ML19329E595

From kanterella
Jump to navigation Jump to search
Forwards Magnetic Tape Re hr-by-hr Meteorological Data for Mar 1975-Feb 1977,in Response to NRC
ML19329E595
Person / Time
Site: Midland
Issue date: 03/30/1978
From: Howell S
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To: Boyd R
Office of Nuclear Reactor Regulation
References
HOWE-39-78, NUDOCS 8006160380
Download: ML19329E595 (4)


Text

-.

e l-

/

CC3UID3i3 I.Wni

'/

4... w 3 4

Stephen H. Howell 4 a.. :* S t,

i Vice President General of fices: 1945 West Parnall Road, Jackson, MicNgan 49201

  • Area Code 517 788-0453 March 30, 1978 Hove-39-78

,W~-S I r s;?

/((5I'/ -

Director of Nuclear Reactor Regulation

,,'S[,,[.[f[g,

'q Attn: Mr Roger Boyd, Director d,

Division of Project Management

,,,J.

s/j p..

US Nuclear Regulatory Cocmission

u. s.,,, ';'

,7 p

Washington, DC 20555

- (11 MIDLAND PROJECT i,'..

Oo DOCKET H0 50-329, 50-330 N's' METEOROLOGICAL DATA TAPE FILE: 0505.2 SERIAL:

5070 Enclosed is a magnetic tape containing hour-by-hour meteorological data from Consumers Power Company's 91.5 meter meteorological tower for the period March 1, 1975 through February 28, 1977 This =agnetic tape is being provided as requested by Mr D B Vassallo's letter of April 22, 1977 to Mr S H Howell.

The data is presented in the standardized for=at as recom= ended by the refer-enced letter.

The tape is 9 track, fixed block, density 1600 BPI, record length 160, block size 3200. The for=at is given in Enclosure 1.

Although all the data collected from the 91.5 meter tower are provided on the magnetic tape, Consumers Power Co=pany used only the 10 and 60 meter vind speed and directions and the 10 to 60 meter delta temperature to calculate atmospheric diffusion characteristics at the Midland site.

Q ~

  • b -Q

' 'N SHH/jbg i [q

-pgd 1

i JfO

@f 8006160

MAG 1CTIC TAPE METEOIOLOGICAL DATA Consumers Power Company 91.5 Meter Tower IOCATIOti: Midland Nuclear Plant, Midland, Michigan DATE OF DATA RECORD: March 1, 1975 - February 28, 1977 I6 Identifier (can be ariything) "CPMNPP" I2 Year I3 Julian Day I4 Hour (on 24 hr clock)

ACCURACY FS.1 Upper Measurements: Level = meters 91.5 F5.1 Wind Direction (degrees)

F5.1 Wind Speed (meter /sec)

F5.1 Sigma Theta (degrer.,)

-blank F5.1 Ambient Temperature ( C)

F5.1 Moisture: Dev Point ( C)

PS.1 Other:

Blank F5.1 Intermediate Measurements: Level = meters 60.0 F5.1 Wind Direction (degrees)

F5.1 Wind Speed (meters /sec)

~

F5.1 Sigma Theta (degrees)

F5.1 Ambient Temperature (o C) s.

i j

_ FS.1 Moisture: Dev Point ( c)

F5.1 Other:

Elank l

e O

e

+

. o.,,-

Enclosure l PS.1 _

Iower Measurements: Level meters 10.0

=

F5.1 Wind Direction (degrees)

F5.1 Wind Speed (ceters/sec)

F5.1 Sigma Theta (degrees)

F5.1 AThient ivmperature ( oC)

F5.1 Fbisture: Dev Point ( C)

FS.1 Other: Blank F5.1 Temp Diff (Upper-Lower) ( C/100 meters) tit (91.5-10)

F5.1 7b.mp Diff (Upper-Intermediate) (("C/100 meters)

ET 91.5-60)

F5.1 Temp Diff (Intermediate-Lower) ( 60-10)

C/100 meters)

A T(

F5.1 Level, ceters 40.0 FS.2 Wind speed (=/see) t F5.1

. Ambierrt temperature ( C)

F5.1 Other: Dew Point ( C)

F5.1 Other: Temp. difference (40 meter-10 meter)

(C/100ceters) e 4

O I

O Gf

~

REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

DISTRIBUTION FOR INCOMING MATERIAL 30 REC: BOYD R S ORG: HOWELL S H DOCDATE: 03/30/78 NRC CONSUMERS PWR DATE RCVD: 03/31/78 DOCTYPE: LETTER NOTARIZED: NO

SUBJECT:

COPIES RECEIVED LTR 1 ENCL 1 RESPONSE TO NRC REQUEST OF 04/22/77.

FORWARDING MAGNETIC TAPE CONTAINING HOUR-BY-HOUR METEOROLOGICAL DATA FROM APPLICANT"S 91.5 METER METEOROLO TOWER FOR THE PERIOD 03/01/75 THROUGH O2/28/77.

NOTE: TAPE ADVANCED TO DARL HOOD W/ATT SUPPORTING IN PLANT NAME: MIDLAND - UNIT 1 REVIEWER INITIAL:

X.

MIDLAND - UNIT 2 DISTRIEUTER INITI AL:

o*o**************

DISTRIBUTION OF THIS MATERIAL IS AS FOLLOWS ******************

PSAR/FSAR AMDTS AND RELATED CORESPONDENCE (DISTRIBUTION CODE BOO 1)

FOR ACTION:

ASST DIR VASSALLO**LTR ONLY BR CHIEF VARGA**LTR ONLY PROJ MGR HOOD **W/ ENCL LIC ASST SERVICE **LTR ONLY FOR INFO:

MOORE **W/ ENCL REGAN**W/ ENCL FOR INFO:

E g ru y "'--"^'-

KREUTZER **W/ ENCL INTERNAL:

I NRC POR**W/ ENCL I & E**W/2 L

OELD**LTR ONLY P.

COLLINS **W/ ENCL HOUSTON **W/ ENCL HELTEMES**W/ ENCL CASE **LTR ONLY MIPC**LTR ONLY KNIGHT **LTR ONLY BOSNAK**W/ ENCL SIHWEIL**W/ ENCL PAWLICKI**W/2 ENCL ROSS**LTR ONLY NOVAK**W/ ENCL ROSZTOCZY**W/ ENCL CHECK **W/ ENCL TEDESCO**LTR ONLY BENAROYA**W/ ENCL LAINAS**W/ ENCL IPPOLITO**W/ ENCL F.

ROSA **W/ ENCL GAMMILL**W/4 ENCL VOLLMER**LTR ONLY BUNCH **W/ ENCL J.

COLLINS **W/ ENCL KREGER**W/ ENCL KIRKWOOD**W/ ENCL EXTERNAL:

LPDR'S MIDLAND, MI**W/ ENCL TIC **W/ ENCL NSIC**W/ ENCL ACRS CAT A**W/16 ENCL i

l DISTRIBUTION:

LTR 60 ENCL 50 SIZE: IP+6P CONTROL-NERa 7GO,;3C,7^

J eN ' (

oc*o*******************************

THE END

                                                    • d

.