m General Offices: 212 West Michsgan Avenue. Jackson, Micnigen 492. Area Code 517788 05S0 Uove=ber 10, 1976 Director of Huclear Reactor Regulatton k
Attention:
Mr. Roger Boyd, Director 7,'s I C Division of Project Management v.'
US Nuclear Regulatory Commission T;p
-dj
~
Washington, DC 20555 4
[
k
';/
MIDLAND PROJECT T
DOCKET NUMBERS 50-329, 50-330 0
8, QA REGULATORY GUIDE RESPONSES FILE: 0505 2 SERIAL: 2937 Pursuant to conversations with the staff on November 10, 1976, Page 12 of the proposed " Quality Assurance Program" description has been revised.
Please insert the attached revised Page 12 into the " Quality Assurance Program" description which vas submitted with our November 9,1976 letter.
. LL 1
!C %
d' R. C. Bauman cc, Project Engineer fjU, / g m
8-i RCB/HWS/jmb
~
" 8 %c.,.,
c,,..
%I[
-r
'N
/h 1:'.Gr 8006160 3
[
6"
'7 i
- 3) Table B required In-Process Tests. This table requires that the c'ompressive strength of grout be in-process tested 0a113 d ur ' ng e
production to the requirements of ASTM C 109 The folloving alternates to the testing of grout vill be implemented:
a) Batch Plant Mixed Grout The specifications require that each class of concrete has a companion grout mixture for use on construction joints, buttering pump lines and such other applications as shown on the drawings. As appropriate to the concrete mix, the Erout mix is specified to be the concrete mix *elthout the addition of coarse aggregate,leavin6 the cement, pozzolen. sand (fine aggregate 3/8 inch or less) and admixtures in the same ratio as before and enough veter to provide.the desired consistency. b2t not exceeding the maximum veter/(cement + pozzolan) ratio established for the concrete mix. Since this vill produce a grout at lesst as strong as its companion concrete (due to the high cement content per cubic yard), testing of all the materials used in manufactarin6 Srout is done as part of the concrete in process testing program, and this accomplishes satisfactory quality control of the grout.
b) Premixed Grou't Factory packaged grout which requires addition of vater and 3 mixing in accordance with the manufacturer's instructions vill be tested in accordance with ASTM C 109 for each lot purchased as a quality control check on the factory's production. Since the project specifications require proper storace to prevent deterioration, there is no reason to require daily testing.,
t 0
t t
I
NRC'F. r.u 195
's u.O. NUCLE AR f.E GULAToa Y C'"WISSION enn r
- '"aFR 4,47;l
{% ' }}O s NRC DISTRIBUT JN FoR PART 50 DOCKET MATERIAL ~ To: Mr Boyd ' ~ FROM: Consumers Power Company DATE OF DOCUME Jackson, Michigan R C Bauman DATE RECEIVED CLETTER ONoroRizEo PROP INPUT FORM NUMBER oF COPIES RECEIVED CoRIGIN AL SUNCLASSIFIED OCoPv one signed oesCRiprioN l ENCLOSU RE Ltr trans the following': Revised Pg r/12 to their 11-9-76 submittal entitled " Quality Assurance Program"..... (1 cy enc 1 rec'd) PLANT NAME: ^'w l Midland 1 & 2 t SAFETY FOR ACTION /INFORMATION ENVTRn 11-20-76 ehf / A33IG;rF.D AU: Vd.s S e //dp ASSICNrD AD! l l / BRANCH CHIEF: Vd e 44 BRANCH CMTEF= / PROJECT MANAGER: ' # o "u.e4. / / PROJECT MANAGERt } f LIC, ASST.: S e s, v e e <, LIC. ASST.? I. INTERNAL DISTRIBUTION f__ REC _FILF J SYSTEMS SAFETY PTANT SYSTrus SITE SAFETv & Y__ pta., rUR I!EINEMAN TrnFs('n ENVIRO ANALYSIS i / I & E / s) SCl!ROEDER BENAROYA DENTON & M"TIFR OELD IAlUAS COSSICK & STAFF ENGINEERING IPPOLITO ENVIRO TECH _ / MIPC MACCARRY KIRKWOOD ERNST / CASE KNIGHT BALLARD ltANAUER SIHWEIL OPERATING REACTORS SPANCYER _JEIU.ESS PAWLICKI STELLO sTTE TF('M_ ,_,J_ROJECT MANAGEFENT REACTOR SAFETY OPERAUNC TECH. CAINTLL BOYD ROSS EISEjHlUT STEPP Z2. CotuNS Nov^x SHA0 HurmN [JIOUS. TON ROSZTOCZY BAER [ PETERSON CllECK BUTLER SITE _ANALY3IS \\ MELTZ CRIMES VOLL}!ER l / llELTEMES T} AT_& I EUNCll SKOV110LT ~ SALTZMAN .ImCOLLINS Yrt oug t., ~iUTitEitd IrnFCER l ~ EXTEltN AL OISTHluuTION CONI flOL NUMBE R /LPDR: fM ed lgnd, #7 p N5Tl iD: BROOKHAVEN_NAT LAB REG. VIF. ULRIKSON_(ORNL) M/ / TIC: _ ? NSIC: LA.PDR ~~ ASLB; CONSULTANTS ff g 8 / 7ACaS((CYS - wsrxMiu~AF3~cKr ty_ _H_- z. 0 - 2 4' .L_ NitC t OHM 1993 (g.M3}}