/tr ( y-l7p TMd i
,-m
,e.-
A
- e. n n n)u u...,
%as.e Giu f
i t,,. = m :n t,
/).
P ir ive
\\
/
'O.
/
f:Ui!jri.g:f 3 --
si.ph.. u. u...ii
-Q a p
v,c, e,..isent General Offices: 212 West Mecnigen Avenue. Jackson. Michigan 49201 April 24, 1975 sis-67-75 Dr. Donald F. Knuth Office of Inspection and Enforcement US Nuclear Regulatory Co= mission Washington, DC 20545
Dear Dr. Knuth:
In accordance with Condition 4 of Memorandum and Order AIAB-106 dated March 26, 1973, and Amendment No 1 to the Midland Plant Construction Permit, enclosed are two (2) copies of the non-(3
)
conformance reports fp;Marchio1%~ Tuis report cons. sts of' i
2 copies of Bechtel Nonconformince Reports, Quality Audit Findings, and Management Corrective Action Reports written or closed during I.
the month; all sheets from the Bechtel Nonconformance Report Leg and Status Book which reficct cpen Bechtel H2's and Consu=ers Power Company Honconformance Reports written or closed during the month.
Yours very truh,
G
- r. J -C-
- we.
O r
i 800618o.
9 '3 s
I
~
'T NONC'ONFORMANCE REPORT (CONT'D)
- i. rase 2 or 2 299 f.-
,,, u ca no-Block 19 Continued
/
Qty Size Material Packing Slip #
MRR #
Insuection' Plan #
[.-
t f
260 7/8 x 2 Bolts w/ nuts V666-R-27 AE 6
C-18-R-17 Rnv. O f
L 200 7/8 X 2A Bolts w/nuto V66h-R-136 AEO-7.6 0-38-R-37 Rnv. o
/
200 7/8 X 2 3/h Boltsw$uts V66h-R-136 AEO-7h6 C-18-R-37 Rev. O f
1h00 7/8 X 24 Bolts $/ nuts V863-209 AE0-776 0-18-R-39 Rev, O f
626 7/8 X 3F Bolts w/ nuts V863-209 AE0 -776 0-18-R-19 Rnv. 0 1200 7/8 X 2A Bolts w/ nuts V665-R-92 AEO-776 C-18-R-19 Rev. O
~
7/8 X 3 Bolts w/ nuts v665-R-92 AEO-776 C-38-R-39 Rev. 0 175 525 7/8 X 3 Bolts w/ nuts V1016-R-70 AEO-776 C-38-R-39 Rev. O 176 7/8 X 31 Bolts w/ nuts V1016-R-70 AEO-776 C-38-R-19 Rev. 0
/
176 78X3 Bolts w/nuto V66h-R-93 AEO-776 C-18-R-19 Rnv. O
~
900 7/8 X 21 Bolts w/ nuts V1016-33 AEO-790~
C-38-R'-h1 Rov. 0 800 7/8 X 2}
Bolts v/ nuts V1016-33 AE0-790 0-38-R-h1 Rev'O o
675 7/8 X 2t Bolts w/ nuts V665-61 AEO-79 0 -
C-38-R-h1 Rev. 0 900 7/8X2t Bolts w/ nuts V863-16 AE0-790 C-38-R-h1 Rev. O Nonconformance noted during receipt inspection.
"Q," numbers 1.101 and 1.201. Unita 1 & 2.
//h Hold tags applied.
,- M 4 = L
'[
o c.
b H ORIGINATOR J