
., Yalve Etpeditor, Asst. Materials Control Supervisor, Pre--
operational Engineer, Field Engineer (Turbine Bldg) and Q.A. Engineer.
~
I t
l O
e I
a e
e.
G s
e
. 1 m
6 e
Q O
8 e
P x
e
~..~
A. L. Boulden
(
Lead Quality Control Field Velding Engineer Bechtel Power Corporation x.
,F,,..
s Mr. Boulden is a high school graduate with some. college courses.
He has 16 years welding experience in various processes and metals.
He also had 6 years supervision experience with craft personnel dealing primarily with welding and IDE related work.
Mr. Boulden has most r'ecently been employed as a Lead Quality Control Field Velding Engineer at the Peach Bottom Nuclear Power Plant in hita, Pennsylvania.
There he directed the activities of the Quality Control Velding Engineers in their daily activities for inspection, surveillance and documentation of all the field welding and IDE activ-t s'
ities.
He has had experience in Liquid Penetrant, Ma6netic Particle, 1
and Radiograph interpetation, and is presently qualified as a Level II I
for Bechtel on Liquid Penetrant.
e 9
s._
',, z.
Vynn 0, Howe Senior Pield Quality Control Welding Engineer Bechtel Power Corporation.
(~
Mr.HoweattendedColoradoA&MCollege(nowColoradoStateCollege) l as an Inductrial Arts Major, Mechanical Engineering Minor.
He is a
- (,memberoftheAmericanSocietyforQualityControlandhasmorethan-twenty years experience in the field of Metallurgical Joining, most of which has been highly quality oriented.
He has more than three years experience in the field of Nuclear Power Generation.
Mr. Howe was most recently employed as Principal Engineer'in the Engineering N=ce=ent and Quality Assurance Unit of the Maritime re-actors Section of the Nuclear Power Generation Division of the Babcock and Wilcox Company. He was responsible for the develope =ent and in-plementation of Configuration Management and Quality Assurance Programs and related procedures and documentation.
Previously he developed and implemented a Quality Assurance and Control Program and the Manual which obtained the ASME "N" and "NPT" stamps and i
the State of Michigan Installers License for Liversey and Company, Inc.,
a subsidiary of the J. A. Jones Construction Co=pany. Prior to this, l
Mr. Howe was employed for nearly fifteen years by the Boeing Company where he achieved the status of Research Engineer in the Metallurgical Joining Department of the Materials Technology Unit.
His duties in-volved: Design Consultation relative to aH welding, bracing, soldering,
(
and metallurgical bonding activities performed within the company or by suppliers to the co=pany, Development of Design A11ovables, Development of Process Control Specifications, Development of Acceptance Criteria Standards, Liaison activities between design and production personnel both within the company and with suppliers to the company.
His most recent contribution to the Boeing Company was the development and implementation of an "in-place welded" hydraulic line joint for the 7h7 afrplane, the only commercial aircraft in the world using this weight saving and leak free connection.
1 j
1 i
4y
\\
..,i;
?
~~
J. F. Gibson
~
Quality Control Engineer e
Beehtel Power Corporation y.:.;
~
Mr. Gibson graduated from the University of San Francisco with a B.S.
in Business Mministration, and has 35 years velding experience.
-.i Mr. Gibson has most recently been employed as Assistant Lead Quality Control Field Welding Engineer at the Peach Bottom Nuclear Power Plant in Delta Fennsylvania.
There he assisted in directing the activities of the~ Quality Control Welding Engineers in their daily activities for inspection, sur-veillance and documentation of all the field velding and IGE activities.
He has had experience in Liquid Penetrant, Magnetic Particle, and Radiograph Interpretation, and is presently qualified as a Level II for Bechtel on Liquid Penetrant.
O Q
g 4
h
- 'a
- em ee G
~
e f
.5
,. L; s
-e..
~~
p
\\
e l(-
January 29,1974 Resume of' William J. Key:
~
Mr. Key joined Bechtel Corporation January 21, 1974 as a Senior Quality Assurance Engineer in the Power Division.
He has been assigned to the Midland Project.
After a twenty-two (22) year naval career, Mr. Key spent two (2) years as a non-destructive testing technician at Westinghouse Elcotric Marine Division.
Thiswasfollouedbyfive(5)yearsasamechanicaland non-destructive testing inspector with the state of California Department of Water Resources.
Mr. Key is a member of the American Society of Non-Destructive Testing, and has been qualified as a level II inspector in radiography, ultrasonic, ma6netic partical
(
and liquid penetrant methods of inspection.
~
e O
e G
S
==m O
e s
c O
e o
.v-Yanuary. 14,.1974 p
'c Name Position Title Qualification *s J
D. Laurie Senior Quality Mr. Laurie joined Bechtel in Assurance Engineer December,1972 as a Senior Quality Assurance Engineer /
Audit Team Chairman.
He attended Ball State University and Indiana Institute of Tech-nology, majoring in Engineering.
His work experience includes fourteen ti 1) years as an engi-neer. Since 1967 he has been j
involved in NSSS pressure vessel manufacturing and nuclear power plant construction as a Material O
and Welding Engiceer, Quality V
Control Engineer and Quality
(*
Assurance Engineer.
0 e
e e
g e
e y
e O
4 O
3 4
e g
9 e
e e
6 g
9 9
g o
O e
a e
(
O e
o e
O O
Jan'ary 17, 197-2.
. ;f..-G,.
(".
~
Name ~
' ' *> Position Title Qualifications s
o
~
(
L. J. Grant Senior Quality Assurance Mr. Grant joined hts
- " Engineer
.in January,1973 as a Senior Quality Assuranci h-Engineer at the San Fram
~
cisco office. He was asd signed to the Limerick.
Nu~ clear Plant Site in June, 1973.
.p
.,4*
He is a graduate Civil
~
sional Registry in Cal-Engineer, with Profes-
.Y ifornia and Colorado.
3 His work experience in-cludes eleven (11) years
' r '.
as an engineer. Since 1963 he has been involveg in design and constructic O
engineer ag of num.
e.
-m -
g r.t. :
(
.:7.
plants, dams and p r(
plants
~;.r
.c.
1
. s..
~.
- 1...
.e-
..t.
.. %,.j g,,
a.
. 1.. ;
..i
- u
=.
. : ~.. &.,
g.
a
.t.
t.
i g
t O '.
O q..
e e
g
=
- p.,
i
.=
- s...
.r
. January 18, 1974
?
(*.
Name Qualifications J. Milandin Joined Bechtel as Supervisor of QA Management Auditing October,1973.
s.
[
o BSEE Tulane University 1951. Westinghouse Bettis Reactor Engineering and Shielding De-sign Schools and Nuclear Engineering Short Coure
~at.UC Berkeley 1957.
I.
Previous experience: 18 years with Ingalls Ship-building Nuclear Submarine Program in the Nucle >
' Power Organization as Nuclear Production Super intendent (2 years), Test Engineer (2 years) and
~
Director Nuclear Quality Assurance (14 years).
(
- s
-.s
.s.
+
c A
g g
\\
q_
g
._ w
Jcnu'.ry 10, 1974'
,.f.* '
. A.,
2.. -
Resume of n.
ROY E. ALLEN
(
t
. ::,y.
6 Mr. Allen joined Bechtel in November 1971, as a Senior
- s..
Quality Assurance Engineer at the FFTF site in Richland, a.:
Washington. He was reassigned to the Arkansas Nuclear
{Jy.;,- j, One plant site at Russellville, Arkansas in April 1972. In
.. ;p. ;
August 1973 he was moved to San Francisco as Project
. f p'1 Quality Assurance Engineer for'the Boardman Nuclear
[j.
Project.
- t. i.. n. -
Prior to coming with Bechtel, Mr. Allen held the positions
'c of Inspection Supervisor in the aircraft industry, Quality
'f Control Supervisor for Martin Marietta Corp. involved in construction of Titan I Missile Sites, and Quality Control
,- T.
Reliability Engineer for Catalytic-Do'.v at the Kennady Space
.Cente r.
. gj. c,.
.. r..
.S Mr. Allen has completed numerous college level courses
(
in electronics and the NASA School of Quality and Reliability As surance, His experience encompasses approximately 18
. years experience in quality and reliability.
A...:j ;,
.i.
g_
m.
e l
~-
O m ee
-e+
= ao m
y
(
e 8
- e. - -
e.
vuuunrv, 71we fy RESUME OF l
Verr,on E. Matson p
.0, ~
Mr. Matson joined Bechtel Power and Industrial Division in December
~
, of 1971 as Lead Welding Engineer for the Centralia, Washington project,
, responsible for all welding and Nondestructive Examinations'. In August of 1972, he transferred to the San Francisco Home Office as a Senior Welding Engineer for M,F&QCS and presently his duties consist of special assignments by the Field Welding Services Group, and acting as a member of the Q. A. Nucicar Audit Team for the majority of Bechtel's Nuclear
.proje cts.
Mr. Matson was previously employed by the Ralph M. Parsons Company as a Field Welding Engineer.
Mr. Matson attended Concordia College from 1954 through 1956, majoring in Business Administration and received specialized training courses in Nondestructive Testing. H;. is currently a Level II in Radiography, Liquid Penetrant, etc. and is in the process of being appointed to Level III.
O
~
g e-e
-e*
g
- e O
(,
g e
e M
', RESUME OF B. D..fACKNEY.
15 Janunry 1974 p.
Mr. Hackney joined Bechtel in ctober,1973, as ah Engineering Specialist in the Materials Fabrication and Quality Control Services Department and
/~,
is presently assigned as Engineering Supe.rvisor of the Fabrication and Qualit'y Control Services Section. Primary responsibiliti6s include:
'p 1.
MF&QCS audits of conventional and nuclear power plant-sites.
2.
Prepare and maintain Bechtel QC Manuals.
3.
Perform andlysis of site related failures.
4.
Participate in ASME Code activities ~ and maintain Bechtel's position before the ASME and AEC in MF&QCS area of interest.
Positions held by Mr. Hackney prior to joining Bechtel include welder.
Welding Engineer, Materials Engineer, Manager of Fabrication Engineering and QA and Manager of Engineering spanning a period of 15 years in the a
Nuclear Industry.
Mr. Hackney graduated from San Jose State College in 1962 with a Bachelor of Science Degree in Materials Engineering.
1 O
~
O' -
t G
e
Re suma cf R, t Stanby J
.sary 10,1974 5
~~
Mr. Stanley joined Bechtcl in March 1972 as'a Senior Metallurgical 3.,
Engin'eer in the Materials, Fabrication and Quality Control Services Department. His assigments in this department have included:
r
.(1) Member of Audit Team for ASME Nuclear Components at audits of Bechtel nuclear constructien sites.
(Sixteen such audits through December 1973).
(2) Audit of supplier's plants.
(3) Failure analysis of power plant equipment.
(4) Assist suppliers to resolve manufacturing problems.
(5) Review of supplier's welding and manufacturing procedures for compliance with Code and Bechtel requirements.
Positions held by Mr. Stanley prior to joining Bechtel include Supervisor of Metallurgical Engineering, Supervisor of Manufacturing Engineering, Reseach Engineer, and Manufacturing Engineer, in the industrial equip-ment, acrospace, and automotive indu stries.
'Mr. Stanicy graduated from Michigan Technological University in 1952 with a Bachelor of Science degree in Metallurgical Engineering.
~
RCS/imh '
~ ~
~ ~*.
e n m
L.
t e
UN ID STATES TESTING COMPAfi INC.
PROFESSIONAL RECORD b
ZADINA, EGON J.
h
-Quality Assurance Project Supervisor ACADEMIC TRAINING 1955 City College of New York BME 1956 George Washington University Courses in Business Administratioth 1960 City College of New York MME - Nuclear Engr.
M.1jor Various short courses in Engineering, Quality Assurance, Statistical Quality Control and Reliability EMPLOYMENT RECORD
. Dates
. Company
_ Position 1973 United States Testing Company QualityAssuranceh Project Supervisor 1970-1973 American Electric Power Co.
Q.A. Engineer
'1965-1970 George G. Sharp Inc.
Prcject Engineer 1963-1965 New York Naval Shipyard Asst. Q.A. Manager 1955-1963 New York Naval Shipyard Project Engineer PROFESSIONAL EXPERIENCE U.S. Testing
. Developed and assisted in the implementation of Q. A.
- Program for F.R. Harris Inc.; designers of the Atlantic 3enerating Station breakwater and mooring system.
Served as Operations Q.A. advisor to Public Service
. Electric & Gas Co. (N.J.) Manager of Nuclear Operations.
g
- t s
v 7,/.;
s Consultant to Baltimore ' Gas and Electric for Calvert Cliffs Nuclear Power Station Operations Q.A. and Manager of U.S. Testing field group which serves as lll the initial Operations Q.C.._ staff for,Calvert Cliffs.
f' Developed structural materials testing Q. A. Program
.for U.S. Testing's services to Bechtel Corp. on Midland 4,4 :
and Susquehanna Nuclear Power Plants.
i On-site testing programs involve reinforcing rod.and rod splice testing, concrete testing and soil testing.
American Electric Power Served as assistant to the Manager of Q.A.
Developed, implemented and audited various portions of the design, procurement and construction phase Q.A. Programs for this utility's first nuclear power plant.
Typteal construction phase audits were concrete, reinforced rod, piping, and containment liner.
Initiated, developed and implemented the D.C. Cook Nuclear Power Plant Operations Q.A. Program.
George G.
Sharp Inc.
Engaged in the preliminary and centract design of commercial and naval ship power plants systems.
Performed..u: eering studies for power plants.
Super-vised mec' anical detail design and procurement of piping systems for commercial special cargo ships.
\\
Assigned to Nav Sec Washington D.C. for 6 months.
New York Naval Shipyafd Developed, implemented and executed shipyard wide Q.C.
and Q.A. program for the design, construction and testing of naval ships.
Supervised detail design and procurement of power plant auxiliary systems for three multi-shaft ships.
Engaged
.in performance testing of power plants.
Supervised design and testing of prototype piping systems, specified welding requirements.
Served as cagnizant engineer for
. turbine, pumps and regulating valves.,
Engaged in the preliminary design of guided missile installation and handling systems at Nav Sec Washington D.C. for one year.
MEMBER:
American Society of Quality Control AUTHOR:
Electrical World Magazine Article Entitled h
i "What 0. A. Means to Utilities" Sept. 1973.
('
LICENSE:
Profess.ional Engineer, New York State, 1960 l
P'
- / 1 UNI D STATES TESTING COMPAN'
'N C, a
1ROFESSIONAL RECORD SHERIDAN, ClfARLES A.
c Quality Assurance Engineer
[ ACADEMIC TRAINING:
Cornell University - Industrial Relations Arbitration Ru'tgers University - Grievance Handling Rockland Community College - Management Skills,
. Supervisory Skills in Modern Management Administration of Human Resources
}lMPLOYMENT RECORD:
Dates Company Position
~
1972 - Present United States Testing Co., Inc.
Quality Assurad Engineer 1969 - 1972 Phelps Dodge Cable and Wire Quality Assuraq Superintendent 1967 - 1969 Wilcox & Gibbs Company Superviso Field Engineeri
,(
~
, 1964 - 1967 Wilcox & Gibbs Company Technical Suped visor 1955 - 1964 Wilcox & Gibbs Company
' Manufacturing Supervisor
.~ PROFESSIONAL EXPERIENCE:
United States Testing Co.,
Inc.
Mr. Sheridan specializes in quality assurance system evaluation and fabrication engineering.
His respon-sibilities include contractor quality control and
. assurance surveillance, evaluation of materials, welding and fabrication applications at vendor Facilities and Nuclear Power Plant Construction Sites.
L l
e
v o'
,~' a Phelps Dodge Cable and Wire Manufacture of high voltage power cable.
Mr. Sheridan's duties as O.A. Superintendent included supervision and responsibility for material inspection, final testing, customers representatives and certified test reports.
Wilcox & Gibbs Company Supervisor of field engineering, responsibilities included equipment design development and field testing of new and improved automatic machinery using mechanical hydraulic and electrical systems, trouble shooting and evaluation of customers'.. complaints.
Supervised scheduling *, production, quality control, cost control of high value, close tolerance components.
Responsible to vice president of manufacturing.
Supervised 45 men. in manufacturing, heat treating, welding, brazing, hand finishing, tumbling, inspection, milling, turret lathe, drilling, precision grinding, assembly, punchpress, painting, tool making.
PROFESSIONAL AFFILIATION Chamber of Commerce, Nyack,' N.Y.
Industrial Management Club of Rockland County e
4 m
oem b
o 4
O h
9 e
= we
==*
.e t-e
M o ',. '
UNI'
) STATES TESTING COMPAN" INC.
- o PROFESSIONAL RECORD
/.
N *
"~MC AVOY, JOHN B.
~
~
Quality Assurance Engineer ACADEMIC TRAINING High School Graduate J
Two Years Rutgers University St. Peter's University -
Two Years-B.S.
in Biology Chemistry -Minor Special Courses - Statistical Quality Control, Inspection & Testing of Materials, Safety Coursos (2 ' years) and Advanced Purchasing Techniques.
ll>
(
s EMPLOYMENT RECORD
. Company Position Dates 1972 to Present U.S. Testing Co.,'Inc.
Quality Assurance Engineer 1970 to 1972 Ecological & Environmental Project Manager Improvement Inc.
1940 to 1970 Curtiss Wright Corp.,
Purchasing, Curtiss Division Industrial Relation @
Metallurgical PROFESSIONAL EXPERIENCE U.S. Testing Co.,Inc.
Assigned to Indian Point Nuclear Generating Plant -
Con Edison.
Responsible for quality. control of operations to verify and document that established procedures were followed.
.[
(_.
s 9
i UN ID STATES TESTING COMPAt INC.
g Assigned to Three Mile Island Nuclear Generating Plant - Met. Ed & Jersey Central Power & Light
(~
as Land QC/QA Vendor Surveillance Co-ordinator responsible for assignment and direction of Vendor Surveillance QC Representatives. Liason with j"v Engineering, Purchasing, Q.A. Engineering and Expediting Departments.
s Ecological & Environmental Improvement Co.
j
~
Project Manager:
Dredging Operation, Clearing, cleaning and deepening a 12 mile section of the. Pompton River, New Jersey Responsible for procuring, scheduling and directing hevi-duty construction equipment and manpower. Verify specification and contract obligations were being met.
Curtiss Wright Corporation, Curtiss Division Outside Expeditor & Buyer-Purchasing liason representatiTe J
for vendors and sub-contractors.
Responsible for in-vestigating, resolving and insuring positive corrective action of manufacturing and quality problems.
Exanined facilities, evaluated capabilities and exchanged information' to enable them to strictly adhere to our Quality and Delivery requirements.
Safety Engineer-Plan, control, supervise all functions necessary to maintain a complete Industrial Accident Prevention program in accordance with existing Federal and State Rules and Regulations.
Test Engineer -Metallurgical Laboratory-Responsible for testing of all materials received, both raw and finished to determine their compliance with applicable specifications.
Maintained and calibrated cll physical test equipment.
Held Air Force Supervisor's Inspection Certificate for Magnetic Particle Inspection, established magnaflux & Radiography Procedures.
D 9.
?#i UNITED STATES. TESTING COMPANY, ING.
PROFESSIONAL RECORD WALCUTT, ANDREW J.
s
.?.
Quality Assurance Engineer
)
ACADEMIC TRAINING _
l Florida Institute of Technology Graduate 1973~
B.S.
In Oceanography with Minor in Mechanical Engineering EMPLOYMENT RECORD Dates Company Position 1973 to Present U.S.
Testing Company,inc.
Q.A. Engineer
~
1967 - 1973 Various Companies Supporting Col PROFESSIONAL EXPERIENCE United States Testing Company,Inc.
Assigned to Boston Edison's Pilgrim Nucicar Station during maintenance outage.
Duties involved surveillance of mainte-nance operations for compliance with approved procedures and inspection check points.
Assigned to Con Edison's indian Point Nuclear Station 1 & 2 during routine maintenance and repair operations.
Surveillance scope included refueling operation, fuel inspection, welding procedures, welder qualification, fitup certifications and documentation.
(
9 t
9